EAGLE IRRADIATIONS EXTERNAL Analysis Students Workshop Shift Plans
GAMMA-ONLY NEEDLE NEEDI COULEX PLUNGER GENERAL
HIL102-128Cs HIL087-176Pt Nd148_2 176Pt HIL109-172Os HIL124-128Cs HIL061 Nd148 HIL106-119Cs HIL097-118Xe HIL099-134Sm April16 xdaq
  HIL099-134Sm, Page 11 of 14  ELOG logo
New entries since:Thu Jan 1 01:00:00 1970
ID Datedown Author Type test Category Subject Text Attachments
  64   Fri Mar 3 23:38:28 2023 SPRuns GeneralHow different Ge countAll germanium detecors look reasonable,
as attached.
 ge_en_cal_230303_2337.png 
  63   Fri Mar 3 20:50:31 2023 IK, MP, GJOther Data analysisGe spectraGe rates increasing, similar to what it
was 24h before. Asking to decrease beam intensity
by a factor of 2.
 ge_rings101_117_143_Screenshot_2023-03-03_20-44-07.pngGe_rates_too_high.png 
  62   Fri Mar 3 19:41:27 2023 IKProblems HardwareBeamdump readout issue Vol.2.Issue described in #61 continues to
persist.

Beam stopped from 19:20 to 19:32,
 333626140_152534624340296_7230383118242592907_n.jpg 
  61   Fri Mar 3 17:52:41 2023 IKProblem Fixed HardwareBeamdump readout issue - solvedCurrent readout issues from beamdump. Beam
stopped from 17:46-17:52, run 36 ongoing.

MP & GJ checking the grounding
  
  60   Fri Mar 3 16:47:29 2023 IKRuns GeneralRun 36 startedRun 36 Started

New Beam energy is 150 MeV

The beam dumb currennt is 2.5 enA.
  
  59   Fri Mar 3 15:04:33 2023 KWLOther Generalrun 35 stopped Run 35 stopped. An attempt to check if
we can get 5 MeV  higher beam energy.
  
  58   Fri Mar 3 14:22:12 2023 IPRuns General the beam comes back. The run 35 is still
going.

 
  
  57   Fri Mar 3 13:54:41 2023 IP. KWLRuns Generalbeam energy measurementbeam stop due to the beam energy measurement

The beam energy: ~145 MeV
  
  56   Fri Mar 3 13:43:56 2023 IP. KWLRuns  511 annihilation and 279 Au lines in Ge ringsThe counting rate in 511 keV line for sum
of the Ge detectors placed at 101, 117 and
143 degrees (with approved ACS). The largest
 ge_rings101_117_143_acceptedACS_gold_line_279keV.pngge_rings101_117_143_acceptedACS.png 
  55   Fri Mar 3 12:11:24 2023 IPRuns General the beam comes back.   
  54   Fri Mar 3 11:48:29 2023 IPRuns Generalbeam stoppedThe beam is gone.   
  53   Fri Mar 3 11:37:25 2023 IPRuns General plunger run # 230

Beam dump 1.2  enA (given
by operators) * 7 (following entry ID#39)
  
  52   Fri Mar 3 10:21:18 2023 IP. KWLRuns Generalbeam intensity back to 1.25 enA at the beam dumpwe increased beam intensity to 1.25 enA
(readout at the beam dump)
  
  51   Fri Mar 3 10:09:20 2023 IP. KWLRuns Generalbeam intensity decreased to 0.3 enA (at beam dump) on our request // we noticed yesterday that GE at 143
degrees counts more than those placed at
117 and 101. The 511 keV line (+ background)
 Ge_beamInten_03enA_differentYscale.pngGe_beamInten_03enA_sameYscale.png 
  50   Fri Mar 3 09:30:15 2023 IP. KWLRuns General plunger run # 208

Beam dump 0.75 enA (given by operators)
* 7 (following entry ID#39) = 5.25 enA
  
  49   Fri Mar 3 08:20:13 2023 KWLRuns General plunger run # 196

Beam dump 1 enA (given by operators)
* 7 (following entry ID#39) = 7 enA
  
  48   Fri Mar 3 07:32:28 2023 OSTRuns General plunger run # 188

Beam dump 2.5 enA

Collimator  0.8 enA
  
  47   Fri Mar 3 06:24:03 2023 OSTRuns General plunger run # 178

Beam dump 2.5 enA

Collimator  0.9 enA
  
  46   Fri Mar 3 05:18:35 2023 OSTRuns General plunger run # 167

 

Beam dump 2.5 enA
  
  45   Fri Mar 3 04:15:32 2023 mgbRuns General plunger run # 157

 

Beam dump 2.5 enA
  
ELOG V3.1.5-fc6679b