  107   Mon Mar 6 09:53:06 2023 OSTProblems BeamBeam dump decreased 2.5 nA to 1.5 nA- stopped run 41

9:20 to 9:50 am beam current stayed 2.5 nA . After 9:50 am decrease 1.5 nA

  108   Mon Mar 6 10:02:47 2023 OSTProblem Fixed GeneralNew run started 42

RUN CONTROL = 42

Data =/onlineNEDA_00/xData/hil099/run_0042_06-03-2023_09h54m24s/needleRU_i42_0042_0000.caendat

           /onlineNEDA_00/xData/hil099/run_0042_06-03-2023_09h54m24s/needleLF_i41_0042_0000.adf

RU =   6.01 MB/s

LF =   3.32 MB/s

Plunger ;

Plunger run = 105

Supposed Dist= 242.7 um

Micrometer =  246.1 um

Position =   9.9  um

Actual distance = 242.6 um

Voltage =  3.809  V

Beam dumb =  1.5 nA

  109   Mon Mar 6 10:56:46 2023 OSTRuns General 

RUN CONTROL = 42

Data =/onlineNEDA_00/xData/hil099/run_0042_06-03-2023_09h54m24s/needleRU_i42_0042_0004.caendat

 

RU =   5.69 MB/s

LF =   3.37 MB/s

Plunger ;

Plunger run = 115

Supposed Dist= 242.7 um

Micrometer =  246.4 um

Position =   10.3  um

Actual distance = 243 um

Voltage =  3.801  V

Beam dumb =  1.5 nA

  110   Mon Mar 6 12:10:49 2023 OSTRuns General 

RUN CONTROL = 42

Data = /onlineNEDA_00/xData/hil099/run_0042_06-03-2023_09h54m24s/needleRU_i42_0042_0010.caendat

RU =   5.46 MB/s

LF =   3.20 MB/s

Plunger ;

Plunger run = 127

Supposed Dist= 242.7 um

Micrometer =  245.9 um

Position =   10.4  um

Actual distance = 243 um

Voltage =  3.8  V

Beam dumb =  1.5 nA

Collimater=1.25 nA

  111   Mon Mar 6 14:01:48 2023 OSTRuns General 

RUN CONTROL = 42

Data =/onlineNEDA_00/xData/hil099/run_0042_06-03-2023_09h54m24s/needleRU_i42_0042_0019.caendat

RU =   5.12 MB/s

LF =   3.20 MB/s

Plunger ;

Plunger run = 145

Supposed Dist= 242.7 um

Micrometer =  245.5 um

Position =   10  um

Actual distance = 242.7 um

Voltage =  3.812  V

Beam dumb =  1.5 nA

Collimater=1.25 nA

  112   Mon Mar 6 15:48:23 2023 OSTRuns General 

RUN CONTROL = 42

Data =/onlineNEDA_00/xData/hil099/run_0042_06-03-2023_09h54m24s/needleRU_i42_0042_0026.caendat

RU =   5.24 MB/s

LF =   3.19 MB/s

Plunger ;

Plunger run = 162

Supposed Dist= 242.7 um

Micrometer =  245.5 um

Position =   10  um

Actual distance = 242.7 um

Voltage =  3.813  V

Beam dumb =  1 nA

Collimater=1 nA

  113   Mon Mar 6 17:19:24 2023 OSTProblems Beambeam unstable and a little high

16:30 beam increased 5 mb/s to 9 mb/s and stayed 1 hour 9 mb/s

17:10 beam fixed. stable

  114   Mon Mar 6 17:27:42 2023 OSTRuns General 

RUN CONTROL = 42

Data =/onlineNEDA_00/xData/hil099/run_0042_06-03-2023_09h54m24s/needleRU_i42_0042_0035.caendat

RU =   5.43 MB/s

LF =   3.10 MB/s

Plunger ;

Plunger run = 179

Supposed Dist= 242.7 um

Micrometer =  245 um

Position =   9.7  um

Actual distance = 242.4 um

Voltage =  3.822  V

Beam dumb =  1 nA

Collimater=0.5 nA

  127   Tue Mar 7 09:18:01 2023 OSTProblems Beamrun number 44 crashed and local filter turned red-but data saved

9:08 local filter turned red. Both .caendat and   LF .adf files still incrementing. Stopped run 44, started run 45, looks OK.

 

 

Attachment 1: run_control_7mar2023_0910.png
run_control_7mar2023_0910.png
  128   Tue Mar 7 09:20:53 2023 OSTProblem Fixed Beamrun 45 start-local filter turn green

I started run 45, and local filter turn green everything is ok.

