Sat Mar 4 18:02:48 2023, mgb, Runs, , General,
|
UN CONTROL = 36
Run Data =/onlineNEDA_00/xData/hil099/run_0036_03-03-2023_16h47m35s/needleRU_i36_0036_0138.caendat
RU = 6.39 MB/s |
Sat Mar 4 17:09:13 2023, mgb, Runs, , General,
|
RUN CONTROL = 36
Run Data = /onlineNEDA_00/xData/hil099/run_0036_03-03-2023_16h47m35s/needleRU_i36_0036_0133.caendat
RU = 6.45 MB/s |
Sat Mar 4 16:06:19 2023, mgb, Runs, , General,
|
RUN CONTROL = 36
Run Data = /onlineNEDA_00/xData/hil099/run_0036_03-03-2023_16h47m35s/needleRU_i36_0036_0127.caendat
RU = 6.25 |
Sat Mar 4 15:02:54 2023, mgb, Runs, , General, running stable
|
RUN CONTROL = 36
Run Data = /onlineNEDA_00/xData/hil099/run_0036_03-03-2023_16h47m35s/needleRU_i36_0036_0122.caendat
RU = 5.99 |
Sat Mar 4 13:43:20 2023, OST, Runs, , General,
|
RUN CONTROL = 36
Data =/onlineNEDA_00/xData/hil099/run_0036_03-03-2023_16h47m35s/needleRU_i36_0036_0114.caendat
RU = 7.30 |
Sat Mar 4 12:34:52 2023, OST, Runs, , General,
|
RUN CONTROL = 36
Data =/onlineNEDA_00/xData/hil099/run_0036_03-03-2023_16h47m35s/needleRU_i36_0036_0107.caendat
RU = 6.17 |
Sat Mar 4 11:06:31 2023, OST, Runs, , General,
|
RUN CONTROL = 36
Data =/onlineNEDA_00/xData/hil099/run_0036_03-03-2023_16h47m35s/needleRU_i36_0036_0100.caendat
RU = 6.03 |
Sat Mar 4 09:51:32 2023, OST, Runs, , General,
|
RUN CONTROL = 36
Data =/onlineNEDA_00/xData/hil099/run_0036_03-03-2023_16h47m35s/needleRU_i36_0036_0094.caendat
RU = 6.43 |
Sat Mar 4 08:27:23 2023, OST, Runs, , General,
|
RUN CONTROL = 36
Data =/onlineNEDA_00/xData/hil099/run_0036_03-03-2023_16h47m35s/needleRU_i36_0036_0087.caendat
RU = 4.57 |
Fri Mar 3 23:38:28 2023, SP, Runs, , General, How different Ge count
|
| All germanium detecors look reasonable, as attached. |
Fri Mar 3 20:50:31 2023, IK, MP, GJ, Other, , Data analysis, Ge spectra 
|
Ge rates increasing, similar to what it was 24h before. Asking to decrease beam intensity by a factor of 2.
Attached Ge spectra before decreasing.
|
Fri Mar 3 19:41:27 2023, IK, Problems, , Hardware, Beamdump readout issue Vol.2.
|
Issue described in #61 continues to persist.
Beam stopped from 19:20 to 19:32, run 36 ongoing; MP, GJ, BS entering the experimental hall.
They changed the position of the grounding point on the chamber, moving it downstream after a fitting/joining part (A to B on the attached |
Fri Mar 3 17:52:41 2023, IK, Problem Fixed, , Hardware, Beamdump readout issue - solved
|
Current readout issues from beamdump. Beam stopped from 17:46-17:52, run 36 ongoing.
MP & GJ checking the grounding and connection the beamdump readout. No visible issue found in the exp hall, but copper grounding wire
was tightened, which seemingly resolved the issue (stability of beamdump readout). |
Fri Mar 3 16:47:29 2023, IK, Runs, , General, Run 36 started
|
Run 36 Started
New Beam energy is 150 MeV
The beam dumb currennt is 2.5 enA. |
Fri Mar 3 15:04:33 2023, KWL, Other, , General, run 35 stopped
|
| Run 35 stopped. An attempt to check if we can get 5 MeV higher beam energy. |
Fri Mar 3 14:22:12 2023, IP, Runs, , General,
|
the beam comes back. The run 35 is still going.
plunger run # 257 |
Fri Mar 3 13:54:41 2023, IP. KWL, Runs, , General, beam energy measurement
|
beam stop due to the beam energy measurement
The beam energy: ~145 MeV |
Fri Mar 3 13:43:56 2023, IP. KWL, Runs, , , 511 annihilation and 279 Au lines in Ge rings 
|
The counting rate in 511 keV line for sum of the Ge detectors placed at 101, 117 and 143 degrees (with approved ACS). The largest intensity is visible
for Ge at 143 degrees, lowest for 101 deg.
=============================== RING 101 |
Fri Mar 3 12:11:24 2023, IP, Runs, , General,
|
| the beam comes back. |
Fri Mar 3 11:48:29 2023, IP, Runs, , General, beam stopped
|
| The beam is gone. |
|