Fri Mar 10 21:24:29 2023, IP, Runs, , Beam, the beam stopped
|
the beam is stopped at 21:23. |
Fri Mar 10 21:30:42 2023, IP, Problem Fixed, , Beam, the beam is focused
|
the beam is now good focused |
Fri Mar 10 21:00:15 2023, IP, Problem Fixed, , Beam, the beam comes back
|
the beam comes back at 20:54 |
Thu Mar 16 12:13:11 2023, MP, Other, , , test of radioactivity  
|
16/03/2023
Plunger chamber closed, some dummy target and stopper probably inside
run 72 eagle closed
run 73 right half of EAGLE completely opened
Three screenshots are attached:
Run 72 EAGLE closed
1) Three rings. There is significantly more 511 in ring 143 than in 117, 101
2) 5 detectors of ring 143. They all look similar to each other.
Run 73 right half of EAGLE opened
3) 5 detectors of ring 143. The 3 detectors in the opened half hardly see 511 keV, the other 2 do.
Check with Colibri and a gamma scintillator probe ws done: largest activity is visible close to the target chamber, in the region starting at the edge of the chamber, end ending about 6 cm upstream.
About 80 gamma counts/s are seen there. The count rate decreases further upstream.
Background rate: 20 to 30 counts/s, 25 counts/s in Sala Fizykow.
Radioactivity line seen in the spectra, with the same behaviour as 511: 743.5, 936 keV, 1434 keV. These are lines from 52Cr, fed by beta+ decay of 52Mn.
Confirmed by Michain gamma-gamma.
52Mn can be produced in the a2pn channel in the reaction 32S+27Al
|
Mon Feb 27 12:10:24 2023, BS, Other, , Target, target
|
Support of Target = 1.5 mg/cm2 Ta
Target = 1.0 mg/cm2 Cd-106
Stopper = 10 mg/cm2 Au
Beam Dump = ~60 mg/cm2 Au |
Fri Mar 10 19:30:48 2023, IP, Runs, , Beam, stop beam
|
the beam was stopped at 19:27
|
Fri Mar 10 19:32:01 2023, IP, Runs, , Beam, start beam
|
the beam start: 19:31 |
Sat Mar 4 15:02:54 2023, mgb, Runs, , General, running stable
|
RUN CONTROL = 36
Run Data = /onlineNEDA_00/xData/hil099/run_0036_03-03-2023_16h47m35s/needleRU_i36_0036_0122.caendat
RU = 5.99
LF = 3.35
Plunger ;
Planger run = 504
Supposed Dist=10
Micrometer = 11.1
Position = 10.2
Voltage = 8.964
Beam dumb = 1 nA
Collimeter =0.7 nA |
Sun Mar 12 20:55:08 2023, MP, Runs, , , runc62 152 for efficiency calibration
|
started
source in the target position, as precisely as possible
|
Sun Mar 12 20:31:45 2023, GJ, Runs, , General, run_61 - target and stopper and beam dump dismounted.
|
target and stopper and beam dump dismounted.
only the constructional elements of the plunger remained.
pure background, g trigger only.
Michal says the"bg" spectrum did not change... |
Sun Mar 12 03:23:05 2023, AF, Runs, , General, run_0057
|
run control = 57
run data =/onlineNEDA_00/xData/hil099/run_0057_12-03-2023_03h10m10s/
RU = 8.1 MB/s
LF = 3.8 MB/s
plunger:
plunger run = 1484
actual distance = 262.7 um
micrometer = 266.9 um
position = 30 um
voltage = 3.306 V
Beam dump: 0.75 nA
Colimator : 1.1 enA
stop: |
Sat Mar 11 23:30:47 2023, AF, Runs, , General, run_0056
|
run control = 56
run data =/onlineNEDA_00/xData/hil099/run_0056_11-03-2023_23h26m10s
RU = 7.3 MB/s
LF = 3.5 MB/s
plunger:
plunger run = 1445
actual distance = 262.7 um
micrometer = 266.2 um
position = 30 um
voltage = 3.05 V
Beam dump: 0.75 nA
Colimator : 1.1 enA
stop: |
Sat Mar 11 22:52:48 2023, BS, Runs, , General, run_0055
|
run control = 55
run data = /onlineNEDA_00/xData/hil099/run_0055_11-03-2023_00h33m38s/needleRU_i55_0055_0137.caendat
RU = 4.17 MB/s
LF = 3.11 MB/s
plunger:
plunger run = 1439
actual distance = 515 um
micrometer = 578.2 um
position = 282.3 um
voltage = 1.372 V
Beam dump: 0.75 nA
Colimator : 1.1 enA
stop: 11.15 pm -> new plunger distance
|
Tue Mar 7 09:18:01 2023, OST, Problems, , Beam, run number 44 crashed and local filter turned red-but data saved
|
9:08 local filter turned red. Both .caendat and LF .adf files still incrementing. Stopped run 44, started run 45, looks OK.
|
Mon Mar 13 12:16:31 2023, MP, Other, , , run 66
|
run 66 started, radiocativity (background)
|
Sun Mar 12 21:33:54 2023, GJ, Runs, , General, run 63 - 152 Eu during LN2 filling
|
|
Sun Mar 12 19:20:37 2023, MP, Runs, , General, run 60, radioactivity,
|
Run 59 collected data using gg trigger radioactivty
Run 60 trigger changed fropm gg to single g.
Just in the beginning a few minutes gg data could have been collected. |
Sat Mar 11 00:05:06 2023, IP, Runs, , General, run 54 - stopped
|
run 54 - stopped due to change the distance in plunger
- Run number: 54
- Start time: Fri Mar 10 23:14:54 2023
- Stop time: Sat Mar 11 00:02:37 2023
|
Fri Mar 10 23:27:51 2023, IP, Problems, , Software, run 53 - stopped
|
the daq crashed at 22:43 -- problem with Local Filter
the run 53 - stopped |
Fri Mar 10 16:17:57 2023, IP, Runs, , General, run 52 - stopped
|
run 52 - stopped
- Run number: 52
- Start time: Fri Mar 10 01:19:56 2023
- Stop time: Fri Mar 10 16:16:25 2023
|
|