| ID |
Date |
Author |
Type |
test |
Category |
Subject |
|
165
|
Wed Mar 8 14:47:34 2023 |
AM | Runs | | Beam | beam unstable |
two drops in beam intesitivity at 14:33, 14:37 and 14:51 |
|
164
|
Wed Mar 8 13:04:05 2023 |
IK | Runs | | General | Ge spectra |
Ge spectra after #161 - #162 beam tuning. |
| Attachment 1: Screenshot_2023-03-08_13-03-10.png
|
|
|
163
|
Wed Mar 8 13:02:38 2023 |
IK | Runs | | General | Run 49 |
run control = 49
run data = /onlineNEDA_00/xData/hil099/run_0049_08-03-2023_09h31m08s/needleRU_i49_0049_0030.caendat
RU = 7.86 MB/s
LF = 3.87 MB/s
plunger:
plunger run = 616
actual distance = 382.7 um
supposed distance = 382.7 um
micrometer = 385.7 um
position = 150.0 um
voltage = 2.147 V
Beam dump 0.7 nA
|
|
162
|
Wed Mar 8 12:11:59 2023 |
IK | Problem Fixed | | General | beam tuned |
Beam tuning was made, focusing significantly improved.
Intensity:
beam dump: 0.9-1 nA,
collimator: 0.5 nA.
Rates:
RU = 8.2 MB/s
LF = 4.03 MB/s
EAGLE det4: 2.2 kHz
|
|
161
|
Wed Mar 8 11:42:14 2023 |
IK | Problems | | General | Run 49 |
Counting rates continued to increase (det4 > 3kHz). Beam current looked fine on the beam dump, but beam is fluctuating, and can reach 2nA on the collimator. Asked for improved focusing.
Attached screenshots and Ge spectra from before changing anything.
run control = 49
run data = /onlineNEDA_00/xData/hil099/run_0049_08-03-2023_09h31m08s/needleRU_i49_0049_0020.caendat
RU = 13.3 MB/s
LF = 6.15MB/s
plunger:
plunger run = 603
actual distance = 382.7 um
supposed distance = 382.7 um
micrometer = 385.9 um
position = 150.0 um
voltage = 2.146 V
Beam dump 0.7 nA
Collimator ~1.5-2nA when the generator retunes itself (prob the beam gets defocused at those moments)
|
| Attachment 1: Screenshot_2023-03-08_11-38-47.png
|
|
| Attachment 2: Screenshot_2023-03-08_11-38-19.png
|
|
| Attachment 3: Screenshot_2023-03-08_11-37-37.png
|
|
|
160
|
Wed Mar 8 10:31:10 2023 |
IK | Runs | | General | Run 49 |
run control = 49
run data = /onlineNEDA_00/xData/hil099/run_0049_08-03-2023_09h31m08s/needleRU_i49_0049_0008.caendat
RU = 10.6 MB/s
LF = 4.89MB/s
plunger:
plunger run = 591
actual distance = 383.0 um
supposed distance = 382.7 um
micrometer = 385.8 um
position = 150.3 um
voltage = 2.145 V
Beam dump 0.7 nA
|
|
159
|
Wed Mar 8 10:27:26 2023 |
IK, BS | Other | | General | Ge spectra |
Count rates are still a bit high (~2.6kHz for EAGLE det4). Ge spectra looks fine compared to earlier ones.
|
| Attachment 1: Screenshot_2023-03-08_10-24-20.png
|
|
|
158
|
Wed Mar 8 09:31:43 2023 |
IK | Runs | | General | Run 48 stopped, run 49 started |
Run 48 stopped at 9:29 to start a new run.
Run 49 is started okay at 9:31.
run control = 49
run data = /onlineNEDA_00/xData/hil099/run_0048_08-03-2023_01h08m57s/needleRU_i48_0048_0041.caendat
RU = 10.1 MB/s
LF = 4.68MB/s
plunger:
plunger run = 582
actual distance = 383.1 um
supposed distance = 382.7 um
micrometer = 385.8 um
position = 150.5 um
voltage = 2.145 V
Beam dump 0.7 nA
|
|
157
|
Wed Mar 8 07:57:05 2023 |
IK | Problems | | Beam | beam unstable |
The beam was unstable from 7:55. Stabilized around 8:03.
Counting rates are higher, EAGLE det4 went to ~2.5kHZ from ~2kHz (attached).
According to the operator, a bit of a tuning was done, current is 1nA.