  129   Tue Mar 7 09:24:53 2023 OSTRuns General 

run control = 45

run data =/onlineNEDA_00/xData/hil099/run_0045_07-03-2023_09h14m17s/needleRU_i45_0045_0000.caendat

RU =  6.92 MB/s

LF =   3.71 MB/s

plunger:

plunger run = 340

actual distance =  282.7 um

supposed distance = 282.7 um

micrometer =   285.5 um

position =  50.1 um

voltage =  2.967 V

Beam dump =  1 nA

Collimater=  0.5 nA

  130   Tue Mar 7 09:41:44 2023 OSTProblems Softwarenumber_Ge_15 dedector not taking data

after run 45 I reset all spectrums and number_Ge_15 dedector not taking data.

i check the fans_monitor_scaler (EAGLE_array_monitor) monitor and number 15 Ge, number ACS 5 never change the color just staying white there is a problem.

 

 

  131   Tue Mar 7 09:56:07 2023 OSTProblems mechanicsBeam stopped and operators controlling number 15_Ge dedector.
  132   Tue Mar 7 11:19:54 2023 OSTRuns General 

run control = 45

not fixed number 15_Ge dedector and number 5 anticompton.

run data =/onlineNEDA_00/xData/hil099/run_0045_07-03-2023_09h14m17s/needleRU_i45_0045_0011.caendat

RU =  6.52 MB/s

LF =   3.57 MB/s

plunger:

plunger run = 358

actual distance =  282.8 um

supposed distance = 282.7 um

micrometer =   285.3 um

position =  50.1 um

voltage =  2.965 V

Beam dump =  1 nA

Collimater=  0.5 nA

  133   Tue Mar 7 12:50:52 2023 OSTRuns General 

run control = 45

not fixed number 15_Ge dedector and number 5 anticompton.

run data =/onlineNEDA_00/xData/hil099/run_0045_07-03-2023_09h14m17s/needleRU_i45_0045_0019.caendat

RU =  6.42 MB/s

LF =   3.65 MB/s

plunger:

plunger run = 373

actual distance =  283 um

supposed distance = 282.7 um

micrometer =   285.2 um

position =  50.3 um

voltage =  2.962 V

Beam dump =  1 nA

Collimater=  0.5 nA

  134   Tue Mar 7 13:51:17 2023 OSTRuns General 

run control = 45

not fixed number 15_Ge dedector and number 5 anticompton.

run data =/onlineNEDA_00/xData/hil099/run_0045_07-03-2023_09h14m17s/needleRU_i45_0045_0025.caendat

RU =  6.54 MB/s

LF =   3.60 MB/s

plunger:

plunger run = 384

actual distance =  283 um

supposed distance = 282.7 um

micrometer =   285.2 um

position =  50.3 um

voltage =  2.963 V

Beam dump =  1 nA

Collimater=  0.5 nA

  139   Tue Mar 7 15:12:06 2023 OSTProblems Softwarerun 45 stopped

14:30 pm to 15:00 run 45 crashed and stopped

  140   Tue Mar 7 15:14:29 2023 OSTProblem Fixed SoftwareRun 46 started-15_Ge and number 5 anticompton working now.

VME crate with CAEN digitizers was rebooted.

Run 46 started, number 15_Ge and number 5 anticompton dedector working now.

 

  141   Tue Mar 7 16:06:16 2023 OSTRuns General 

run control = 46

run data =/onlineNEDA_00/xData/hil099/run_0046_07-03-2023_15h08m38s/needleRU_i46_0046_0004.caendat

RU =  6.51 MB/s

LF =   3.44 MB/s

plunger:

plunger run = 405

actual distance =  283 um

supposed distance = 282.7 um

micrometer =   285.9 um

position =  50 um

voltage =  2.966 V

Beam dump =  0.7 nA

Collimater=  0.5 nA

  171   Wed Mar 8 19:01:49 2023 OSTRuns Generalbeam current was very low and beam increased after this entry

run control = 49

run data = /onlineNEDA_00/xData/hil099/run_0049_08-03-2023_09h31m08s/needleRU_i49_0049_0064.caendat

RU =  5.75 MB/s

LF =   3.50 MB/s

plunger:

plunger run = 676

actual distance =  382.8 um

supposed distance = 382.7 um

micrometer =   384.9 um

position =  150.4 um

voltage =  2.146 V

 

Beam dump 0.7

ELOG V3.1.5-fc6679b