EAGLE IRRADIATIONS EXTERNAL Analysis Students Workshop Shift Plans
GAMMA-ONLY NEEDLE NEEDI COULEX PLUNGER GENERAL
HIL102-128Cs HIL087-176Pt Nd148_2 176Pt HIL109-172Os HIL124-128Cs HIL061 Nd148 HIL106-119Cs HIL097-118Xe HIL099-134Sm April16 xdaq
  HIL099-134Sm, Page 8 of 14  ELOG logo
ID Date Authordown Type test Category Subject
  52   Fri Mar 3 10:21:18 2023 IP. KWLRuns Generalbeam intensity back to 1.25 enA at the beam dump

we increased beam intensity to 1.25 enA (readout at the beam dump)

  56   Fri Mar 3 13:43:56 2023 IP. KWLRuns  511 annihilation and 279 Au lines in Ge rings

The counting rate in 511 keV line for sum of the Ge detectors placed at 101, 117 and 143 degrees (with approved ACS). The largest intensity is visible for Ge at 143 degrees, lowest for 101 deg.

=============================== RING 101

Integration in spectrum user_ge_ring101_acceptedACS_clone.spc

RESULT : 3895

=============================== RING 117

Integration in spectrum user_ge_ring117_acceptedACS.spc

RESULT : 9392

=============================== RING 143

Integration in spectrum user_ge_ring143_acceptedACS.spc

RESULT : 15767

 

The Coulex of 197Au (279.5 keV ) line is visible in all rings with a comparable intensity:

=============================== RING 101

Integration in spectrum user_ge_ring101_acceptedACS_clone.spc

RESULT : 12491

=============================== RING 117

Integration in spectrum user_ge_ring117_acceptedACS.spc

RESULT : 11443

===============================RING 143

Integration in spectrum user_ge_ring143_acceptedACS.spc

RESULT : 10460

 

 

 

Attachment 1: ge_rings101_117_143_acceptedACS_gold_line_279keV.png
ge_rings101_117_143_acceptedACS_gold_line_279keV.png
Attachment 2: ge_rings101_117_143_acceptedACS.png
ge_rings101_117_143_acceptedACS.png
  57   Fri Mar 3 13:54:41 2023 IP. KWLRuns Generalbeam energy measurement

beam stop due to the beam energy measurement

The beam energy: ~145 MeV

  147   Tue Mar 7 23:39:52 2023 IP, KSRuns Generalrun 46 stopped

Run 46 - stopped

  • Run number: 46
  • Start time: Tue Mar 7 15:09:06 2023
  • Stop time: Tue Mar 7 23:38:07 2023
  148   Tue Mar 7 23:54:05 2023 IP, KSRuns General 

run control = 47

run data = /onlineNEDA_00/xData/hil099/run_0047_07-03-2023_23h42m03s/needleRU_i47_0047_0000.caendat

RU =  4.47 MB/s

LF =   3.26 MB/s

plunger:

plunger run = 484

actual distance =  282.8 um

supposed distance = 282.7 um

micrometer =   285.2 um

position =  50.1 um

voltage =  2.965 V

 

Beam dump =  0.7 nA

Collimater=  0.5 nA

  53   Fri Mar 3 11:37:25 2023 IPRuns General 

plunger run # 230

Beam dump 1.2  enA (given by operators) * 7 (following entry ID#39) = 8.4 enA

Collimator   0.6  enA

Run Data =/onlineNEDA_00/xData/hil099/run_0035_03-03-2023_00h04m26s/needleRU_i35_0035_0047.caendat

RU : 5.88 MB/s

LF : 8.35 MB/s

Supposed Distance = 10 um

position of the target = 10.2 um

micrometer = 8.8 um

Voltage = 7.94 V

  54   Fri Mar 3 11:48:29 2023 IPRuns Generalbeam stopped

The beam is gone.

  55   Fri Mar 3 12:11:24 2023 IPRuns General 

the beam comes back.

  58   Fri Mar 3 14:22:12 2023 IPRuns General 

the beam comes back. The run 35 is still going.

