Entry  Wed Mar 8 13:04:05 2023, IK, Runs, , General, Ge spectra Screenshot_2023-03-08_13-03-10.png

Ge spectra after #161 - #162 beam tuning.

Entry  Wed Mar 8 13:02:38 2023, IK, Runs, , General, Run 49 

run control = 49

run data = /onlineNEDA_00/xData/hil099/run_0049_08-03-2023_09h31m08s/needleRU_i49_0049_0030.caendat

RU =  7.86 MB/s

LF =   3.87 MB/s

plunger:

plunger run = 616

actual distance =  382.7 um

supposed distance = 382.7 um

micrometer =   385.7 um

position =  150.0 um

voltage =  2.147 V

 

Beam dump 0.7 nA

 

 

 

 

 

 

Entry  Wed Mar 8 12:11:59 2023, IK, Problem Fixed, , General, beam tuned 

Beam tuning was made, focusing significantly improved.

 

Intensity:

beam dump: 0.9-1 nA,

collimator: 0.5 nA.

 

Rates:

RU =  8.2 MB/s

LF =   4.03 MB/s

EAGLE det4: 2.2 kHz

 

Entry  Wed Mar 8 11:42:14 2023, IK, Problems, , General, Run 49 Screenshot_2023-03-08_11-38-47.pngScreenshot_2023-03-08_11-38-19.pngScreenshot_2023-03-08_11-37-37.png

Counting rates continued to increase (det4 > 3kHz). Beam current looked fine on the beam dump, but beam is fluctuating, and can reach 2nA on the collimator.  Asked for improved focusing.

Attached screenshots and Ge spectra from before changing anything.

 

run control = 49

run data = /onlineNEDA_00/xData/hil099/run_0049_08-03-2023_09h31m08s/needleRU_i49_0049_0020.caendat

RU =  13.3 MB/s

LF =   6.15MB/s

plunger:

plunger run = 603

actual distance =  382.7 um

supposed distance = 382.7 um

micrometer =   385.9 um

position =  150.0 um

voltage =  2.146 V

 

Beam dump 0.7 nA

Collimator ~1.5-2nA when the generator retunes itself (prob the beam gets defocused at those moments)

 

 

 

 

 

Entry  Wed Mar 8 10:31:10 2023, IK, Runs, , General, Run 49 

run control = 49

run data = /onlineNEDA_00/xData/hil099/run_0049_08-03-2023_09h31m08s/needleRU_i49_0049_0008.caendat

RU =  10.6 MB/s

LF =   4.89MB/s

plunger:

plunger run = 591

actual distance =  383.0 um

supposed distance = 382.7 um

micrometer =   385.8 um

position =  150.3 um

voltage =  2.145 V

 

Beam dump 0.7 nA

 

 

 

 

 

 

Entry  Wed Mar 8 10:27:26 2023, IK, BS, Other, , General, Ge spectra Screenshot_2023-03-08_10-24-20.png

Count rates are still a bit high (~2.6kHz for EAGLE det4). Ge spectra looks fine compared to earlier ones.


 

Entry  Wed Mar 8 09:31:43 2023, IK, Runs, , General, Run 48 stopped, run 49 started 

Run 48 stopped at 9:29 to start a new run.

Run 49 is started okay at 9:31.

 

run control = 49

run data = /onlineNEDA_00/xData/hil099/run_0048_08-03-2023_01h08m57s/needleRU_i48_0048_0041.caendat

RU =  10.1 MB/s

LF =   4.68MB/s

plunger:

plunger run = 582

actual distance =  383.1 um

supposed distance = 382.7 um

micrometer =   385.8 um

position =  150.5 um

voltage =  2.145 V

 

Beam dump 0.7 nA

 

 

 

 

 

 

Entry  Wed Mar 8 07:57:05 2023, IK, Problems, , Beam, beam unstable Screenshot_2023-03-08_08-17-41.png

The beam was unstable from 7:55. Stabilized around 8:03.

Counting rates are higher, EAGLE det4 went to ~2.5kHZ from ~2kHz (attached).

According to the operator, a bit of a tuning was done, current is 1nA.

 

run control = 48

run data =  /onlineNEDA_00/xData/hil099/run_0048_08-03-2023_01h08m57s/needleRU_i48_0048_0041.caendat

RU =  10.4 MB/s

LF =   4.3 MB/s

 

 

 

 

Entry  Wed Mar 8 07:30:15 2023, KS, KSz, Problems, , Beam, beam unstable 

The beam was unstable from 7:18 to 7:25.

Entry  Wed Mar 8 06:25:53 2023, KS, KSz, Runs, , General,  

run control = 48

run data =  /onlineNEDA_00/xData/hil099/run_0048_08-03-2023_01h08m57s/needleRU_i48_0048_0029.caendat

RU =  6.59 MB/s

LF =   3.35 MB/s

plunger:

plunger run = 550

actual distance =  382,5 um

supposed distance = 382.7 um

micrometer =   384.6 um

position =  149.8um

voltage =  2.146 V

Beam dump =  1.5 nA

Collimater=  0.7 nA (?)

