  159   Wed Mar 8 10:27:26 2023 IK, BSOther GeneralGe spectra

Count rates are still a bit high (~2.6kHz for EAGLE det4). Ge spectra looks fine compared to earlier ones.


 

Attachment 1: Screenshot_2023-03-08_10-24-20.png
Screenshot_2023-03-08_10-24-20.png
  166   Wed Mar 8 15:57:53 2023 IK, AMProblems GeneralBeam issue

no beam in 15:52 - 16:21 due to power supply problem

  60   Fri Mar 3 16:47:29 2023 IKRuns GeneralRun 36 started

Run 36 Started

New Beam energy is 150 MeV

The beam dumb currennt is 2.5 enA.

Plunger run = 282

 

  61   Fri Mar 3 17:52:41 2023 IKProblem Fixed HardwareBeamdump readout issue - solved

Current readout issues from beamdump. Beam stopped from 17:46-17:52, run 36 ongoing.

MP & GJ checking the grounding and connection the beamdump readout. No visible issue found in the exp hall, but copper grounding wire was tightened, which seemingly resolved the issue (stability of beamdump readout).   

  62   Fri Mar 3 19:41:27 2023 IKProblems HardwareBeamdump readout issue Vol.2.

Issue described in #61 continues to persist.

Beam stopped from 19:20 to 19:32, run 36 ongoing; MP, GJ, BS entering the experimental hall. 

They changed the position of the grounding point on the chamber, moving it downstream after a fitting/joining part (A to B on the attached picture [artist: GJ]).

 

Attachment 1: 333626140_152534624340296_7230383118242592907_n.jpg
333626140_152534624340296_7230383118242592907_n.jpg
  115   Mon Mar 6 19:08:51 2023 IKRuns General 

RUN CONTROL = 42

Data =/onlineNEDA_00/xData/hil099/run_0042_06-03-2023_09h54m24s/needleRU_i42_0042_0045.caendat

RU = 6.95 MB/s

LF = 3.61 MB/s

Plunger ;

Plunger run = 196

Supposed Dist= 242.7 um

Micrometer = 245.2 um

Position = 9.7  um

Actual distance = 245.2 um

Voltage = 3.821 V

Beam dump = 1enA

 

  116   Mon Mar 6 20:29:45 2023 IKRuns General 

RUN CONTROL = 42

Data =/onlineNEDA_00/xData/hil099/run_0042_06-03-2023_09h54m24s/needleRU_i42_0042_0053.caendat

RU = 6.75 MB/s

LF = 3.54 MB/s

Plunger ;

Plunger run = 210

Supposed Dist= 242.7 um

Micrometer = 245.2 um

Position = 9.6  um

Actual distance = 242.3 um

Voltage = 4.184 V

  117   Mon Mar 6 22:30:46 2023 IKRuns General 

RUN CONTROL = 42

Data =/onlineNEDA_00/xData/hil099/run_0042_06-03-2023_09h54m24s/needleRU_i42_0042_0065.caendat

RU = 6.64 MB/s

LF = 3.54 MB/s

Plunger ;

Plunger run = 230

Supposed Dist= 242.7 um

Micrometer = 246 um

Position = 9.7  um

Actual distance = 243.1 um

Voltage = 4.184 V

Beam dump = 1enA

  157   Wed Mar 8 07:57:05 2023 IKProblems Beambeam unstable

The beam was unstable from 7:55. Stabilized around 8:03.

Counting rates are higher, EAGLE det4 went to ~2.5kHZ from ~2kHz (attached).

According to the operator, a bit of a tuning was done, current is 1nA.

 

run control = 48

run data =  /onlineNEDA_00/xData/hil099/run_0048_08-03-2023_01h08m57s/needleRU_i48_0048_0041.caendat

RU =  10.4 MB/s

LF =   4.3 MB/s

 

 

 

 

Attachment 1: Screenshot_2023-03-08_08-17-41.png
Screenshot_2023-03-08_08-17-41.png
  158   Wed Mar 8 09:31:43 2023 IKRuns GeneralRun 48 stopped, run 49 started

Run 48 stopped at 9:29 to start a new run.

Run 49 is started okay at 9:31.

