Entry time:
Tue Feb 24 16:07:25 2026
Author
*
:
Type
*
:
- please select -
Runs
Problems
Problem Fixed
Other
test:
Category:
- please select -
General
Hardware
Software
Network
Other
tests
mechanics
DIAMANT
Beam
Data analysis
Target
Subject:
<p>At about 12:00, 13/03/2023 (about 17 hours after the beam was stopped), a measurement of activity of the beam line was performed using FH 40G-L10 meter.</p> <p>Radioctivity run 65 stopped before the measurement, radioactivity run 66 started after the measurement</p> <p>Background level 120 ns/h</p> <p>Target, stopper, the forward half of the target chamber - dismounted.</p> <p>Approximate distance from the target position (upstream), approximate activity</p> <p>10 cm 500 ns/h</p> <p>25 cm 420 ns/h</p> <p>35 350 ns/h</p> <p>40 350 ns/h</p> <p>50 200 ns/h</p> <p>75 170 ns/h</p> <p> </p> <p> </p>