Sun Jun 18 03:45:22 2023, NM, MR, Problems, , General, Ru 17 stopped
|
Run 17 stopped because accelerator discharged
|
Sun Jun 18 02:57:23 2023, NM, MR, Runs, , General, Run 17 
|
ch0: 24.96V 10.87uA
ch2: 25.01V 6.26uA
ch3: 25.00V 4.86uA |
Sun Jun 18 01:30:21 2023, NM, MR, Other, , Other, Particle spectra
|
We observed a decrease in the particle energies. We attached one channel comparing with the same but from run 5. We keep running.
|
Sun Jun 18 00:56:12 2023, NM, MR, Runs, , General, run16 
|
File name : run
Run number : 16
User commentary : 62Ni on 197Au, intensity 4 enA |
Sat Jun 17 22:48:18 2023, DK, KS, Runs, , , run_15
|
Beam intensity - 5enA
ch0: 24.96V 10.94uA |
Sat Jun 17 20:56:44 2023, DK, KS, Runs, , General, run_14   
|
Beam intensity started at 20 enA, went to 8.5 enA and keep decreasing (up to 3enA), wriging ~5.3 KiB/s
Intensity dropped to 3enA, Hakim came and increased it back to 20enA from subrun 24-25 onward.
==> DAQ started at : 23-06-17 at 21h-08m-29s |
Sat Jun 17 20:42:04 2023, DK, KS, KHK, Problems, , tests, DSSD - channels S1 0-5 - efficiency drop
|
we reset the DAQ and did the module_restart with the card IP 192.168.3.78
no change
we restarted the HV DSSD - no change |
Sat Jun 17 20:31:59 2023, DK, KS, KHK, Runs, , , run_12
|
Restarted the DAQ:
File name : run
Run number : 12 |
Sat Jun 17 19:22:42 2023, DK, KS, KHK, Runs, , General, run_11
|
62Ni beam
ch0: 24.96V 11.05uA
ch2: 25.01V 6.05uA |
Sat Jun 17 18:10:45 2023, DK, KS, KHK, Runs, , General, run_10   
|
62Ni beam
ch0: 24.96V 11.05uA
ch2: 25.01V 6.05uA |
Sat Jun 17 16:04:34 2023, All, Runs, , General, run_9
|
62Ni beam
ch0: 24.96V 10.47uA
ch2: 25.01V 5.94uA |
Sat Jun 17 13:12:26 2023, KWL GC, Problems, , Other, swap between 62Ni and 58Ni beam for run 6 and 7
|
Attached is the particle-gated gamma-ray spectrum for run 5 (green), run 6 (blue), run7 (red).
In run 5 we see clearly transition of 2+1 --> 0+1 in 62Ni, while in run 6 both transitions are visible from 58Ni and 62Ni (which is a result
of a wrong beam tunning in to increase the intensity during which the ion changed by mistake). Now we are running with 58Ni (run 7) and waiting for |
Sat Jun 17 11:42:55 2023, All, Runs, , General, run_7
|
=> DAQ started at : 23-06-17 at 12h-07m-51s
==> Shell name : ./.user_start.sh   |
Sat Jun 17 09:26:42 2023, GC KWL KHK, Runs, , General, run_6
|
DSSD:
CH0: 9.7 uA
CH2: 5.525 uA |
Sat Jun 17 07:37:24 2023, KWL, JI, Runs, , General, run 5 62Ni (220 MeV) on 197Au taarget , 20 enA 
|
Beam untensity increased compared to the previous run . It is now 20 enA at the entrance to the chamber.
DSSD:
CH0: 9.81 uA |
Sat Jun 17 05:31:19 2023, KWL JI, Runs, , General, run_4   
|
DSSD:
CH0: 24.96 V 9.75 uA
CH2: 25.00 V 5.495 uA |
Sat Jun 17 03:25:08 2023, KWL, JI, KHK, Runs, , General, run_3   
|
DSSD:
ch0 24.95 V 9.8 uA
ch2 25 V 5.51 uA |
Fri Jun 16 14:33:10 2023, KHK, CH, Runs, , General, run_2
|
stop - the source is stopped - no beam
target position 6, 1.5 mg/cm2
data rate 5-6 MB/s |
Fri Jun 16 09:44:52 2023, KHK, GC, GL, Runs, , General, to be neglected in the analysis
|
test_noDSSD_62Ni_197Au.fast - run with the FC on, good for background (the beam was on but not on the target)
test_withDSSD_62Ni_197Au.fast - 58Ni beam on the target, E~210, intensity ~20 enA
test_withDSSD_62Ni_197Au_2.fast - 58Ni beam on the target, E~210, intensity ~20 enA |
Fri Jun 16 09:37:55 2023, GC KHK GL, Runs, , General, First run with 62Ni on the target
|
beam current 20 enA
charge state 17
energy is yet to be checked (tuned to 210 MeV of 58Ni, Alain has to recalculate and change to 230 MeV of 62Ni) |
|