EAGLE
IRRADIATIONS
EXTERNAL
Analysis
Students Workshop
Shift Plans
GAMMA-ONLY
NEEDLE NEEDI
COULEX
PLUNGER
GENERAL
HIL102-128Cs
HIL087-176Pt
Nd148_2
176Pt
HIL109-172Os
HIL124-128Cs
HIL061
Nd148
HIL106-119Cs
HIL097-118Xe
HIL099-134Sm
April16
xdaq
HIL099-134Sm, Page 10 of 15
New
|
Find
|
Config
|
Logout
Full
| Summary |
Threaded
-- All entries --
Last day
Last 3 Days
Last week
Last month
Last 3 Months
Last 6 Months
Last Year
-- Type --
Runs
Problems
Problem Fixed
Other
282 Entries
Goto page
Previous
1
,
2
,
3
...
9
, 10,
11
...
13
,
14
,
15
Next
All
ID
Date
Author
Type
test
Category
Subject
Text
216
Fri Mar 10 21:15:01 2023
IP
Runs
General
run control = 53
run data =/onlineNEDA_00/xData/hil099/run_0053_10-03-2023_16h18m36s/needleRU_i53_0053_0029.caendat
217
Fri Mar 10 21:24:29 2023
IP
Runs
Beam
the beam stopped
the beam is stopped at 21:23.
218
Fri Mar 10 21:26:55 2023
IP
Problems
Beam
problem with focus the beam
the beam is not the best focused. The operator
works on this problem.
219
Fri Mar 10 21:29:28 2023
IP
Runs
Beam
beam start
the beam starts at 21:27.
But the operators are still working
on focusing the beam.
220
Fri Mar 10 21:30:42 2023
IP
Problem Fixed
Beam
the beam is focused
the beam is now good focused
221
Fri Mar 10 22:36:55 2023
IP
Runs
General
run control = 53
run data = /onlineNEDA_00/xData/hil099/run_0053_10-03-2023_16h18m36s/needleRU_i53_0053_0037.caendat
222
Fri Mar 10 22:40:00 2023
IP
Other
General
Ge - the rate is higher
the rates of detectors are still a bit
higher
223
Fri Mar 10 23:27:51 2023
IP
Problems
Software
run 53 - stopped
the daq crashed at 22:43 -- problem with
Local Filter
the run 53 - stopped
224
Fri Mar 10 23:29:43 2023
IP
Problem Fixed
Software
new run 54
the daq resolved at 23:15
start new run: run 54
225
Fri Mar 10 23:35:28 2023
IP
Runs
General
run control = 54
run data = run_0054_10-03-2023_23h14m24s/needleRU_i54_0054_0001.caendat
226
Sat Mar 11 00:05:06 2023
IP
Runs
General
run 54 - stopped
run 54 - stopped due to change the distance
in plunger
Run number: 54
Start
Draft
Mon Mar 23 03:03:54 2026
IP
Runs
General
run 54 - stopped
63
Fri Mar 3 20:50:31 2023
IK, MP, GJ
Other
Data analysis
Ge spectra
Ge rates increasing, similar to what it
was 24h before. Asking to decrease beam intensity
by a factor of 2.
159
Wed Mar 8 10:27:26 2023
IK, BS
Other
General
Ge spectra
Count rates are still a bit high (~2.6kHz
for EAGLE det4). Ge spectra looks fine compared
to earlier ones.
166
Wed Mar 8 15:57:53 2023
IK, AM
Problems
General
Beam issue
no beam in 15:52 - 16:21 due to power supply
problem
60
Fri Mar 3 16:47:29 2023
IK
Runs
General
Run 36 started
Run 36 Started
New Beam energy is 150 MeV
The beam dumb currennt is 2.5 enA.
61
Fri Mar 3 17:52:41 2023
IK
Problem Fixed
Hardware
Beamdump readout issue - solved
Current readout issues from beamdump. Beam
stopped from 17:46-17:52, run 36 ongoing.
MP & GJ checking the grounding
62
Fri Mar 3 19:41:27 2023
IK
Problems
Hardware
Beamdump readout issue Vol.2.
Issue described in #61 continues to
persist.
Beam stopped from 19:20 to 19:32,
Draft
Mon Mar 6 19:08:51 2023
IK
Runs
General
RUN CONTROL = 42
Data =/onlineNEDA_00/xData/hil099/run_0042_06-03-2023_09h54m24s/needleRU_i42_0042_0045.caendat
RU = 6.95 MB/s
116
Mon Mar 6 20:29:45 2023
IK
Runs
General
RUN CONTROL = 42
Data =/onlineNEDA_00/xData/hil099/run_0042_06-03-2023_09h54m24s/needleRU_i42_0042_0053.caendat
RU = 6.75 MB/s
Goto page
Previous
1
,
2
,
3
...
9
, 10,
11
...
13
,
14
,
15
Next
All
ELOG V3.1.5-fc6679b