 

plunger run # 257

Beam dump .... enA (given by operators) * 7 (following entry ID#39) = ... enA

Collimator  ....   enA

Run Data = /onlineNEDA_00/xData/hil099/run_0035_03-03-2023_00h04m26s/needleRU_i35_0035_0059.caendat

RU : 6.18 MB/s

LF : 8.44 MB/s

Supposed Distance = 10 um

position of the target = 10.2 um

micrometer = 8.8 um

Voltage = 7.94 V

 

  142   Tue Mar 7 17:45:18 2023 IPRuns General 

run control = 46

run data = /onlineNEDA_00/xData/hil099/run_0046_07-03-2023_15h08m38s/needleRU_i46_0046_0013.caendat

RU =  6.10 MB/s

LF =   3.26 MB/s

plunger:

plunger run = 422

actual distance =  282.6um

supposed distance = 282.7 um

micrometer =   284.9 um

position =  49.9 um

voltage =  2.968 V

Beam dump =  0.7 nA

Collimater=  0.5 nA

  143   Tue Mar 7 19:24:25 2023 IPRuns General 

run control = 46

run data = /onlineNEDA_00/xData/hil099/run_0046_07-03-2023_15h08m38s/needleRU_i46_0046_0022.caendat

RU =  6.22 MB/s

LF =   3.34 MB/s

plunger:

plunger run = 439

actual distance =  282.5um

supposed distance = 282.7 um

micrometer =   284.9 um

position =  49.8 um

voltage =  2.97 V

Beam dump =  0.7 nA

Collimater=  0.5 nA

  144   Tue Mar 7 20:42:03 2023 IPProblems Beambeam unstable

There was a problem with the beam from 20:19 to 20:30.

Now it is fine.

  145   Tue Mar 7 20:45:13 2023 IPRuns General 

run control = 46

run data =/onlineNEDA_00/xData/hil099/run_0046_07-03-2023_15h08m38s/needleRU_i46_0046_0028.caendat

RU =  4.9 MB/s

LF =   3.14 MB/s

plunger:

plunger run = 452

actual distance =  282.4 um

supposed distance = 282.7 um

micrometer =   284.7 um

position =  49.7 um

voltage =  2.971 V

Beam dump =  0.7 nA

Collimater=  0.5 nA

  146   Tue Mar 7 21:55:45 2023 IPRuns General 

run control = 46

run data = /onlineNEDA_00/xData/hil099/run_0046_07-03-2023_15h08m38s/needleRU_i46_0046_0034.caendat

RU =  4.78 MB/s

LF =   3.10 MB/s

plunger:

plunger run = 464

actual distance =  282.8 um

supposed distance = 282.7 um

micrometer =   285.1 um

position =  49.9 um

voltage =  2.965 V

Beam dump =  0.7 nA

Collimater=  0.5 nA

  188   Thu Mar 9 16:25:57 2023 IPRuns Generalrun 50 stopped

run 50 - stopped

  •  
  • Run number: 50
  • Start time: Thu Mar 9 00:50:57 2023
  • Stop time: Thu Mar 9 16:22:37 2023
  191   Thu Mar 9 19:58:02 2023 IPRuns General 

run control = 51

run data = /onlineNEDA_00/xData/hil099/run_0051_09-03-2023_16h25m16s/needleRU_i51_0051_0018.caendat

RU =  5.93 MB/s

LF =   3.44 MB/s

 

plunger:

plunger run = 927

actual distance =  533.3 um

supposed distance = 532.7 um

micrometer =   533.0 um

position =  300.0 um

voltage =  1.656 V

 

Beam dump: 1 nA

Colimator :  0.6 enA

  192   Thu Mar 9 21:20:06 2023 IPRuns General 

run control = 51

run data = /onlineNEDA_00/xData/hil099/run_0051_09-03-2023_16h25m16s/needleRU_i51_0051_0026.caendat

RU =  6.23MB/s

LF =   3.56 MB/s

 

plunger:

plunger run = 940

actual distance =  532.2 um

supposed distance = 532.7 um

micrometer =   533.0 um

position =  299.5 um

voltage =  1.659 V

 

Beam dump: 1 nA

Colimator :  0.6 enA

  193   Thu Mar 9 22:32:01 2023 IPRuns General 

run control = 51

run data = /onlineNEDA_00/xData/hil099/run_0051_09-03-2023_16h25m16s/needleRU_i51_0051_0032.caendat

RU =  6.12 MB/s

LF =   3.42 MB/s

 

plunger:

plunger run = 952

actual distance =  533.2 um

supposed distance = 532.7 um

micrometer =   533.7 um

position =  300.5 um

voltage =  1.656 V

 

Beam dump: 1 nA

Colimator :  0.6 enA

  206   Fri Mar 10 16:14:19 2023 IPOther GeneralGe - the rate is higher

From 13:00 the rate of the Ge [the chanel 4] is a bit higher (~2.15 kHz). And also the rate of other detectors.

 

Attachment 1: Screenshot_2023-03-10_16-10-45.png
Screenshot_2023-03-10_16-10-45.png
  207   Fri Mar 10 16:17:57 2023 IPRuns Generalrun 52 - stopped

run 52 - stopped

 

  • Run number: 52
  • Start time: Fri Mar 10 01:19:56 2023
  • Stop time: Fri Mar 10 16:16:25 2023
ELOG V3.1.5-fc6679b