EAGLE IRRADIATIONS EXTERNAL Analysis Students Workshop Shift Plans
GAMMA-ONLY NEEDLE NEEDI COULEX PLUNGER GENERAL
HIL102-128Cs HIL087-176Pt Nd148_2 176Pt HIL109-172Os HIL124-128Cs HIL061 Nd148 HIL106-119Cs HIL097-118Xe HIL099-134Sm April16 xdaq
  HIL099-134Sm, Page 9 of 15  ELOG logo
ID Date Authordown Type test Category Subject
  58   Fri Mar 3 14:22:12 2023 IPRuns General 

the beam comes back. The run 35 is still going.

 

plunger run # 257

Beam dump .... enA (given by operators) * 7 (following entry ID#39) = ... enA

Collimator  ....   enA

Run Data = /onlineNEDA_00/xData/hil099/run_0035_03-03-2023_00h04m26s/needleRU_i35_0035_0059.caendat

RU : 6.18 MB/s

LF : 8.44 MB/s

Supposed Distance = 10 um

position of the target = 10.2 um

micrometer = 8.8 um

Voltage = 7.94 V

 

  142   Tue Mar 7 17:45:18 2023 IPRuns General 

run control = 46

run data = /onlineNEDA_00/xData/hil099/run_0046_07-03-2023_15h08m38s/needleRU_i46_0046_0013.caendat

RU =  6.10 MB/s

LF =   3.26 MB/s

plunger:

plunger run = 422

actual distance =  282.6um

supposed distance = 282.7 um

micrometer =   284.9 um

position =  49.9 um

voltage =  2.968 V

Beam dump =  0.7 nA

Collimater=  0.5 nA

  143   Tue Mar 7 19:24:25 2023 IPRuns General 

run control = 46

run data = /onlineNEDA_00/xData/hil099/run_0046_07-03-2023_15h08m38s/needleRU_i46_0046_0022.caendat

RU =  6.22 MB/s

LF =   3.34 MB/s

plunger:

plunger run = 439

actual distance =  282.5um

supposed distance = 282.7 um

micrometer =   284.9 um

position =  49.8 um

voltage =  2.97 V

Beam dump =  0.7 nA

Collimater=  0.5 nA

  144   Tue Mar 7 20:42:03 2023 IPProblems Beambeam unstable

There was a problem with the beam from 20:19 to 20:30.

Now it is fine.

  145   Tue Mar 7 20:45:13 2023 IPRuns General 

run control = 46

run data =/onlineNEDA_00/xData/hil099/run_0046_07-03-2023_15h08m38s/needleRU_i46_0046_0028.caendat

RU =  4.9 MB/s

LF =   3.14 MB/s

plunger:

plunger run = 452

actual distance =  282.4 um

supposed distance = 282.7 um

micrometer =   284.7 um

position =  49.7 um

voltage =  2.971 V

Beam dump =  0.7 nA

Collimater=  0.5 nA

  146   Tue Mar 7 21:55:45 2023 IPRuns General 

run control = 46

run data = /onlineNEDA_00/xData/hil099/run_0046_07-03-2023_15h08m38s/needleRU_i46_0046_0034.caendat

RU =  4.78 MB/s

LF =   3.10 MB/s

plunger:

plunger run = 464

actual distance =  282.8 um

supposed distance = 282.7 um

micrometer =   285.1 um

position =  49.9 um

voltage =  2.965 V

Beam dump =  0.7 nA

Collimater=  0.5 nA

  188   Thu Mar 9 16:25:57 2023 IPRuns Generalrun 50 stopped

run 50 - stopped

  •  
  • Run number: 50
  • Start time: Thu Mar 9 00:50:57 2023
  • Stop time: Thu Mar 9 16:22:37 2023
  191   Thu Mar 9 19:58:02 2023 IPRuns General 

run control = 51

run data = /onlineNEDA_00/xData/hil099/run_0051_09-03-2023_16h25m16s/needleRU_i51_0051_0018.caendat

RU =  5.93 MB/s

LF =   3.44 MB/s

 

plunger:

plunger run = 927

actual distance =  533.3 um

supposed distance = 532.7 um

micrometer =   533.0 um

position =  300.0 um

voltage =  1.656 V

 

Beam dump: 1 nA

Colimator :  0.6 enA

  192   Thu Mar 9 21:20:06 2023 IPRuns General 

run control = 51

run data = /onlineNEDA_00/xData/hil099/run_0051_09-03-2023_16h25m16s/needleRU_i51_0051_0026.caendat

