ID |
Date |
Author |
Type |
test |
Category |
Subject |
|
265
|
Tue Jan 23 16:55:21 2024 |
yes | Other | | | 106Cd certificate |
|
|
264
|
Mon Mar 20 04:55:24 2023 |
MP | Other | | | missing caendat.bz2 on Bahadir's disk |
The following caendat.bz2 files were not copied to Bahadir's disks
(because they were not bzipped at the time of the copying):
run_0031_02-03-2023_16h04m28s
-rw-rw-r-- 1 xdaq xdaq 4294971272 Mar 2 16:15 needleRU_i31_0031_0000.caendat.bz2
-rw-rw-r-- 1 xdaq xdaq 769385912 Mar 2 16:17 needleRU_i31_0031_0001.caendat.bz2
run_0055_11-03-2023_00h33m38s
-rw-rw-r-- 1 xdaq xdaq 4294970584 Mar 11 20:09 needleRU_i55_0055_0124.caendat.bz2
-rw-rw-r-- 1 xdaq xdaq 4294974732 Mar 11 20:23 needleRU_i55_0055_0125.caendat.bz2
-rw-rw-r-- 1 xdaq xdaq 4294968200 Mar 11 20:33 needleRU_i55_0055_0126.caendat.bz2
-rw-rw-r-- 1 xdaq xdaq 4294969064 Mar 11 20:44 needleRU_i55_0055_0127.caendat.bz2
-rw-rw-r-- 1 xdaq xdaq 4294967332 Mar 11 20:56 needleRU_i55_0055_0128.caendat.bz2
-rw-rw-r-- 1 xdaq xdaq 4294967976 Mar 11 21:10 needleRU_i55_0055_0129.caendat.bz2
-rw-rw-r-- 1 xdaq xdaq 4294984456 Mar 11 21:21 needleRU_i55_0055_0130.caendat.bz2
-rw-rw-r-- 1 xdaq xdaq 4294973384 Mar 11 21:31 needleRU_i55_0055_0131.caendat.bz2
-rw-rw-r-- 1 xdaq xdaq 4294967428 Mar 11 21:42 needleRU_i55_0055_0132.caendat.bz2
-rw-rw-r-- 1 xdaq xdaq 4294968276 Mar 11 21:56 needleRU_i55_0055_0133.caendat.bz2
-rw-rw-r-- 1 xdaq xdaq 4294967576 Mar 11 22:10 needleRU_i55_0055_0134.caendat.bz2
-rw-rw-r-- 1 xdaq xdaq 4294983724 Mar 11 22:26 needleRU_i55_0055_0135.caendat.bz2
-rw-rw-r-- 1 xdaq xdaq 4294967932 Mar 11 22:39 needleRU_i55_0055_0136.caendat.bz2
-rw-rw-r-- 1 xdaq xdaq 4294967564 Mar 11 22:55 needleRU_i55_0055_0137.caendat.bz2
-rw-rw-r-- 1 xdaq xdaq 4294971848 Mar 11 23:05 needleRU_i55_0055_0138.caendat.bz2
-rw-rw-r-- 1 xdaq xdaq 4046574036 Mar 11 23:14 needleRU_i55_0055_0139.caendat.bz2
run_0058_12-03-2023_04h16m42s
-rw-rw-r-- 1 xdaq xdaq 4295004684 Mar 12 17:25 needleRU_i58_0058_0085.caendat.bz2
-rw-rw-r-- 1 xdaq xdaq 4295011036 Mar 12 17:33 needleRU_i58_0058_0086.caendat.bz2
-rw-rw-r-- 1 xdaq xdaq 4295019340 Mar 12 17:42 needleRU_i58_0058_0087.caendat.bz2
-rw-rw-r-- 1 xdaq xdaq 4294975440 Mar 12 17:50 needleRU_i58_0058_0088.caendat.bz2
-rw-rw-r-- 1 xdaq xdaq 4294968176 Mar 12 17:59 needleRU_i58_0058_0089.caendat.bz2
-rw-rw-r-- 1 xdaq xdaq 4294968016 Mar 12 18:09 needleRU_i58_0058_0090.caendat.bz2
-rw-rw-r-- 1 xdaq xdaq 4294968836 Mar 12 18:18 needleRU_i58_0058_0091.caendat.bz2
-rw-rw-r-- 1 xdaq xdaq 4294993728 Mar 12 18:27 needleRU_i58_0058_0092.caendat.bz2
-rw-rw-r-- 1 xdaq xdaq 4294967436 Mar 12 18:36 needleRU_i58_0058_0093.caendat.bz2
-rw-rw-r-- 1 xdaq xdaq 4295074884 Mar 12 18:46 needleRU_i58_0058_0094.caendat.bz2
-rw-rw-r-- 1 xdaq xdaq 3480562784 Mar 12 18:54 needleRU_i58_0058_0095.caendat.bz2
These files were bzipped only on 20/03/2023 |
|
263
|
Thu Mar 16 12:13:11 2023 |
MP | Other | | | test of radioactivity |
16/03/2023
Plunger chamber closed, some dummy target and stopper probably inside
run 72 eagle closed
run 73 right half of EAGLE completely opened
Three screenshots are attached:
Run 72 EAGLE closed
1) Three rings. There is significantly more 511 in ring 143 than in 117, 101
2) 5 detectors of ring 143. They all look similar to each other.