Entry  Wed Mar 8 04:24:40 2023, KS, KSz, Runs, , General, Run 48 

run control = 48

run data =  /onlineNEDA_00/xData/hil099/run_0048_08-03-2023_01h08m57s/needleRU_i48_0048_0017.caendat

RU =  5.75 MB/s

LF =   3.21 MB/s

plunger:

plunger run = 530

actual distance =  382,7 um

supposed distance = 382.7 um

micrometer =   384.3 um

position =  150.3 um

voltage =  2.146 V

Beam dump =  1.5 nA

Collimater=  0.7 nA (?)

Entry  Wed Mar 8 02:45:53 2023, KS, KSz, Other, , Beam, increase in Counting Rates  

Since 2:32 increased counting rate observed:

Sinde 3:45 decrease to 1.5 kHz ch4.

run control = 48

/onlineNEDA_00/xData/hil099/run_0048_08-03-2023_01h08m57s/needleRU_i48_0048_0007.caendat
run data =

RU =  8.69 MB/s

LF =   3.79 MB/s

Eagle Rated ch4: around 2.3 kHz

plunger: (2:48)

plunger run = 514

actual distance =  382.7 um

supposed distance = 382.7 um

micrometer =   383.5 um

position =  149.8 um

voltage =  2.144 V

 

Beam dump =  1.5 nA

Collimater=  0.5 nA

Entry  Wed Mar 8 01:24:58 2023, KS, KSz, Runs, , General, New run started 48 (new distance) 

run control = 48

run data = /onlineNEDA_00/xData/hil099/run_0048_08-03-2023_01h08m57s/needleRU_i48_0048_0000.caendat

RU =  5.09 MB/s

LF =   3.15 MB/s

plunger:

plunger run = 498

actual distance =  382.7 um

supposed distance = 382.7 um

micrometer =   383.4 um

position =  149.7 um

voltage =  2.146 V

 

Beam dump =  0.7 nA

Collimater=  0.5 nA

Entry  Wed Mar 8 01:24:04 2023, BS, Runs, , General, Run 47 Stopped to Change Distance Change 

Run 47 stopped and distance changed from 50 um (+ 100 um offset) to 150 um (+ 100 um offset)

Last plunger run for 50 um (+ 100 um offset) is 495

Entry  Wed Mar 8 00:31:05 2023, KS, KSz, Runs, , General, Run 47 standard info 

run control = 47

run data = /onlineNEDA_00/xData/hil099/run_0047_07-03-2023_23h42m03s/needleRU_i47_0047_0003.caendat

RU =  5.12 MB/s

LF =   3.32 MB/s

plunger:

plunger run = 491

actual distance =  282.9 um

supposed distance = 282.7 um

micrometer =   285.12 um

position =  50.2 um

voltage =  2.963 V

Beam dump =  0.7 nA

Collimater=  0.5 nA

Entry  Tue Mar 7 23:54:05 2023, IP, KS, Runs, , General,  

run control = 47

run data = /onlineNEDA_00/xData/hil099/run_0047_07-03-2023_23h42m03s/needleRU_i47_0047_0000.caendat

RU =  4.47 MB/s

LF =   3.26 MB/s

plunger:

plunger run = 484

actual distance =  282.8 um

supposed distance = 282.7 um

micrometer =   285.2 um

position =  50.1 um

voltage =  2.965 V

 

Beam dump =  0.7 nA

Collimater=  0.5 nA

Entry  Tue Mar 7 23:39:52 2023, IP, KS, Runs, , General, run 46 stopped 

Run 46 - stopped

  • Run number: 46
  • Start time: Tue Mar 7 15:09:06 2023
  • Stop time: Tue Mar 7 23:38:07 2023
Entry  Tue Mar 7 21:55:45 2023, IP, Runs, , General,  

run control = 46

run data = /onlineNEDA_00/xData/hil099/run_0046_07-03-2023_15h08m38s/needleRU_i46_0046_0034.caendat

RU =  4.78 MB/s

LF =   3.10 MB/s

plunger:

plunger run = 464

actual distance =  282.8 um

supposed distance = 282.7 um

micrometer =   285.1 um

position =  49.9 um

voltage =  2.965 V

Beam dump =  0.7 nA

Collimater=  0.5 nA

Entry  Tue Mar 7 20:45:13 2023, IP, Runs, , General,  

run control = 46

run data =/onlineNEDA_00/xData/hil099/run_0046_07-03-2023_15h08m38s/needleRU_i46_0046_0028.caendat

RU =  4.9 MB/s

LF =   3.14 MB/s

plunger:

plunger run = 452

actual distance =  282.4 um

supposed distance = 282.7 um

micrometer =   284.7 um

position =  49.7 um

voltage =  2.971 V

Beam dump =  0.7 nA

Collimater=  0.5 nA

Entry  Tue Mar 7 20:42:03 2023, IP, Problems, , Beam, beam unstable 

There was a problem with the beam from 20:19 to 20:30.

Now it is fine.