108
|
Mon Mar 6 10:02:47 2023 |
OST | Problem Fixed | | General | New run started 42 | RUN CONTROL = 42
Data =/onlineNEDA_00/xData/hil099/run_0042_06-03-2023_09h54m24s/needleRU_i42_0042_0000.caendat
|
|
|
121
|
Tue Mar 7 03:21:33 2023 |
JD, DW | Problem Fixed | | General | daq crash | daq crashed at 02:59:00, resolved at 03:16:00
|
|
|
128
|
Tue Mar 7 09:20:53 2023 |
OST | Problem Fixed | | Beam | run 45 start-local filter turn green | I started run 45, and local filter turn
green everything is ok. |
|
|
140
|
Tue Mar 7 15:14:29 2023 |
OST | Problem Fixed | | Software | Run 46 started-15_Ge and number 5 anticompton working now. | VME crate with CAEN digitizers was rebooted.
Run 46 started, number 15_Ge and
number 5 anticompton dedector working |
|
|
162
|
Wed Mar 8 12:11:59 2023 |
IK | Problem Fixed | | General | beam tuned | Beam tuning was made, focusing significantly
improved.
|
|
|
175
|
Thu Mar 9 01:41:50 2023 |
GJ | Problem Fixed | | Hardware | TS zeroing - cables to S-IN from VME controller - between runs 49 and 50 | Since we were observing jumps of 16 ns in
timings of all channels of whole boards,
the assumption was that the
|
|
|
215
|
Fri Mar 10 21:00:15 2023 |
IP | Problem Fixed | | Beam | the beam comes back | the beam comes back at 20:54 |
|
|
220
|
Fri Mar 10 21:30:42 2023 |
IP | Problem Fixed | | Beam | the beam is focused | the beam is now good focused |
|
|
224
|
Fri Mar 10 23:29:43 2023 |
IP | Problem Fixed | | Software | new run 54 | the daq resolved at 23:15
start new run: run 54 |
|
|
244
|
Sun Mar 12 00:09:35 2023 |
AF | Problem Fixed | | Software | caen_shifted correction in spy & greware | neda_psdcaen_positions.txt had weird values
for three first detectors, especially neda_02.
|
|
|
1
|
Sun Feb 26 16:50:56 2023 |
GJ | Other | | General | proposal | |
|
|
2
|
Sun Feb 26 17:26:45 2023 |
GJ | Other | | General | List of participants | To be filled in, with affiliation and email.
Presumably, for later publication
purposes. |
|
|
4
|
Mon Feb 27 12:10:24 2023 |
BS | Other | | Target | target | Support of Target = 1.5 mg/cm2 Ta
Target = 1.0 mg/cm2 Cd-106
Stopper = 10 mg/cm2 Au
|
|
|
5
|
Mon Feb 27 12:13:03 2023 |
MB | Other | | | Plunger Informations | Off set of the plunger ~60 um
Distcal file distcal01_vac
|
|
|
7
|
Tue Feb 28 23:08:35 2023 |
BS | Other | | | SHIFT LIST | https://docs.google.com/spreadsheets/d/1e2homI9RCYrg369z8aaY3VMIPgapUPOv0zKISsl58vQ/edit?usp=sharing
|
|
|
8
|
Tue Feb 28 23:10:36 2023 |
BS | Other | | | What we need to include for Plunger | Plunger Run :
Micrometer :
Supposed Distance: |
|
|
9
|
Wed Mar 1 00:14:28 2023 |
MP | Other | | Beam | beam energy | Beam energy measured: 148.2 MeV
Mind that this may be an overestimate (by
~1-2 MeV) |
|
|
15
|
Wed Mar 1 20:10:38 2023 |
BS, DOD | Other | | General | | Run 26 is going on but not much for the
moment in terms of any useful data.
And half of the EAGLE is opened. |
|
|
16
|
Wed Mar 1 21:59:45 2023 |
MB BS | Other | | General | | Offset of the plunger is 60 um.
new distcal01_vac_after_opening |
|
|
59
|
Fri Mar 3 15:04:33 2023 |
KWL | Other | | General | run 35 stopped | Run 35 stopped. An attempt to check if