RU =  6.23MB/s

LF =   3.56 MB/s

 

plunger:

plunger run = 940

actual distance =  532.2 um

supposed distance = 532.7 um

micrometer =   533.0 um

position =  299.5 um

voltage =  1.659 V

 

Beam dump: 1 nA

Colimator :  0.6 enA

  193   Thu Mar 9 22:32:01 2023 IPRuns General 

run control = 51

run data = /onlineNEDA_00/xData/hil099/run_0051_09-03-2023_16h25m16s/needleRU_i51_0051_0032.caendat

RU =  6.12 MB/s

LF =   3.42 MB/s

 

plunger:

plunger run = 952

actual distance =  533.2 um

supposed distance = 532.7 um

micrometer =   533.7 um

position =  300.5 um

voltage =  1.656 V

 

Beam dump: 1 nA

Colimator :  0.6 enA

  206   Fri Mar 10 16:14:19 2023 IPOther GeneralGe - the rate is higher

From 13:00 the rate of the Ge [the chanel 4] is a bit higher (~2.15 kHz). And also the rate of other detectors.

 

  207   Fri Mar 10 16:17:57 2023 IPRuns Generalrun 52 - stopped

run 52 - stopped

 

  • Run number: 52
  • Start time: Fri Mar 10 01:19:56 2023
  • Stop time: Fri Mar 10 16:16:25 2023
  208   Fri Mar 10 16:23:21 2023 IPRuns General 

run control = 53

 

run data = /onlineNEDA_00/xData/hil099/run_0053_10-03-2023_16h18m36s/needleRU_i53_0053_0000.caendat

RU = 7.12 MB/s

LF =   3.50 MB/s

 

plunger:

plunger run = 1134

actual distance =  434.3 um

supposed distance = 435.0 um

micrometer =   436.2 um

position =  201.6 um

voltage =  1.932 V

 

Beam dump: 1 nA

Colimator :  0.5 nA

  209   Fri Mar 10 17:34:07 2023 IPRuns General 

run control = 53

 

run data = /onlineNEDA_00/xData/hil099/run_0053_10-03-2023_16h18m36s/needleRU_i53_0053_0007.caendat

RU = 8.24 MB/s

LF =   4.10 MB/s

 

plunger:

plunger run = 1146

actual distance =  434.7 um

supposed distance = 435.0 um

micrometer =   436.5 um

position =  202.0 um

voltage =  1.932 V

 

Beam dump: 1 nA

Colimator :  0.5 nA

  210   Fri Mar 10 18:42:02 2023 IPRuns General 

run control = 53

 

run data = /onlineNEDA_00/xData/hil099/run_0053_10-03-2023_16h18m36s/needleRU_i53_0053_0014.caendat

RU = 7.41 MB/s

LF =   3.34 MB/s

 

plunger:

plunger run = 1157

actual distance =  434.4 um

supposed distance = 435.0 um

micrometer =   436.8 um

position =  201.7 um

voltage =  1.931 V

 

Beam dump: 1 nA      (sometimes increase to 1.5 nA)

Colimator :  0.5 nA

  211   Fri Mar 10 19:30:48 2023 IPRuns Beamstop beam

the beam was stopped at 19:27


 

  212   Fri Mar 10 19:32:01 2023 IPRuns Beamstart beam

the beam start: 19:31

  213   Fri Mar 10 19:42:57 2023 IPRuns General 

run control = 53

 

run data =/onlineNEDA_00/xData/hil099/run_0053_10-03-2023_16h18m36s/needleRU_i53_0053_0020.caendat

RU = 6.77 MB/s

LF =   3.64 MB/s

 

plunger:

plunger run = 1167

actual distance =  434.4 um

supposed distance = 435 um

micrometer =   437.2 um

position =  201.0 um

voltage =  1.934 V

 

Beam dump: 1 nA      (sometimes increase to 1.5 nA)

Colimator :  0.5 nA

  214   Fri Mar 10 20:54:20 2023 IPProblems Beamlost the beam

the beam was lost at 20:46. The operator is working to solve the problem.

  215   Fri Mar 10 21:00:15 2023 IPProblem Fixed Beamthe beam comes back

the beam comes back at 20:54

ELOG V3.1.5-fc6679b