DSSD:
CH0: 9.7 uA
CH2: 5.525 uA
CH3: 4.295 uA
rate: 5.6 MB/s
about 11:00 the intensity was increased to 34 enA on the target :) Hakim tuned the beam - the source is stable, HOWEVER it turns out from run 7 that the beam is 58Ni
==> DAQ started at : 23-06-17 at 09h-52m-33s
==> Shell name : ./.user_start.sh
File name : run
Run number : 6
User commentary : 62Ni, 197Au, pos 6, E=220 MeV, I~11 enA
Start time : 2023-06-17 09:52:00.021088
==> End of ./.user_start.sh
=> Add a commentary in the setup file ?
at 11 the intensity changed to 34 enA
==> /data_nuball2/N-SI-137/run_6.setup has been written
==> DAQ stopped at : 23-06-17 at 11h-54m-50s
==> shell name : ./.user_stop_trunkv3.sh
User commentary : at 11 the intensity changed to 34 enA
Start time : 2023-06-17 09:52:28.318892
Stop time : 2023-06-17 11:54:53.007720
Run duration: 2:02:24.688828
DATA saved : 937919184
GROUP saved : 0 (0,00 %)
COUNTER saved : 19087029 (2,03 %)
QDC saved : 676359239 (72,11 %)
CRRC4 saved : 0 (0,00 %)
TRAPEZ saved : 242472916 (25,85 %)
SAMPLER saved : 0 (0,00 %)
QT2T saved : 0 (0,00 %)
SCALER saved : 0 (0,00 %)
ELECTROMETER saved : 0 (0,00 %)
MISSING TAG saved : 0 (0,00 %)
MISSED TAG saved : 0 (0,00 %)
OTHER saved : 0 (0,00 %)
DATA lost : 0 (0,00 %)
==> End of ./.user_stop_trunkv3.sh |