Tue Mar 7 15:14:29 2023, OST, Problem Fixed, , Software, Run 46 started-15_Ge and number 5 anticompton working now.
|
VME crate with CAEN digitizers was rebooted.
Run 46 started, number 15_Ge and number 5 anticompton dedector working now.
|
Tue Mar 7 16:06:16 2023, OST, Runs, , General,
|
run control = 46
run data =/onlineNEDA_00/xData/hil099/run_0046_07-03-2023_15h08m38s/needleRU_i46_0046_0004.caendat
RU = 6.51 MB/s
LF = 3.44 MB/s
plunger:
plunger run = 405
actual distance = 283 um
supposed distance = 282.7 um
micrometer = 285.9 um
position = 50 um
voltage = 2.966 V
Beam dump = 0.7 nA
Collimater= 0.5 nA |
Tue Mar 7 17:45:18 2023, IP, Runs, , General,
|
run control = 46
run data = /onlineNEDA_00/xData/hil099/run_0046_07-03-2023_15h08m38s/needleRU_i46_0046_0013.caendat
RU = 6.10 MB/s
LF = 3.26 MB/s
plunger:
plunger run = 422
actual distance = 282.6um
supposed distance = 282.7 um
micrometer = 284.9 um
position = 49.9 um
voltage = 2.968 V
Beam dump = 0.7 nA
Collimater= 0.5 nA |
Tue Mar 7 19:24:25 2023, IP, Runs, , General,
|
run control = 46
run data = /onlineNEDA_00/xData/hil099/run_0046_07-03-2023_15h08m38s/needleRU_i46_0046_0022.caendat
RU = 6.22 MB/s
LF = 3.34 MB/s
plunger:
plunger run = 439
actual distance = 282.5um
supposed distance = 282.7 um
micrometer = 284.9 um
position = 49.8 um
voltage = 2.97 V
Beam dump = 0.7 nA
Collimater= 0.5 nA |
Tue Mar 7 20:42:03 2023, IP, Problems, , Beam, beam unstable
|
There was a problem with the beam from 20:19 to 20:30.
Now it is fine. |
Tue Mar 7 20:45:13 2023, IP, Runs, , General,
|
run control = 46
run data =/onlineNEDA_00/xData/hil099/run_0046_07-03-2023_15h08m38s/needleRU_i46_0046_0028.caendat
RU = 4.9 MB/s
LF = 3.14 MB/s
plunger:
plunger run = 452
actual distance = 282.4 um
supposed distance = 282.7 um
micrometer = 284.7 um
position = 49.7 um
voltage = 2.971 V
Beam dump = 0.7 nA
Collimater= 0.5 nA |
Tue Mar 7 21:55:45 2023, IP, Runs, , General,
|
run control = 46
run data = /onlineNEDA_00/xData/hil099/run_0046_07-03-2023_15h08m38s/needleRU_i46_0046_0034.caendat
RU = 4.78 MB/s
LF = 3.10 MB/s
plunger:
plunger run = 464
actual distance = 282.8 um
supposed distance = 282.7 um
micrometer = 285.1 um
position = 49.9 um
voltage = 2.965 V
Beam dump = 0.7 nA
Collimater= 0.5 nA |
Tue Mar 7 23:39:52 2023, IP, KS, Runs, , General, run 46 stopped
|
Run 46 - stopped
- Run number: 46
- Start time: Tue Mar 7 15:09:06 2023
- Stop time: Tue Mar 7 23:38:07 2023
|
Tue Mar 7 23:54:05 2023, IP, KS, Runs, , General,
|
run control = 47
run data = /onlineNEDA_00/xData/hil099/run_0047_07-03-2023_23h42m03s/needleRU_i47_0047_0000.caendat
RU = 4.47 MB/s
LF = 3.26 MB/s
plunger:
plunger run = 484
actual distance = 282.8 um
supposed distance = 282.7 um
micrometer = 285.2 um
position = 50.1 um
voltage = 2.965 V
Beam dump = 0.7 nA
Collimater= 0.5 nA |
Wed Mar 8 00:31:05 2023, KS, KSz, Runs, , General, Run 47 standard info
|
run control = 47
run data = /onlineNEDA_00/xData/hil099/run_0047_07-03-2023_23h42m03s/needleRU_i47_0047_0003.caendat
RU = 5.12 MB/s
LF = 3.32 MB/s
plunger:
plunger run = 491
actual distance = 282.9 um
supposed distance = 282.7 um
micrometer = 285.12 um
position = 50.2 um
voltage = 2.963 V
Beam dump = 0.7 nA
Collimater= 0.5 nA |
Wed Mar 8 01:24:04 2023, BS, Runs, , General, Run 47 Stopped to Change Distance Change
|
Run 47 stopped and distance changed from 50 um (+ 100 um offset) to 150 um (+ 100 um offset)
Last plunger run for 50 um (+ 100 um offset) is 495 |
Wed Mar 8 01:24:58 2023, KS, KSz, Runs, , General, New run started 48 (new distance)
|
run control = 48
run data = /onlineNEDA_00/xData/hil099/run_0048_08-03-2023_01h08m57s/needleRU_i48_0048_0000.caendat
RU = 5.09 MB/s
LF = 3.15 MB/s
plunger:
plunger run = 498
actual distance = 382.7 um
supposed distance = 382.7 um
micrometer = 383.4 um
position = 149.7 um
voltage = 2.146 V
Beam dump = 0.7 nA
Collimater= 0.5 nA |
Wed Mar 8 02:45:53 2023, KS, KSz, Other, , Beam, increase in Counting Rates
|
Since 2:32 increased counting rate observed:
Sinde 3:45 decrease to 1.5 kHz ch4.
