| ID |
Date |
Author |
Type |
Category |
Subject |
Text |
 |
|
21
|
Mon Mar 6 16:28:42 2023 |
Iolanda, pjn | Other | General | PARIS BIAS Voltages | |
    |
|
22
|
Mon Mar 6 17:00:29 2023 |
All | | | Calibration with AmBeNi source for PARIS - part 2 | Start 16:44
Start a second calibration run
after changing the voltage offset of the |
|
|
23
|
Mon Mar 6 18:01:02 2023 |
pjn | Other | Other | Target changer problem | Target changet doesn't place taregts
in a correct position.
There is no possibility to put |
|
|
24
|
Mon Mar 6 22:10:30 2023 |
KWL PJN | Other | General | target holder | Target holder - positions:
1 hole
2 quartz |
|
|
25
|
Tue Mar 7 01:16:15 2023 |
Desi, Michalina | | | No target run | Beam intensity is 0.3 enA
No target on the beam, test run
with wheel position 1 |
|
|
26
|
Tue Mar 7 01:56:12 2023 |
Desi, Michalina | | | Run_1 | Run_1
Target position 4 - 208Pb 2 mg/cm^2
START: 01:52 |
|
|
27
|
Tue Mar 7 04:48:22 2023 |
Desi, Michalina | | | Run 2 | We checked if the target is okay before
the start of this run.
On the camera it looked attached and |
 |
|
28
|
Tue Mar 7 05:59:17 2023 |
Desi, Michalina | | | Run 3 | Start 06:00
|
|
|
29
|
Tue Mar 7 08:23:17 2023 |
pjn | Routine | General | run 4 | start 8:20
beam cuurent: 0.3 enA
data stream 4.4 MB/s |
|
|
30
|
Tue Mar 7 09:06:31 2023 |
pjn | Routine | General | run 5 | start 9:05
Energy too high for the digitisers
Gain changed from 6 to |
|
|
31
|
Tue Mar 7 10:19:37 2023 |
pjn | | | Run 3 | for runs 1-3 energy was to high
corrected in run 4
|
|
|
32
|
Tue Mar 7 15:32:02 2023 |
KWL PJN | Other | General | improving beam intensity and a note on the DSSD spectra | Over a night 6/7 of March the beam intensity
was very low , i.e. ~ 0.3 enA (compared to
the 12 enA indicated in the proposal) |
  |
|
33
|
Tue Mar 7 19:24:41 2023 |
Kasia WL, Kasia HK, PJN | | General | run with the empty frame | Hakim et al., played with the beam - they
put the C cone and tested it - it worked
for C but then it didn't work with Ca. |
|
|
34
|
Tue Mar 7 20:15:38 2023 |
pjn | Routine | General | run_6 | Start 20:13
Stop 21:03
Beam current 0.25enA |
|
|
35
|
Tue Mar 7 21:05:10 2023 |
KWL KHK PJN MKOM | Other | General | run 7 - change target to 197Au | we stopped run 6 with 208Pb target and
we change target to the 197Au in order to
see the target excitation in gamma ray spectrum. |
|
|
36
|
Tue Mar 7 22:39:36 2023 |
Kasia WL, Kasia HK, PJN | Other | | comaprison - Au and Pb targets | We decided to change the target to 197Au,
2 mg/cm2 (pos 6) in order to check how the
gamma spectra look like. |
 |
|
37
|
Tue Mar 7 23:35:38 2023 |
PJN MKOM | | | run_8 | ==> DAQ started at : 23-03-08 at 00h-01m-07s
==> Shell name |
|
|
38
|
Wed Mar 8 03:30:36 2023 |
MKOM | | | run_9 | ==> DAQ started at : 23-03-08 at 01h-55m-20s
==> Shell name |
|
|
39
|
Wed Mar 8 05:33:15 2023 |
MKOM | | | run_10 | ==> DAQ started at : 23-03-08 at 04h-08m-42s
==> Shell name |
|
|
40
|
Wed Mar 8 07:44:09 2023 |
MKOM | | | run_11 | ==> DAQ started at : 23-03-08 at 05h-59m-45s
==> Shell name
: ./.user_start.sh |
|