Run 73 right half of EAGLE opened
3) 5 detectors of ring 143. The 3 detectors in the opened half hardly see 511 keV, the other 2 do.
Check with Colibri and a gamma scintillator probe ws done: largest activity is visible close to the target chamber, in the region starting at the edge of the chamber, end ending about 6 cm upstream.
About 80 gamma counts/s are seen there. The count rate decreases further upstream.
Background rate: 20 to 30 counts/s, 25 counts/s in Sala Fizykow.
Radioactivity line seen in the spectra, with the same behaviour as 511: 743.5, 936 keV, 1434 keV. These are lines from 52Cr, fed by beta+ decay of 52Mn.
Confirmed by Michain gamma-gamma.
52Mn can be produced in the a2pn channel in the reaction 32S+27Al
|
|
262
|
Mon Mar 13 15:16:21 2023 |
MP | Other | | | list of files copied to Bahadir's disks |
Attached are the lists of files copied to the two 4 TB Bahadir's disks.
|
|
261
|
Mon Mar 13 12:16:31 2023 |
MP | Other | | | run 66 |
run 66 started, radiocativity (background)
|
|
260
|
Mon Mar 13 12:15:35 2023 |
MP | Other | | | measurement of radioactivity along the beam line |
At about 12:00, 13/03/2023 (about 17 hours after the beam was stopped), a measurement of activity of the beam line was performed using FH 40G-L10 meter.
Radioctivity run 65 stopped before the measurement, radioactivity run 66 started after the measurement
Background level 120 ns/h
Target, stopper, the forward half of the target chamber - dismounted.
Approximate distance from the target position (upstream), approximate activity
10 cm 500 ns/h
25 cm 420 ns/h
35 350 ns/h
40 350 ns/h
50 200 ns/h
75 170 ns/h
|
|
259
|
Sun Mar 12 22:52:36 2023 |
Bahadir Saygi | Other | | General | Plunger Run Files |
Plunger run files for later to calculate error in the distance |
|
258
|
Sun Mar 12 21:33:54 2023 |
GJ | Runs | | General | run 63 - 152 Eu during LN2 filling |
|
|
257
|
Sun Mar 12 20:55:08 2023 |
MP | Runs | | | runc62 152 for efficiency calibration |
started
source in the target position, as precisely as possible
|
|
256
|
Sun Mar 12 20:31:45 2023 |
GJ | Runs | | General | run_61 - target and stopper and beam dump dismounted. |
target and stopper and beam dump dismounted.
only the constructional elements of the plunger remained.
pure background, g trigger only.
Michal says the"bg" spectrum did not change... |
|
255
|
Sun Mar 12 19:20:37 2023 |
MP | Runs | | General | run 60, radioactivity, |
Run 59 collected data using gg trigger radioactivty
Run 60 trigger changed fropm gg to single g.
Just in the beginning a few minutes gg data could have been collected. |
|
254
|
Sun Mar 12 19:00:59 2023 |
OST | Runs | | General | Run 58 stopped and Run 59 started. |
18:54 Run 58 stopped and 18:55 Run 59 started.
BEAM STOPPED.
END of EXPERIMENT.
Run 59 collects radioactivity.
