EAGLE IRRADIATIONS EXTERNAL Analysis Students Workshop Shift Plans
GAMMA-ONLY NEEDLE NEEDI COULEX PLUNGER GENERAL
HIL102-128Cs HIL087-176Pt Nd148_2 176Pt HIL109-172Os HIL124-128Cs HIL061 Nd148 HIL106-119Cs HIL097-118Xe HIL099-134Sm April16 xdaq
  HIL099-134Sm, Page 6 of 14  ELOG logo
Entry  Sat Mar 11 19:14:35 2023, BS, Runs, , General, Rates Screenshot_2023-03-11_19-11-45.pngScreenshot_2023-03-11_19-11-24.png

Run files /onlineNEDA_00/xData/hil099/run_0055_11-03-2023_00h33m38s/needleRU_i55_0055_0114.caendat

Beam Dump = 0.7 nA

Run number 55

Plunger Distance = 500 um + offset

Plunger run 1402

Voltage 1.369 V

Entry  Sat Mar 11 22:27:08 2023, BS, Runs, , General, Rates Screenshot_2023-03-11_22-26-22.png

Rates 22:18 367Hz

Rates 22:22 4.78 kHz

And Now see the figure

 

Entry  Tue Mar 7 14:23:43 2023, BS, Other, , General, RU and BU Rates Screenshot_2023-03-07_14-22-35.png
 
Entry  Fri Mar 10 01:28:48 2023, AM, Problems, , Other, Plunger distance 

longer break during chane of plunger distance due to technical problem, you can not move plunger to larger distances, so now we are choosing smaller distance in the morning we ask the specialists
 

Entry  Sun Mar 12 22:52:36 2023, Bahadir Saygi, Other, , General, Plunger Run Files  134Sm_cont.zip134Sm.zip

Plunger run files for later to calculate error in the distance

Entry  Mon Feb 27 12:13:03 2023, MB, Other, , , Plunger Informations 

Off set of the plunger ~60 um

Distcal file   distcal01_vac

 

Entry  Thu Mar 2 17:23:53 2023, BS, Runs, , General, Plunger Informations 

Plunger Run : 48

Supposed Distance = 10 um

position of the target = 10 um

micrometer = 6.5 um

Voltage = 7.957 V

Plunger off set 60 um

Which means we are running 60 um + 10 um (read from position window of plunger) = 70 um.
 

Entry  Mon Mar 6 05:15:43 2023, JD, DW, Problems, , Beam, No beam 05:10:00 

No beam 05:10:00

Entry  Sun Mar 12 13:20:00 2023, EG, Problems, , , No Data 

For a split second a red "NO DATA" notification appeared in the top right corner of Counting rates dashboard.

It looks like it did not change anything in data collection.


 

Entry  Thu Mar 9 01:07:48 2023, WP, Runs, , General, New run started 50 (distance change) 

run control = 50

run data = /onlineNEDA_00/xData/hil099/run_0050_09-03-2023_00h50m28s/needleRU_i50_0050_0000.caendat

 

RU =  7.43MB/s

LF =   3.61 MB/s

plunger:

plunger run = 736

actual distance =  533 um

supposed distance = 532.7 um

micrometer =   533.5 um

position =  300 um

voltage =  1.657 V

 

Beam dump: 1-1.5 enA (oscillating)

Colimator :  0.6 enA

 

Entry  Wed Mar 8 01:24:58 2023, KS, KSz, Runs, , General, New run started 48 (new distance) 

run control = 48

run data = /onlineNEDA_00/xData/hil099/run_0048_08-03-2023_01h08m57s/needleRU_i48_0048_0000.caendat

RU =  5.09 MB/s

LF =   3.15 MB/s

plunger:

plunger run = 498

actual distance =  382.7 um

supposed distance = 382.7 um

micrometer =   383.4 um

position =  149.7 um

voltage =  2.146 V

 

Beam dump =  0.7 nA

Collimater=  0.5 nA

Entry  Tue Mar 7 00:54:40 2023, JD, DW, Runs, , General, New run started 43 

run control = 43

run data = /onlineNEDA_00/xData/hil099/run_0043_07-03-2023_00h50m41s/needleRU_i43_0043_0000.caendat

RU =  7.13 MB/s

LF = 3.7 MB/s

plunger:

plunger run = 254

actual distance = 282.7 um

supposed distance = 282.7 um

micrometer = 285.2 um

position = 50 um

voltage = 2.966 V

Beam dump =  1 nA

Collimater= 0.5 nA

 

 

Entry  Mon Mar 6 10:02:47 2023, OST, Problem Fixed, , General, New run started 42 

RUN CONTROL = 42

Data =/onlineNEDA_00/xData/hil099/run_0042_06-03-2023_09h54m24s/needleRU_i42_0042_0000.caendat

           /onlineNEDA_00/xData/hil099/run_0042_06-03-2023_09h54m24s/needleLF_i41_0042_0000.adf

