EAGLE IRRADIATIONS EXTERNAL Analysis Students Workshop Shift Plans
GAMMA-ONLY NEEDLE NEEDI COULEX PLUNGER GENERAL
HIL102-128Cs HIL087-176Pt Nd148_2 176Pt HIL109-172Os HIL124-128Cs HIL061 Nd148 HIL106-119Cs HIL097-118Xe HIL099-134Sm April16 xdaq
  HIL099-134Sm, Page 8 of 14  ELOG logo
New entries since:Thu Jan 1 01:00:00 1970
ID Date Author Type test Category Subjectdown Text Attachments
  107   Mon Mar 6 09:53:06 2023 OSTProblems BeamBeam dump decreased 2.5 nA to 1.5 nA- stopped run 419:20 to 9:50 am beam current stayed 2.5
nA . After 9:50 am decrease 1.5 nA
  
  89   Sun Mar 5 15:07:24 2023 mgbRuns GeneralBeam dump decreased 1.0 nA to 0.75RUN CONTROL = 37

Data = /onlineNEDA_00/xData/hil099/run_0037_04-03-2023_22h56m17s/needleRU_i37_0037_0106.caendat

RU = 8.65 MB/s
  
  250   Sun Mar 12 09:15:00 2023 EGOther  Array_monitors mat refresh synchronizationBeam stable, counting rate within limits,
plunger distance within the given tollerance,
gamma spectra ok, everything looks good but....
  
  56   Fri Mar 3 13:43:56 2023 IP. KWLRuns  511 annihilation and 279 Au lines in Ge ringsThe counting rate in 511 keV line for sum
of the Ge detectors placed at 101, 117 and
143 degrees (with approved ACS). The largest
 ge_rings101_117_143_acceptedACS_gold_line_279keV.pngge_rings101_117_143_acceptedACS.png 
  265   Tue Jan 23 16:55:21 2024 yesOther  106Cd certificate   Slp823030223120.pdf 
  15   Wed Mar 1 20:10:38 2023 BS, DODOther General Run 26 is going on but not much for the
moment in terms of any useful data.

And half of the EAGLE is opened.
  
  16   Wed Mar 1 21:59:45 2023 MB BSOther General Offset of the plunger is 60 um.

new distcal01_vac_after_opening
  
  17   Thu Mar 2 00:30:29 2023 BS, DODRuns General Run 27 with single gamma trigger

Plunger feedback system is not
conected.
  
  18   Thu Mar 2 04:17:40 2023 DODRuns General Run 27 with single gamma trigger

Plunger feedback system is not
conected.
  
  19   Thu Mar 2 05:33:34 2023 ost-dodRuns General Run 27 with single gamma trigger

Plunger feedback system is not
conected.
  
  20   Thu Mar 2 07:40:55 2023 ost-dodRuns General Run 27 with single gamma trigger

Plunger feedback system is not
conected.
  
  23   Thu Mar 2 09:24:47 2023 ost-mgbRunsRun 27 stoppedGeneral Run 27 stopped   
  26   Thu Mar 2 11:14:44 2023 ost-mgbRuns General un 29 with single gamma trigger

Plunger feedback system is not
connected.
  
  29   Thu Mar 2 12:09:44 2023 ost-mgbRuns General beam stop,   
  31   Thu Mar 2 14:59:32 2023 mgbRuns General  

 

Data
  
  33   Thu Mar 2 16:06:17 2023 A.T.Runs General Data

Position = 522.6

Supposed = 520
  
  41   Fri Mar 3 01:15:27 2023 mgbRuns General  

plunger run # 126

Earlier:   CUP#6 
  
  42   Fri Mar 3 02:20:46 2023 mgbRuns General plunger run # 137

 

Beam dump 2.5 enA
  
  44   Fri Mar 3 03:19:34 2023 mgbRuns General plunger run # 147

 

Beam dump 2.5 enA
  
  45   Fri Mar 3 04:15:32 2023 mgbRuns General plunger run # 157

 

Beam dump 2.5 enA
  
ELOG V3.1.5-fc6679b