EAGLE IRRADIATIONS EXTERNAL Analysis Students Workshop Shift Plans
GAMMA-ONLY NEEDLE NEEDI COULEX PLUNGER GENERAL
HIL102-128Cs HIL087-176Pt Nd148_2 176Pt HIL109-172Os HIL124-128Cs HIL061 Nd148 HIL106-119Cs HIL097-118Xe HIL099-134Sm April16 xdaq
  HIL099-134Sm, Page 3 of 14  ELOG logo
Entry  Thu Mar 2 17:23:53 2023, BS, Runs, , General, Plunger Informations 
Plunger Run : 48

Supposed Distance = 10 um

position of the target = 10 um
Entry  Thu Mar 2 17:25:36 2023, BS, Runs, , General, Run 32 Stopped 
Run 32 Stopped
Entry  Thu Mar 2 23:01:21 2023, A.T., Runs, , General, Run 34 started 
Run 34 Started (33 was stopped due to acquisition problems)

Plunger Run : 105

Supposed Distance = 10 um
Entry  Fri Mar 3 01:15:27 2023, mgb, Runs, , General,  
 

plunger run # 126

Earlier:   CUP#6  100 enA
Entry  Fri Mar 3 02:20:46 2023, mgb, Runs, , General,  
plunger run # 137

 

Beam dump 2.5 enA
Entry  Fri Mar 3 03:19:34 2023, mgb, Runs, , General,  
plunger run # 147

 

Beam dump 2.5 enA
Entry  Fri Mar 3 04:15:32 2023, mgb, Runs, , General,  
plunger run # 157

 

Beam dump 2.5 enA
Entry  Fri Mar 3 05:18:35 2023, OST, Runs, , General,  
plunger run # 167

 

Beam dump 2.5 enA
Entry  Fri Mar 3 06:24:03 2023, OST, Runs, , General,  
plunger run # 178

Beam dump 2.5 enA

Collimator  0.9 enA
Entry  Fri Mar 3 07:32:28 2023, OST, Runs, , General,  
plunger run # 188

Beam dump 2.5 enA

Collimator  0.8 enA
Entry  Fri Mar 3 08:20:13 2023, KWL, Runs, , General,  
plunger run # 196

Beam dump 1 enA (given by operators) * 7 (following entry ID#39) = 7 enA

Collimator   0.75  enA
Entry  Fri Mar 3 09:30:15 2023, IP. KWL, Runs, , General,  
plunger run # 208

Beam dump 0.75 enA (given by operators) * 7 (following entry ID#39) = 5.25 enA

Collimator   0.75  enA
Entry  Fri Mar 3 10:09:20 2023, IP. KWL, Runs, , General, beam intensity decreased to 0.3 enA (at beam dump) on our request  Ge_beamInten_03enA_differentYscale.pngGe_beamInten_03enA_sameYscale.png
// we noticed yesterday that GE at 143 degrees counts more than those placed at 117 and 101. The 511 keV line (+ background) is much more pronounced
for Ge at 143 degrees. To investigate this issue we decreased the beam intensity to 0.3 enA ( value given by operators at the beam dump ). 

Conclusion - decrease of the beam intensity does not explain above observations (se attached figs)
Entry  Fri Mar 3 10:21:18 2023, IP. KWL, Runs, , General, beam intensity back to 1.25 enA at the beam dump 
we increased beam intensity to 1.25 enA (readout at the beam dump)
Entry  Fri Mar 3 11:37:25 2023, IP, Runs, , General,  
plunger run # 230

Beam dump 1.2  enA (given by operators) * 7 (following entry ID#39) = 8.4 enA

Collimator   0.6  enA
Entry  Fri Mar 3 11:48:29 2023, IP, Runs, , General, beam stopped 
The beam is gone.
Entry  Fri Mar 3 12:11:24 2023, IP, Runs, , General,  
the beam comes back.
Entry  Fri Mar 3 13:54:41 2023, IP. KWL, Runs, , General, beam energy measurement 
beam stop due to the beam energy measurement

The beam energy: ~145 MeV
Entry  Fri Mar 3 14:22:12 2023, IP, Runs, , General,  
the beam comes back. The run 35 is still going.

 

plunger run # 257
Entry  Fri Mar 3 15:04:33 2023, KWL, Other, , General, run 35 stopped  
Run 35 stopped. An attempt to check if we can get 5 MeV  higher beam energy.
ELOG V3.1.5-fc6679b