EAGLE IRRADIATIONS EXTERNAL Analysis Students Workshop Shift Plans
GAMMA-ONLY NEEDLE NEEDI COULEX PLUNGER GENERAL
HIL102-128Cs HIL087-176Pt Nd148_2 176Pt HIL109-172Os HIL124-128Cs HIL061 Nd148 HIL106-119Cs HIL097-118Xe HIL099-134Sm April16 xdaq
  HIL099-134Sm  ELOG logo
Message ID: 91     Entry time: Sun Mar 5 22:32:56 2023
Author: MP 
Type: Other 
test:  
Category:  
Subject: change of the target 

See pictures in the attachment:

1) stopper seen from the back (upstream view)

2) stopper  seen from the front (downstream view)

Mind the two small off-center dots. It is clear that the beam hits the edge of the frame.  This is possible because the 5 mm collimator has two small dots outside the 5 mm hole (the collimator  can be seen in the beam tube).

3) old target, upstream view

4)  new target, upstream view, after the stopper drove into it

5) new target, before it was mounted

6) the stopper, after the collision with the target. One of the visible rings is probably due to this collision, other traces probably reflect its complicated history earlier.

 

 

Attachment 1: stopper_seen_upstream.jpg  44 kB  | Show | Hide all | Show all
Attachment 2: stopper_seen_downstream.jpg  187 kB  | Hide | Hide all | Show all
stopper_seen_downstream.jpg
Attachment 3: target_upstream_view.jpg  141 kB  | Hide | Hide all | Show all
target_upstream_view.jpg
Attachment 4: target_new_ustream.jpg  171 kB  | Hide | Hide all | Show all
target_new_ustream.jpg
Attachment 5: target_new_on_table.jpg  375 kB  | Show | Hide all | Show all
Attachment 6: stopper.jpg  178 kB  Uploaded Mon Mar 6 11:24:51 2023  | Hide | Hide all | Show all
stopper.jpg