ID
Date
Author
Type
test
Category
Subject
Text
144
Tue Mar 7 20:42:03 2023
IP
Problems
Beam
beam unstable
There was a problem with the beam from
20:19 to 20:30.
Now it is fine.
143
Tue Mar 7 19:24:25 2023
IP
Runs
General
run control = 46
run data = /onlineNEDA_00/xData/hil099/run_0046_07-03-2023_15h08m38s/needleRU_i46_0046_0022.caendat
RU = 6.22 MB/s
142
Tue Mar 7 17:45:18 2023
IP
Runs
General
run control = 46
run data = /onlineNEDA_00/xData/hil099/run_0046_07-03-2023_15h08m38s/needleRU_i46_0046_0013.caendat
RU = 6.10 MB/s
141
Tue Mar 7 16:06:16 2023
OST
Runs
General
run control = 46
run data =/onlineNEDA_00/xData/hil099/run_0046_07-03-2023_15h08m38s/needleRU_i46_0046_0004.caendat
RU = 6.51 MB/s
140
Tue Mar 7 15:14:29 2023
OST
Problem Fixed
Software
Run 46 started-15_Ge and number 5 anticompton working now.
VME crate with CAEN digitizers was rebooted.
Run 46 started, number 15_Ge and
number 5 anticompton dedector working
139
Tue Mar 7 15:12:06 2023
OST
Problems
Software
run 45 stopped
14:30 pm to 15:00 run 45 crashed and stopped
138
Tue Mar 7 14:39:08 2023
BS
Other
General
Runlist File ScreenShot Accesses on 07 MArch at 14:38
137
Tue Mar 7 14:23:43 2023
BS
Other
General
RU and BU Rates
136
Tue Mar 7 14:07:33 2023
BS
Other
General
Run Files Number
/onlineNEDA_00/xData/hil099/run_0045_07-03-2023_09h14m17s/needleRU_i45_0045_0027.caendat
/onlineNEDA_00/xData/hil099/run_0045_07-03-2023_09h14m17s/needleLF_i44_0045_0010.adf
135
Tue Mar 7 14:03:20 2023
BS
Runs
General
Counting Rates
134
Tue Mar 7 13:51:17 2023
OST
Runs
General
run control = 45
not fixed number 15_Ge dedector
and number 5 anticompton.
133
Tue Mar 7 12:50:52 2023
OST
Runs
General
run control = 45
not fixed number 15_Ge dedector
and number 5 anticompton.
132
Tue Mar 7 11:19:54 2023
OST
Runs
General
run control = 45
not fixed number 15_Ge dedector
and number 5 anticompton.
131
Tue Mar 7 09:56:07 2023
OST
Problems
mechanics
Beam stopped and operators controlling number 15_Ge dedector.
130
Tue Mar 7 09:41:44 2023
OST
Problems
Software
number_Ge_15 dedector not taking data
after run 45 I reset all spectrums and
number_Ge_15 dedector not
taking data.
129
Tue Mar 7 09:24:53 2023
OST
Runs
General
run control = 45
run data =/onlineNEDA_00/xData/hil099/run_0045_07-03-2023_09h14m17s/needleRU_i45_0045_0000.caendat
RU = 6.92 MB/s
128
Tue Mar 7 09:20:53 2023
OST
Problem Fixed
Beam
run 45 start-local filter turn green
I started run 45, and local filter turn
green everything is ok.
127
Tue Mar 7 09:18:01 2023
OST
Problems
Beam
run number 44 crashed and local filter turned red-but data saved
9:08 local filter turned red. Both .caendat
and LF .adf files still incrementing.
Stopped run 44, started run 45, looks OK.
126
Tue Mar 7 07:21:04 2023
JD, DW
Runs
General
run control = 44
run data =/onlineNEDA_00/xData/hil099/run_0044_07-03-2023_03h15m45s/needleRU_i44_0044_0023.caendat
RU = 6.57 MB/s
125
Tue Mar 7 06:18:46 2023
JD, DW
Runs
General
run control = 44
run data =/onlineNEDA_00/xData/hil099/run_0044_07-03-2023_03h15m45s/needleRU_i44_0044_0017.caendat
RU =6.95 MB/s