 

run control = 49

run data = /onlineNEDA_00/xData/hil099/run_0048_08-03-2023_01h08m57s/needleRU_i48_0048_0041.caendat

RU =  10.1 MB/s

LF =   4.68MB/s

plunger:

plunger run = 582

actual distance =  383.1 um

supposed distance = 382.7 um

micrometer =   385.8 um

position =  150.5 um

voltage =  2.145 V

 

Beam dump 0.7 nA

 

 

 

 

 

 

  160   Wed Mar 8 10:31:10 2023 IKRuns GeneralRun 49

run control = 49

run data = /onlineNEDA_00/xData/hil099/run_0049_08-03-2023_09h31m08s/needleRU_i49_0049_0008.caendat

RU =  10.6 MB/s

LF =   4.89MB/s

plunger:

plunger run = 591

actual distance =  383.0 um

supposed distance = 382.7 um

micrometer =   385.8 um

position =  150.3 um

voltage =  2.145 V

 

Beam dump 0.7 nA

 

 

 

 

 

 

  161   Wed Mar 8 11:42:14 2023 IKProblems GeneralRun 49

Counting rates continued to increase (det4 > 3kHz). Beam current looked fine on the beam dump, but beam is fluctuating, and can reach 2nA on the collimator.  Asked for improved focusing.

Attached screenshots and Ge spectra from before changing anything.

 

run control = 49

run data = /onlineNEDA_00/xData/hil099/run_0049_08-03-2023_09h31m08s/needleRU_i49_0049_0020.caendat

RU =  13.3 MB/s

LF =   6.15MB/s

plunger:

plunger run = 603

actual distance =  382.7 um

supposed distance = 382.7 um

micrometer =   385.9 um

position =  150.0 um

voltage =  2.146 V

 

Beam dump 0.7 nA

Collimator ~1.5-2nA when the generator retunes itself (prob the beam gets defocused at those moments)

 

 

 

 

 

Attachment 1: Screenshot_2023-03-08_11-38-47.png
Screenshot_2023-03-08_11-38-47.png
Attachment 2: Screenshot_2023-03-08_11-38-19.png
Screenshot_2023-03-08_11-38-19.png
Attachment 3: Screenshot_2023-03-08_11-37-37.png
Screenshot_2023-03-08_11-37-37.png
  162   Wed Mar 8 12:11:59 2023 IKProblem Fixed Generalbeam tuned

Beam tuning was made, focusing significantly improved.

 

Intensity:

beam dump: 0.9-1 nA,

collimator: 0.5 nA.

 

Rates:

RU =  8.2 MB/s

LF =   4.03 MB/s

EAGLE det4: 2.2 kHz

 

  163   Wed Mar 8 13:02:38 2023 IKRuns GeneralRun 49

run control = 49

run data = /onlineNEDA_00/xData/hil099/run_0049_08-03-2023_09h31m08s/needleRU_i49_0049_0030.caendat

RU =  7.86 MB/s

LF =   3.87 MB/s

plunger:

plunger run = 616

actual distance =  382.7 um

supposed distance = 382.7 um

micrometer =   385.7 um

position =  150.0 um

voltage =  2.147 V

 

Beam dump 0.7 nA

 

 

 

 

 

 

  164   Wed Mar 8 13:04:05 2023 IKRuns GeneralGe spectra

Ge spectra after #161 - #162 beam tuning.

Attachment 1: Screenshot_2023-03-08_13-03-10.png
Screenshot_2023-03-08_13-03-10.png
  245   Sun Mar 12 03:05:45 2023 GJ, AFProblems Networkno data flux visible in grafena, LF prints "write: Broken pipe"
As in the title, see below.
The data are still being constantly written on the disks with usual rate (also visible on grafena).
Greware is also seeing data.

beeper output:
no new data about the growth for 37 s !!!
Noticed at Sun Mar 12 02:50:42 2023
and weirdo scream followed.


