EAGLE IRRADIATIONS EXTERNAL Analysis Students Workshop Shift Plans
GAMMA-ONLY NEEDLE NEEDI COULEX PLUNGER GENERAL
HIL102-128Cs HIL087-176Pt Nd148_2 176Pt HIL109-172Os HIL124-128Cs HIL061 Nd148 HIL106-119Cs HIL097-118Xe HIL099-134Sm April16 xdaq
  HIL099-134Sm  ELOG logo
Message ID: 161     Entry time: Wed Mar 8 11:42:14 2023
Author: IK 
Type: Problems 
test:  
Category: General 
Subject: Run 49 

Counting rates continued to increase (det4 > 3kHz). Beam current looked fine on the beam dump, but beam is fluctuating, and can reach 2nA on the collimator.  Asked for improved focusing.

Attached screenshots and Ge spectra from before changing anything.

 

run control = 49

run data = /onlineNEDA_00/xData/hil099/run_0049_08-03-2023_09h31m08s/needleRU_i49_0049_0020.caendat

RU =  13.3 MB/s

LF =   6.15MB/s

plunger:

plunger run = 603

actual distance =  382.7 um

supposed distance = 382.7 um

micrometer =   385.9 um

position =  150.0 um

voltage =  2.146 V

 

Beam dump 0.7 nA

Collimator ~1.5-2nA when the generator retunes itself (prob the beam gets defocused at those moments)

 

 

 

 

 

Attachment 1: Screenshot_2023-03-08_11-38-47.png  49 kB  | Hide | Hide all | Show all
Screenshot_2023-03-08_11-38-47.png
Attachment 2: Screenshot_2023-03-08_11-38-19.png  39 kB  | Show | Hide all | Show all
Attachment 3: Screenshot_2023-03-08_11-37-37.png  36 kB  | Show | Hide all | Show all