-rw-rw-r-- 1 xdaq xdaq 295178920 Mar 12 18:59 needleLF_i58_0059_0000.adf
-rw-rw-r-- 1 xdaq xdaq 802293316 Mar 12 18:59 needleRU_i59_0059_0000.caendat |
|
253
|
Sun Mar 12 18:50:37 2023 |
OST | Runs | | General | |
run control = 58
run data =xdaq 471656980 Mar 12 18:47 needleRU_i58_0058_0095.caendat
RU = 7.35 MB/s
LF = 3.50 MB/s
plunger:
plunger run = 1638
actual distance = 262.6 um
micrometer = 266.9 um
position = 29.8 um
voltage = 3.308 V
Beam dump: 0.7 nA
Colimator : 0.5 nA |
|
252
|
Sun Mar 12 17:03:12 2023 |
OST | Runs | | General | |
run control = 58
run data =xdaq 1111949504 Mar 12 17:01 needleRU_i58_0058_0083.caendat
RU = 7.14 MB/s
LF = 3.46 MB/s
plunger:
plunger run = 1620
actual distance = 262.5 um
micrometer = 266.7 um
position = 29.8 um
voltage = 3.31 V
Beam dump: 0.7 nA
Colimator : 0.5 nA |
|
251
|
Sun Mar 12 13:20:00 2023 |
EG | Problems | | | No Data |
For a split second a red "NO DATA" notification appeared in the top right corner of Counting rates dashboard.
It looks like it did not change anything in data collection.
|
|
250
|
Sun Mar 12 09:15:00 2023 |
EG | Other | | | Array_monitors mat refresh synchronization |
Beam stable, counting rate within limits, plunger distance within the given tollerance, gamma spectra ok, everything looks good but....
(yes there must be some "but"), refreshing of EAGLE_array_monitor.mat and NEDA_array_monitor.mat are out of sync. Mostly pure red colour is dysplayed. Not very usefull and (I suppose) missleading information.
|
|
249
|
Sun Mar 12 08:03:08 2023 |
OST | Runs | | General | |
run control = 58
run data = xdaq 3303602776 Mar 12 08:01 needleRU_i58_0058_0024.caendat
RU = 7.88 MB/s
LF = 3.70 MB/s
plunger:
plunger run = 1530
actual distance = 262.6 um
micrometer = 266.8 um
position = 29.9 um
voltage = 3.308 V
Beam dump: 1 nA
Colimator : 0.5 nA |
|
248
|
Sun Mar 12 07:01:31 2023 |
OST | Runs | | General | |
run control = 58
run data =xdaq 2254808224 Mar 12 06:59 needleRU_i58_0058_0017.caendat
RU = 8.10 MB/s
LF = 3.79 MB/s
plunger:
plunger run = 1520
actual distance = 262.7 um
micrometer = 266.7 um
position = 30 um
voltage = 3.306 V
Beam dump: 1 nA
Colimator : 0.5 nA |
|
247
|
Sun Mar 12 04:20:19 2023 |
OST | Runs | | General | Run 57 stopped, Run 58 started |
|
|
246
|
Sun Mar 12 03:23:05 2023 |
AF | Runs | | General | run_0057 |
run control = 57
run data =/onlineNEDA_00/xData/hil099/run_0057_12-03-2023_03h10m10s/
RU = 8.1 MB/s
LF = 3.8 MB/s
plunger:
plunger run = 1484
actual distance = 262.7 um
micrometer = 266.9 um
position = 30 um
voltage = 3.306 V
Beam dump: 0.75 nA
Colimator : 1.1 enA
stop: |
|
245
|
Sun Mar 12 03:05:45 2023 |
GJ, AF | Problems | | Network | no data flux visible in grafena, LF prints "write: Broken pipe" |
As in the title, see below.
The data are still being constantly written on the disks with usual rate (also visible on grafena).
Greware is also seeing data.
beeper output:
no new data about the growth for 37 s !!!
Noticed at Sun Mar 12 02:50:42 2023
and weirdo scream followed.
