ID Date Authordown Type test Category Subject
  216   Fri Mar 10 21:15:01 2023 IPRuns General 

run control = 53

 

run data =/onlineNEDA_00/xData/hil099/run_0053_10-03-2023_16h18m36s/needleRU_i53_0053_0029.caendat

RU = 7.81 MB/s

LF =   3.94 MB/s

 

plunger:

plunger run = 1182

actual distance =  434.6 um

supposed distance = 435 um

micrometer =   436.4 um

position =  201.9 um

voltage =  1.934 V

 

Beam dump: 1 nA 

Colimator :  0.5 nA

  217   Fri Mar 10 21:24:29 2023 IPRuns Beamthe beam stopped

the beam is stopped at 21:23.

  218   Fri Mar 10 21:26:55 2023 IPProblems Beamproblem with focus the beam

the beam is not the best focused. The operator works on this problem.

  219   Fri Mar 10 21:29:28 2023 IPRuns Beambeam start

the beam starts at 21:27.

But the operators are still working on focusing the beam.

  220   Fri Mar 10 21:30:42 2023 IPProblem Fixed Beamthe beam is focused

the beam is now good focused

  221   Fri Mar 10 22:36:55 2023 IPRuns General 

run control = 53

 

run data = /onlineNEDA_00/xData/hil099/run_0053_10-03-2023_16h18m36s/needleRU_i53_0053_0037.caendat

RU = 7.62 MB/s

LF =   3.87 MB/s

 

plunger:

plunger run = 1196

actual distance =  435.7 um

supposed distance = 435 um

micrometer =   437.0 um

position =  203.0 um

voltage =  1.927 V

 

Beam dump: 1 nA 

Colimator :  0.5 nA

  222   Fri Mar 10 22:40:00 2023 IPOther GeneralGe - the rate is higher

the rates of detectors are still a bit higher

Quote:

From 13:00 the rate of the Ge [the chanel 4] is a bit higher (~2.15 kHz). And also the rate of other detectors.

 

 

Attachment 1: Screenshot_2023-03-10_22-37-27.png
Screenshot_2023-03-10_22-37-27.png
  223   Fri Mar 10 23:27:51 2023 IPProblems Softwarerun 53 - stopped

the daq crashed at 22:43 -- problem with Local Filter

the run 53 - stopped

  224   Fri Mar 10 23:29:43 2023 IPProblem Fixed Softwarenew run 54

the daq resolved at 23:15

start new run: run 54

  225   Fri Mar 10 23:35:28 2023 IPRuns General 

run control = 54

 

run data = run_0054_10-03-2023_23h14m24s/needleRU_i54_0054_0001.caendat

RU = 7.59 MB/s

LF =   3.55 MB/s

 

plunger:

plunger run = 1206

actual distance =  436.1 um

supposed distance = 435 um

micrometer =   437.1 um

position =  203.4 um

voltage =  1.925 V

 

Beam dump: 1 nA 

Colimator :  0.5 nA

  226   Sat Mar 11 00:05:06 2023 IPRuns Generalrun 54 - stopped

run 54 - stopped due to change the distance in plunger

  • Run number: 54
  • Start time: Fri Mar 10 23:14:54 2023
  • Stop time: Sat Mar 11 00:02:37 2023
  Draft   Mon Mar 23 03:03:54 2026 IPRuns Generalrun 54 - stopped

 

Quote:

run 54 - stopped due to change the distance in plunger

  • Run number: 54
  • Start time: Fri Mar 10 23:14:54 2023
  • Stop time: Sat Mar 11 00:02:37 2023

 

  63   Fri Mar 3 20:50:31 2023 IK, MP, GJOther Data analysisGe spectra

Ge rates increasing, similar to what it was 24h before. Asking to decrease beam intensity by a factor of 2.

Attached Ge spectra before decreasing.
 

Before decreas beam current was 1.75enA, afterwards 1.1enA.

Attachment 1: ge_rings101_117_143_Screenshot_2023-03-03_20-44-07.png
ge_rings101_117_143_Screenshot_2023-03-03_20-44-07.png
Attachment 2: Ge_rates_too_high.png
Ge_rates_too_high.png
  159   Wed Mar 8 10:27:26 2023 IK, BSOther GeneralGe spectra

Count rates are still a bit high (~2.6kHz for EAGLE det4). Ge spectra looks fine compared to earlier ones.


 

Attachment 1: Screenshot_2023-03-08_10-24-20.png
Screenshot_2023-03-08_10-24-20.png
  166   Wed Mar 8 15:57:53 2023 IK, AMProblems GeneralBeam issue

no beam in 15:52 - 16:21 due to power supply problem

  60   Fri Mar 3 16:47:29 2023 IKRuns GeneralRun 36 started

Run 36 Started

New Beam energy is 150 MeV

The beam dumb currennt is 2.5 enA.

Plunger run = 282

 

  61   Fri Mar 3 17:52:41 2023 IKProblem Fixed HardwareBeamdump readout issue - solved

Current readout issues from beamdump. Beam stopped from 17:46-17:52, run 36 ongoing.

MP & GJ checking the grounding and connection the beamdump readout. No visible issue found in the exp hall, but copper grounding wire was tightened, which seemingly resolved the issue (stability of beamdump readout).   

  62   Fri Mar 3 19:41:27 2023 IKProblems HardwareBeamdump readout issue Vol.2.

Issue described in #61 continues to persist.

Beam stopped from 19:20 to 19:32, run 36 ongoing; MP, GJ, BS entering the experimental hall. 

They changed the position of the grounding point on the chamber, moving it downstream after a fitting/joining part (A to B on the attached picture [artist: GJ]).

 

Attachment 1: 333626140_152534624340296_7230383118242592907_n.jpg
333626140_152534624340296_7230383118242592907_n.jpg
  Draft   Mon Mar 6 19:08:51 2023 IKRuns General 

RUN CONTROL = 42

Data =/onlineNEDA_00/xData/hil099/run_0042_06-03-2023_09h54m24s/needleRU_i42_0042_0045.caendat

RU = 6.95 MB/s

LF = 3.61 MB/s

Plunger ;

Plunger run = 196

Supposed Dist= 242.7 um

Micrometer = 245.2 um

Position = 9.7  um

Actual distance = 245.2 um

Voltage = 3.821 V

Beam dump = 1enA

 

  116   Mon Mar 6 20:29:45 2023 IKRuns General 

RUN CONTROL = 42

Data =/onlineNEDA_00/xData/hil099/run_0042_06-03-2023_09h54m24s/needleRU_i42_0042_0053.caendat

RU = 6.75 MB/s

LF = 3.54 MB/s

Plunger ;

Plunger run = 210

Supposed Dist= 242.7 um

Micrometer = 245.2 um

Position = 9.6  um

Actual distance = 242.3 um

Voltage = 4.184 V