run control = 48
run data = /onlineNEDA_00/xData/hil099/run_0048_08-03-2023_01h08m57s/needleRU_i48_0048_0041.caendat
RU = 10.4 MB/s
LF = 4.3 MB/s
|
| Attachment 1: Screenshot_2023-03-08_08-17-41.png
|
|
|
156
|
Wed Mar 8 07:30:15 2023 |
KS, KSz | Problems | | Beam | beam unstable |
The beam was unstable from 7:18 to 7:25. |
|
155
|
Wed Mar 8 06:25:53 2023 |
KS, KSz | Runs | | General | |
run control = 48
run data = /onlineNEDA_00/xData/hil099/run_0048_08-03-2023_01h08m57s/needleRU_i48_0048_0029.caendat
RU = 6.59 MB/s
LF = 3.35 MB/s
plunger:
plunger run = 550
actual distance = 382,5 um
supposed distance = 382.7 um
micrometer = 384.6 um
position = 149.8um
voltage = 2.146 V
Beam dump = 1.5 nA
Collimater= 0.7 nA (?) |
|
154
|
Wed Mar 8 04:24:40 2023 |
KS, KSz | Runs | | General | Run 48 |
run control = 48
run data = /onlineNEDA_00/xData/hil099/run_0048_08-03-2023_01h08m57s/needleRU_i48_0048_0017.caendat
RU = 5.75 MB/s
LF = 3.21 MB/s
plunger:
plunger run = 530
actual distance = 382,7 um
supposed distance = 382.7 um
micrometer = 384.3 um
position = 150.3 um
voltage = 2.146 V
Beam dump = 1.5 nA
Collimater= 0.7 nA (?) |
|
153
|
Wed Mar 8 02:45:53 2023 |
KS, KSz | Other | | Beam | increase in Counting Rates |
Since 2:32 increased counting rate observed:
Sinde 3:45 decrease to 1.5 kHz ch4.
run control = 48
/onlineNEDA_00/xData/hil099/run_0048_08-03-2023_01h08m57s/needleRU_i48_0048_0007.caendat
run data =
RU = 8.69 MB/s
LF = 3.79 MB/s
Eagle Rated ch4: around 2.3 kHz
plunger: (2:48)
plunger run = 514
actual distance = 382.7 um
supposed distance = 382.7 um
micrometer = 383.5 um
position = 149.8 um
voltage = 2.144 V
Beam dump = 1.5 nA
Collimater= 0.5 nA |
|
152
|
Wed Mar 8 01:24:58 2023 |
KS, KSz | Runs | | General | New run started 48 (new distance) |
run control = 48
run data = /onlineNEDA_00/xData/hil099/run_0048_08-03-2023_01h08m57s/needleRU_i48_0048_0000.caendat
RU = 5.09 MB/s
LF = 3.15 MB/s
plunger:
plunger run = 498
actual distance = 382.7 um
supposed distance = 382.7 um
micrometer = 383.4 um
position = 149.7 um
voltage = 2.146 V
Beam dump = 0.7 nA
Collimater= 0.5 nA |
|
151
|
Wed Mar 8 01:24:04 2023 |
BS | Runs | | General | Run 47 Stopped to Change Distance Change |
Run 47 stopped and distance changed from 50 um (+ 100 um offset) to 150 um (+ 100 um offset)
Last plunger run for 50 um (+ 100 um offset) is 495 |
|
149
|
Wed Mar 8 00:31:05 2023 |
KS, KSz | Runs | | General | Run 47 standard info |
run control = 47
run data = /onlineNEDA_00/xData/hil099/run_0047_07-03-2023_23h42m03s/needleRU_i47_0047_0003.caendat
RU = 5.12 MB/s
LF = 3.32 MB/s
plunger:
plunger run = 491
actual distance = 282.9 um
supposed distance = 282.7 um
micrometer = 285.12 um
position = 50.2 um
voltage = 2.963 V
Beam dump = 0.7 nA
Collimater= 0.5 nA |
|
148
|
Tue Mar 7 23:54:05 2023 |
IP, KS | Runs | | General | |
run control = 47
run data = /onlineNEDA_00/xData/hil099/run_0047_07-03-2023_23h42m03s/needleRU_i47_0047_0000.caendat
RU = 4.47 MB/s
LF = 3.26 MB/s
plunger:
plunger run = 484
actual distance = 282.8 um
supposed distance = 282.7 um
micrometer = 285.2 um
position = 50.1 um
voltage = 2.965 V
Beam dump = 0.7 nA
Collimater= 0.5 nA |
|
147
|
Tue Mar 7 23:39:52 2023 |
IP, KS | Runs | | General | run 46 stopped |
Run 46 - stopped
- Run number: 46
- Start time: Tue Mar 7 15:09:06 2023
- Stop time: Tue Mar 7 23:38:07 2023
|
|
146
|
Tue Mar 7 21:55:45 2023 |
IP | Runs | | General | |
run control = 46
run data = /onlineNEDA_00/xData/hil099/run_0046_07-03-2023_15h08m38s/needleRU_i46_0046_0034.caendat
RU = 4.78 MB/s
LF = 3.10 MB/s
plunger:
plunger run = 464
actual distance = 282.8 um
supposed distance = 282.7 um
micrometer = 285.1 um
position = 49.9 um
voltage = 2.965 V
Beam dump = 0.7 nA
Collimater= 0.5 nA |
|
145
|
Tue Mar 7 20:45:13 2023 |
IP | Runs | | General | |
run control = 46
run data =/onlineNEDA_00/xData/hil099/run_0046_07-03-2023_15h08m38s/needleRU_i46_0046_0028.caendat
RU = 4.9 MB/s
LF = 3.14 MB/s
plunger:
plunger run = 452
actual distance = 282.4 um
supposed distance = 282.7 um
micrometer = 284.7 um
position = 49.7 um
voltage = 2.971 V
Beam dump = 0.7 nA
Collimater= 0.5 nA |