LF output:
write: Broken pipe
0-LF_neda_2: 98 ev ( 107153)*30 Tot=26234475 2253/s
write: Broken pipe
0-LF_eagle_1: 881 ev ( 120281)*31 Tot=295856141 24268/s
write: Broken pipe
write: Broken pipe
0-LF_neda_3: 3 ev ( 3909)*5980 Tot=375647125 30917/s
write: Broken pipe
0-LF_neda_1: 92 ev ( 92962)*40 Tot=32523205 2820/s
write: Broken pipe
write: Broken pipe
0-LF_neda_0: 104 ev ( 117997)*33 Tot=38078515 3323/s
0-LF_eagle_0: 720 ev ( 63994)*31 Tot=268339966 22243/s
write: Broken pipe
write: Broken pipe
write: Broken pipe
write: Broken pipe
write: Broken pipe
write: Broken pipe
0-LF_neda_2: 72 ev ( 87376)*31 Tot=26236761 2274/s
write: Broken pipe
0-LF_eagle_1: 714 ev ( 104681)*35 Tot=295880265 23988/s
write: Broken pipe
write: Broken pipe
0-LF_neda_3: 9 ev ( 3988)*5870 Tot=375677518 30545/s
write: Broken pipe
0-LF_neda_1: 93 ev ( 98610)*34 Tot=32525919 2698/s |
|
244
|
Sun Mar 12 00:09:35 2023 |
AF | Problem Fixed | | Software | caen_shifted correction in spy & greware |
neda_psdcaen_positions.txt had weird values for three first detectors, especially neda_02.
It was:
NEDA_00_position_psdcaen 0
NEDA_01_position_psdcaen 0.22
NEDA_02_position_psdcaen 40
I (AF) make it:
NEDA_00_position_psdcaen 0.2
NEDA_01_position_psdcaen 0.2
NEDA_02_position_psdcaen 0.2 |
|
243
|
Sat Mar 11 23:30:47 2023 |
AF | Runs | | General | run_0056 |
run control = 56
run data =/onlineNEDA_00/xData/hil099/run_0056_11-03-2023_23h26m10s
RU = 7.3 MB/s
LF = 3.5 MB/s
plunger:
plunger run = 1445
actual distance = 262.7 um
micrometer = 266.2 um
position = 30 um
voltage = 3.05 V
Beam dump: 0.75 nA
Colimator : 1.1 enA
stop: |
|
242
|
Sat Mar 11 22:52:48 2023 |
BS | Runs | | General | run_0055 |
run control = 55
run data = /onlineNEDA_00/xData/hil099/run_0055_11-03-2023_00h33m38s/needleRU_i55_0055_0137.caendat
RU = 4.17 MB/s
LF = 3.11 MB/s
plunger:
plunger run = 1439
actual distance = 515 um
micrometer = 578.2 um
position = 282.3 um
voltage = 1.372 V
Beam dump: 0.75 nA
Colimator : 1.1 enA
stop: 11.15 pm -> new plunger distance
|
|
241
|
Sat Mar 11 22:27:08 2023 |
BS | Runs | | General | Rates |
Rates 22:18 367Hz
Rates 22:22 4.78 kHz
And Now see the figure
|
|
240
|
Sat Mar 11 21:24:04 2023 |
OST | Runs | | General | |
run control = 55
run data = /onlineNEDA_00/xData/hil099/run_0055_11-03-2023_00h33m38s/needleRU_i55_0055_0129.caendat
RU = 6.45 MB/s
LF = 3.46 MB/s
plunger:
plunger run = 1424
actual distance = 515 um
supposed distance = 435 um
micrometer = 578.2 um
position = 282.3 um
voltage = 1.372 V
Beam dump: 1 nA
Colimator : 0.5 nA |
|
239
|
Sat Mar 11 19:14:35 2023 |
BS | Runs | | General | Rates |
Run files /onlineNEDA_00/xData/hil099/run_0055_11-03-2023_00h33m38s/needleRU_i55_0055_0114.caendat
Beam Dump = 0.7 nA
Run number 55
Plunger Distance = 500 um + offset
Plunger run 1402
Voltage 1.369 V |
|
238
|
Sat Mar 11 18:10:06 2023 |
OST | Runs | | General | |
run control = 55
run data = /onlineNEDA_00/xData/hil099/run_0055_11-03-2023_00h33m38s/needleRU_i55_0055_0114.caendat
RU = 5.72 MB/s
LF = 3.27 MB/s
plunger:
plunger run = 1392
actual distance = 512.2 um
supposed distance = 435 um
micrometer = 578.2 um
position = 279.5 um
voltage = 1.37 V
Beam dump: 0.9 nA
Colimator : 0.5 nA |
|
237
|
Sat Mar 11 18:06:36 2023 |
OST | Runs | | Beam | |
beam started 18:04. |
|
236
|
Sat Mar 11 17:58:35 2023 |
OST | Runs | | Beam | |
beam stopped 17:54. |
|
235
|
Sat Mar 11 16:22:06 2023 |
OST | Runs | | General | |
run control = 55
run data = /onlineNEDA_00/xData/hil099/run_0055_11-03-2023_00h33m38s/needleRU_i55_0055_0103.caendat
RU = 8.23 MB/s
LF = 4 MB/s
plunger:
plunger run = 1374
actual distance = 520.8 um
supposed distance = 435 um
micrometer = 578.2 um
position = 288.1 um
voltage = 1.377 V
Beam dump: 1 nA
Colimator : 0.6 nA |
|
234
|
Sat Mar 11 15:16:31 2023 |
EG | Other | | | Beam intensity reduced again |
Again beam intensity to high. Reduced to 2 kHz on ch4 GE |
|
233
|
Sat Mar 11 14:42:28 2023 |
EG | Runs | | | Beam instabilities |
Large beam intensity instabilities from 14:10 till 14:40. Beam intensity reduction requested. CH4 on Total rate EAGLE_0 returned to 1.9kHz. Intensity became stable.