RU =   6.01 MB/s

LF =   3.32 MB/s

Plunger ;

Plunger run = 105

Supposed Dist= 242.7 um

Micrometer =  246.1 um

Position =   9.9  um

Actual distance = 242.6 um

Voltage =  3.809  V

Beam dumb =  1.5 nA

Entry  Mon Feb 27 12:21:29 2023, MP, BS, Runs, , General, List of runs 
A list of runs, to be filled during the experiment is available here:
https://docs.google.com/spreadsheets/d/11tyI5pqYKJ-rMaYLuBIPZCClWz9Vu87W0R5AZc2srd8/edit?usp=sharing
Entry  Sun Feb 26 17:26:45 2023, GJ, Other, , General, List of participants 

To be filled in, with affiliation and email.

Presumably, for later publication purposes.
 

Alphabetically by family name, please.

Budak, Mustafa Guray - Gazi University, mbudak@gazi.edu.tr

Ciemała, Michał - IFJ PAN, Kraków, Poland - Michal.Ciemala@ifj.edu.pl

Deary, James, - University of West of Scotland - james.deary@uws.ac.uk

Fijałkowska, Aleksandra,  aleksandra.fijalkowska@fuw.edu.pl

Fransen' Christoph IKP JOELN  fransen@ikp.uni-koeln.de

Goasduff, Alain - INFN-LNL alain.goasduff@lnl.infn.it

Grębosz, Jurek - IFJ PAN, Kraków, Poland

Jaworski, Grzegorz - HIL UW, Poland - tatrofil@slcj.uw.edu.pl

O'Donnell, David - University of West of Scotland - david.odonnell@uws.ac.uk

Palacz, Marcin - HIL UW, Poland - palacz@slcj.uw.edu.pl

Piętka, Iwona - Faculty of Physics, UW - iz.pietka@student.uw.edu.pl

Poklepa, Wiktor - UW, Poland, w.poklepa@student.uw.edu.pl

Saygi, Bahadir - Ankara University, Turkey - bahadir.saygi@ankara.edu.tr

Solak, Krzysztof - UW Poland, krzysztof.solak@post.pl

Szlęzak, Klara - UW, Poland, k.szlezak@student.uw.edu.pl

Temiz, Omer Sefa - Ankara University, Turkey - omer.temiz.95@gmail.com

White, Dylan, - University of West of Scotland - dylan.white@uws.ac.uk

 

 

 

 

Entry  Fri Mar 3 23:38:28 2023, SP, Runs, , General, How different Ge count ge_en_cal_230303_2337.png

All germanium detecors look reasonable, as attached.

Entry  Wed Mar 8 17:59:38 2023, BS, Runs, , General, General 

run control = 49

run data = /onlineNEDA_00/xData/hil099/run_0049_08-03-2023_09h31m08s/needleRU_i49_0049_0058.caendat

RU =  9.83 MB/s

LF =   4.87 MB/s

plunger:

plunger run = 665

actual distance =  382.7 um

supposed distance = 382.7 um

micrometer =   384.4 um

position =  150.0 um

voltage =  2.148 V

 

Beam dump 1,25 ~ 1.5  nA

Entry  Thu Mar 9 02:14:09 2023, WP, Runs, , General, General 

run control = 50

run data = /onlineNEDA_00/xData/hil099/run_0050_09-03-2023_00h50m28s/needleRU_i50_0050_0008.caendat

 

 

RU =  7.24 MB/s

LF =   3.64 MB/s

plunger:

plunger run = 748

actual distance =  532.1 um

supposed distance = 532.7 um

micrometer =   532.9 um

position =  299.4 um

voltage =  1.66 V

 

Beam dump: 1-1.5 enA (oscillating)

Colimator :  0.6 enA

 

Entry  Thu Mar 9 03:14:39 2023, WP, Runs, , General, General 

run control = 50

run data = /onlineNEDA_00/xData/hil099/run_0050_09-03-2023_00h50m28s/needleRU_i50_0050_0015.caendat

 

 

RU =  6.91 MB/s

LF =   3.48 MB/s

plunger:

plunger run = 758

actual distance =  533.5 um

supposed distance = 532.7 um

micrometer =   533.1 um

position =  300.9 um

voltage =  1.658 V

 

Beam dump: 1-1.5 enA (oscillating)

Colimator :  0.6 enA

 

Entry  Thu Mar 9 04:17:21 2023, WP, Runs, , General, General 

run control = 50

run data = /onlineNEDA_00/xData/hil099/run_0050_09-03-2023_00h50m28s/needleRU_i50_0050_0022.caendat

 

 

RU =  7.48 MB/s

LF =   3.59 MB/s

plunger:

plunger run = 769

actual distance =  531.1 um

supposed distance = 532.7 um

micrometer =   533.7 um

position =  300.5 um

voltage =  1.655 V

 

Beam dump: 1-1.5 enA (oscillating)

Colimator :  0.6 enA

 

ELOG V3.1.5-fc6679b