LF output:

write: Broken pipe
  0-LF_neda_2:        98 ev ( 107153)*30   Tot=26234475   2253/s
write: Broken pipe
  0-LF_eagle_1:      881 ev ( 120281)*31   Tot=295856141  24268/s
write: Broken pipe
write: Broken pipe
  0-LF_neda_3:         3 ev (   3909)*5980 Tot=375647125  30917/s
write: Broken pipe
  0-LF_neda_1:        92 ev (  92962)*40   Tot=32523205   2820/s
write: Broken pipe
write: Broken pipe
  0-LF_neda_0:       104 ev ( 117997)*33   Tot=38078515   3323/s
  0-LF_eagle_0:      720 ev (  63994)*31   Tot=268339966  22243/s
write: Broken pipe
write: Broken pipe
write: Broken pipe
write: Broken pipe
write: Broken pipe
write: Broken pipe
  0-LF_neda_2:        72 ev (  87376)*31   Tot=26236761   2274/s
write: Broken pipe
  0-LF_eagle_1:      714 ev ( 104681)*35   Tot=295880265  23988/s
write: Broken pipe
write: Broken pipe
  0-LF_neda_3:         9 ev (   3988)*5870 Tot=375677518  30545/s
write: Broken pipe
  0-LF_neda_1:        93 ev (  98610)*34   Tot=32525919   2698/s
  1   Sun Feb 26 16:50:56 2023 GJOther Generalproposal
Attachment 1: HIL-Proposal-134Sm-Bahadir-Saygi-very-last.pdf
HIL-Proposal-134Sm-Bahadir-Saygi-very-last.pdf HIL-Proposal-134Sm-Bahadir-Saygi-very-last.pdf HIL-Proposal-134Sm-Bahadir-Saygi-very-last.pdf HIL-Proposal-134Sm-Bahadir-Saygi-very-last.pdf HIL-Proposal-134Sm-Bahadir-Saygi-very-last.pdf HIL-Proposal-134Sm-Bahadir-Saygi-very-last.pdf HIL-Proposal-134Sm-Bahadir-Saygi-very-last.pdf
  2   Sun Feb 26 17:26:45 2023 GJOther GeneralList of participants

To be filled in, with affiliation and email.

Presumably, for later publication purposes.
 

Alphabetically by family name, please.

Budak, Mustafa Guray - Gazi University, mbudak@gazi.edu.tr

Ciemała, Michał - IFJ PAN, Kraków, Poland - Michal.Ciemala@ifj.edu.pl

Deary, James, - University of West of Scotland - james.deary@uws.ac.uk

Fijałkowska, Aleksandra,  aleksandra.fijalkowska@fuw.edu.pl

Fransen' Christoph IKP JOELN  fransen@ikp.uni-koeln.de

Goasduff, Alain - INFN-LNL alain.goasduff@lnl.infn.it

Grębosz, Jurek - IFJ PAN, Kraków, Poland

Jaworski, Grzegorz - HIL UW, Poland - tatrofil@slcj.uw.edu.pl

O'Donnell, David - University of West of Scotland - david.odonnell@uws.ac.uk

Palacz, Marcin - HIL UW, Poland - palacz@slcj.uw.edu.pl

Piętka, Iwona - Faculty of Physics, UW - iz.pietka@student.uw.edu.pl

Poklepa, Wiktor - UW, Poland, w.poklepa@student.uw.edu.pl

Saygi, Bahadir - Ankara University, Turkey - bahadir.saygi@ankara.edu.tr

Solak, Krzysztof - UW Poland, krzysztof.solak@post.pl

Szlęzak, Klara - UW, Poland, k.szlezak@student.uw.edu.pl

Temiz, Omer Sefa - Ankara University, Turkey - omer.temiz.95@gmail.com

White, Dylan, - University of West of Scotland - dylan.white@uws.ac.uk

 

 

 

 

  3   Mon Feb 27 02:49:10 2023 GJRuns Generalcalibs - 2x 152Eu - run 0
Run number: 0
Trigger: g
Start time: Mon Feb 27 02:43:50 2023
Stop time: Mon Feb 27 03:21:01 2023

Two Eu sources hanging in more or less focus points of two partially open halves of EAGLE.
  39   Thu Mar 2 23:04:01 2023 GJProblem Fixed HardwareConnection of the plunger cables, grounding, beam read-out for the operators
Notes of the measurements with different conditions are attached.

Conclusion:
What is read out by the operators on the blue cable should be multiplied by 7 to get a real value in enA.
Attachment 1: Slp823030222550.pdf
Slp823030222550.pdf
ELOG V3.1.5-fc6679b