run control = 48
/onlineNEDA_00/xData/hil099/run_0048_08-03-2023_01h08m57s/needleRU_i48_0048_0007.caendat
run data =
RU = 8.69 MB/s
LF = 3.79 MB/s
Eagle Rated ch4: around 2.3 kHz
plunger: (2:48)
plunger run = 514
actual distance = 382.7 um
supposed distance = 382.7 um
micrometer = 383.5 um
position = 149.8 um
voltage = 2.144 V
Beam dump = 1.5 nA
Collimater= 0.5 nA |
Wed Mar 8 04:24:40 2023, KS, KSz, Runs, , General, Run 48
|
run control = 48
run data = /onlineNEDA_00/xData/hil099/run_0048_08-03-2023_01h08m57s/needleRU_i48_0048_0017.caendat
RU = 5.75 MB/s
LF = 3.21 MB/s
plunger:
plunger run = 530
actual distance = 382,7 um
supposed distance = 382.7 um
micrometer = 384.3 um
position = 150.3 um
voltage = 2.146 V
Beam dump = 1.5 nA
Collimater= 0.7 nA (?) |
Wed Mar 8 06:25:53 2023, KS, KSz, Runs, , General,
|
run control = 48
run data = /onlineNEDA_00/xData/hil099/run_0048_08-03-2023_01h08m57s/needleRU_i48_0048_0029.caendat
RU = 6.59 MB/s
LF = 3.35 MB/s
plunger:
plunger run = 550
actual distance = 382,5 um
supposed distance = 382.7 um
micrometer = 384.6 um
position = 149.8um
voltage = 2.146 V
Beam dump = 1.5 nA
Collimater= 0.7 nA (?) |
Wed Mar 8 07:30:15 2023, KS, KSz, Problems, , Beam, beam unstable
|
The beam was unstable from 7:18 to 7:25. |
Wed Mar 8 07:57:05 2023, IK, Problems, , Beam, beam unstable
|
The beam was unstable from 7:55. Stabilized around 8:03.
Counting rates are higher, EAGLE det4 went to ~2.5kHZ from ~2kHz (attached).
According to the operator, a bit of a tuning was done, current is 1nA.
run control = 48
run data = /onlineNEDA_00/xData/hil099/run_0048_08-03-2023_01h08m57s/needleRU_i48_0048_0041.caendat
RU = 10.4 MB/s
LF = 4.3 MB/s
|
Wed Mar 8 09:31:43 2023, IK, Runs, , General, Run 48 stopped, run 49 started
|
Run 48 stopped at 9:29 to start a new run.
Run 49 is started okay at 9:31.
run control = 49
run data = /onlineNEDA_00/xData/hil099/run_0048_08-03-2023_01h08m57s/needleRU_i48_0048_0041.caendat
RU = 10.1 MB/s
LF = 4.68MB/s
plunger:
plunger run = 582
actual distance = 383.1 um
supposed distance = 382.7 um
micrometer = 385.8 um
position = 150.5 um
voltage = 2.145 V
Beam dump 0.7 nA
|
Wed Mar 8 10:27:26 2023, IK, BS, Other, , General, Ge spectra
|
Count rates are still a bit high (~2.6kHz for EAGLE det4). Ge spectra looks fine compared to earlier ones.
|
Wed Mar 8 10:31:10 2023, IK, Runs, , General, Run 49
|
run control = 49
run data = /onlineNEDA_00/xData/hil099/run_0049_08-03-2023_09h31m08s/needleRU_i49_0049_0008.caendat
RU = 10.6 MB/s
LF = 4.89MB/s
plunger:
plunger run = 591
actual distance = 383.0 um
supposed distance = 382.7 um
micrometer = 385.8 um
position = 150.3 um
voltage = 2.145 V
Beam dump 0.7 nA
|