Mon Mar 6 16:28:42 2023, Iolanda, pjn, Other, General, PARIS BIAS Voltages    
|
| |
Mon Mar 6 17:00:29 2023, All, , , Calibration with AmBeNi source for PARIS - part 2
|
Start 16:44
Start a second calibration run after changing the voltage offset of the FR1D5 (label 505) PARIS detector from 0.9 to 0.8.
Didn't recover detector FR1D8. Correlation matrix still look bad. |
Mon Mar 6 18:01:02 2023, pjn, Other, Other, Target changer problem
|
Target changet doesn't place taregts in a correct position.
There is no possibility to put a hole in a target position properly.
The chamber has to be oppened to fix it. |
Mon Mar 6 22:10:30 2023, KWL PJN, Other, General, target holder
|
Target holder - positions:
1 hole
2 quartz |
Tue Mar 7 01:16:15 2023, Desi, Michalina, , , No target run
|
Beam intensity is 0.3 enA
No target on the beam, test run with wheel position 1
Start 00:40 |
Tue Mar 7 01:56:12 2023, Desi, Michalina, , , Run_1
|
Run_1
Target position 4 - 208Pb 2 mg/cm^2
START: 01:52 |
Tue Mar 7 04:48:22 2023, Desi, Michalina, , , Run 2 
|
We checked if the target is okay before the start of this run.
On the camera it looked attached and not broken.
However we have trouble interpreting the spectra. Seems like the lines in 40Ca are missing |
Tue Mar 7 08:23:17 2023, pjn, Routine, General, run 4
|
start 8:20
beam cuurent: 0.3 enA
data stream 4.4 MB/s |
Tue Mar 7 09:06:31 2023, pjn, Routine, General, run 5
|
start 9:05
Energy too high for the digitisers
Gain changed from 6 to 5 on MDU-16s |
Tue Mar 7 05:59:17 2023, Desi, Michalina, , , Run 3
|
Start 06:00
|
Tue Mar 7 10:19:37 2023, pjn, , , Run 3
|
for runs 1-3 energy was to high
corrected in run 4
|
Tue Mar 7 15:32:02 2023, KWL PJN, Other, General, improving beam intensity and a note on the DSSD spectra  
|
Over a night 6/7 of March the beam intensity was very low , i.e. ~ 0.3 enA (compared to the 12 enA indicated in the proposal) and the beam energy
was higher than requested in the proposal.
We have requested for a higher beam intensity. The operators are trying to improve it now. |
Tue Mar 7 19:24:41 2023, Kasia WL, Kasia HK, PJN, , General, run with the empty frame
|
Hakim et al., played with the beam - they put the C cone and tested it - it worked for C but then it didn't work with Ca.
We decided to take the beam. First run is the test with the empty frame to see the background.
Current - 0.35 enA = 0.03 pnA |
Tue Mar 7 20:15:38 2023, pjn, Routine, General, run_6
|
Start 20:13
Stop 21:03
Beam current 0.25enA |
Tue Mar 7 21:05:10 2023, KWL KHK PJN MKOM, Other, General, run 7 - change target to 197Au
|
we stopped run 6 with 208Pb target and we change target to the 197Au in order to see the target excitation in gamma ray spectrum.
started at 21:10
beam intensity: 0.45 enA |
Tue Mar 7 22:39:36 2023, Kasia WL, Kasia HK, PJN, Other, , comaprison - Au and Pb targets 
|
We decided to change the target to 197Au, 2 mg/cm2 (pos 6) in order to check how the gamma spectra look like.
We obtained a very clean gamma spectrum compared to the one collected with Pb target. We concluded that the Pb target is probably contaminated
and it's also probably the effect of the frame size - Au target is mounted on a frame with a bigger hole than Pb, means that we could have seen also |
Tue Mar 7 23:35:38 2023, PJN MKOM, , , run_8
|
==> DAQ started at : 23-03-08 at 00h-01m-07s
==> Shell name : ./.user_start.sh &nbs |
Wed Mar 8 03:30:36 2023, MKOM, , , run_9
|
==> DAQ started at : 23-03-08 at 01h-55m-20s
==> Shell name : ./.user_start.sh &nbs |
Wed Mar 8 05:33:15 2023, MKOM, , , run_10
|
==> DAQ started at : 23-03-08 at 04h-08m-42s
==> Shell name : ./.user_start.sh &nbs |
Wed Mar 8 07:44:09 2023, MKOM, , , run_11
|
==> DAQ started at : 23-03-08 at 05h-59m-45s
==> Shell name : ./.user_start.sh
File name : run |
Wed Mar 8 07:45:21 2023, KHK, MKOM, , , run_12
|
Stopped because Hakim wants to change the source bottle to Ca - ammoniac
|