EAGLE IRRADIATIONS EXTERNAL Analysis Students Workshop Shift Plans
GAMMA-ONLY NEEDLE NEEDI COULEX PLUNGER GENERAL
HIL102-128Cs HIL087-176Pt Nd148_2 176Pt HIL109-172Os HIL124-128Cs HIL061 Nd148 HIL106-119Cs HIL097-118Xe HIL099-134Sm April16 xdaq
  HIL099-134Sm, Page 3 of 14  ELOG logo
Entry  Fri Mar 3 00:09:19 2023, MP, AT, Runs, , , run 35 
Started after beam current was reduced by a factor of 2

plunger run # 116

Earlier:   CUP#6  100 enA
Entry  Fri Mar 3 01:15:27 2023, mgb, Runs, , General,  
 

plunger run # 126

Earlier:   CUP#6  100 enA
Entry  Fri Mar 3 02:20:46 2023, mgb, Runs, , General,  
plunger run # 137

 

Beam dump 2.5 enA
Entry  Fri Mar 3 02:23:45 2023, GJ, Problems, , Software, builder gate, TS offsets run_0035_BU_lenghts.png
Data from current run - 35, with limited beam current and rates - see a recent post by Güray.
BU level, so what we see in Greware (both online & nearline).
Attached is the fold of Germaniums.
Entry  Fri Mar 3 03:19:34 2023, mgb, Runs, , General,  
plunger run # 147

 

Beam dump 2.5 enA
Entry  Fri Mar 3 04:15:32 2023, mgb, Runs, , General,  
plunger run # 157

 

Beam dump 2.5 enA
Entry  Fri Mar 3 05:18:35 2023, OST, Runs, , General,  
plunger run # 167

 

Beam dump 2.5 enA
Entry  Fri Mar 3 06:24:03 2023, OST, Runs, , General,  
plunger run # 178

Beam dump 2.5 enA

Collimator  0.9 enA
Entry  Fri Mar 3 07:32:28 2023, OST, Runs, , General,  
plunger run # 188

Beam dump 2.5 enA

Collimator  0.8 enA
Entry  Fri Mar 3 08:20:13 2023, KWL, Runs, , General,  
plunger run # 196

Beam dump 1 enA (given by operators) * 7 (following entry ID#39) = 7 enA

Collimator   0.75  enA
Entry  Fri Mar 3 09:30:15 2023, IP. KWL, Runs, , General,  
plunger run # 208

Beam dump 0.75 enA (given by operators) * 7 (following entry ID#39) = 5.25 enA

Collimator   0.75  enA
Entry  Fri Mar 3 10:09:20 2023, IP. KWL, Runs, , General, beam intensity decreased to 0.3 enA (at beam dump) on our request  Ge_beamInten_03enA_differentYscale.pngGe_beamInten_03enA_sameYscale.png
// we noticed yesterday that GE at 143 degrees counts more than those placed at 117 and 101. The 511 keV line (+ background) is much more pronounced
for Ge at 143 degrees. To investigate this issue we decreased the beam intensity to 0.3 enA ( value given by operators at the beam dump ). 

Conclusion - decrease of the beam intensity does not explain above observations (se attached figs)
Entry  Fri Mar 3 10:21:18 2023, IP. KWL, Runs, , General, beam intensity back to 1.25 enA at the beam dump 
we increased beam intensity to 1.25 enA (readout at the beam dump)
Entry  Fri Mar 3 11:37:25 2023, IP, Runs, , General,  
plunger run # 230

Beam dump 1.2  enA (given by operators) * 7 (following entry ID#39) = 8.4 enA

Collimator   0.6  enA
Entry  Fri Mar 3 11:48:29 2023, IP, Runs, , General, beam stopped 
The beam is gone.
Entry  Fri Mar 3 12:11:24 2023, IP, Runs, , General,  
the beam comes back.
Entry  Fri Mar 3 13:43:56 2023, IP. KWL, Runs, , , 511 annihilation and 279 Au lines in Ge rings ge_rings101_117_143_acceptedACS_gold_line_279keV.pngge_rings101_117_143_acceptedACS.png
The counting rate in 511 keV line for sum of the Ge detectors placed at 101, 117 and 143 degrees (with approved ACS). The largest intensity is visible
for Ge at 143 degrees, lowest for 101 deg.

=============================== RING 101
Entry  Fri Mar 3 13:54:41 2023, IP. KWL, Runs, , General, beam energy measurement 
beam stop due to the beam energy measurement

The beam energy: ~145 MeV
Entry  Fri Mar 3 14:22:12 2023, IP, Runs, , General,  
the beam comes back. The run 35 is still going.

 

plunger run # 257
Entry  Fri Mar 3 15:04:33 2023, KWL, Other, , General, run 35 stopped  
Run 35 stopped. An attempt to check if we can get 5 MeV  higher beam energy.
ELOG V3.1.5-fc6679b