|
|
232
|
Sat Mar 11 14:15:55 2023 |
EG | Runs | | | Beam intensity rapid increase |
14:12 beam intensity instability. Rapid increase of beam intensity - twice the previous value. Returned to normal after 4 minutes. |
|
231
|
Sat Mar 11 12:42:42 2023 |
EG | Other | | | Beam intensity reduction |
Again beam intensity gradually increased reaching 2.4 kHz ontotal rate EAGLE_0 ch4. Beam intensity reduction requested. 1.8 kHz on ch4 after reduction. |
|
230
|
Sat Mar 11 11:39:55 2023 |
EG | Problems | | | Buffers clearing |
at 11:34:50 sek on 11 march a spike in counting rate of some Ge detectors is observed. Buffers not cleared properly?
|
|
229
|
Sat Mar 11 10:46:37 2023 |
EG | Other | Beam intensity | | |
ch4 in total rate EGALE_) reached 2.4 kHz, beam intensity has been reduced to fit the required 2kHz.
|
|
228
|
Sat Mar 11 09:29:48 2023 |
EG | Other | | | current exeriment parameters as requested in the manual for shifters |
41_ge_single_theta 101,117,143 looks ok. No peakdeformation of 511, other gammas FWHM around half of that of511 - ok
ch4 in total rate EAGLE_0 arouns 2.1 kHz - ok
planger tollerace limits (green and blue horizontal markers) set far of the current distance, intantionally?
|
|
227
|
Sat Mar 11 00:34:51 2023 |
BS | Runs | | General | Run 55 Started New Distance 500 um |
Run 55 Started New Distance 500 um |
|
226
|
Sat Mar 11 00:05:06 2023 |
IP | Runs | | General | run 54 - stopped |
run 54 - stopped due to change the distance in plunger
- Run number: 54
- Start time: Fri Mar 10 23:14:54 2023
- Stop time: Sat Mar 11 00:02:37 2023
|
|
225
|
Fri Mar 10 23:35:28 2023 |
IP | Runs | | General | |
run control = 54
run data = run_0054_10-03-2023_23h14m24s/needleRU_i54_0054_0001.caendat
RU = 7.59 MB/s
LF = 3.55 MB/s
plunger:
plunger run = 1206
actual distance = 436.1 um
supposed distance = 435 um
micrometer = 437.1 um
position = 203.4 um
voltage = 1.925 V
Beam dump: 1 nA
Colimator : 0.5 nA |
|
224
|
Fri Mar 10 23:29:43 2023 |
IP | Problem Fixed | | Software | new run 54 |
the daq resolved at 23:15
start new run: run 54 |
|
223
|
Fri Mar 10 23:27:51 2023 |
IP | Problems | | Software | run 53 - stopped |
the daq crashed at 22:43 -- problem with Local Filter
the run 53 - stopped |
|
222
|
Fri Mar 10 22:40:00 2023 |
IP | Other | | General | Ge - the rate is higher |
the rates of detectors are still a bit higher
| Quote: |
|
From 13:00 the rate of the Ge [the chanel 4] is a bit higher (~2.15 kHz). And also the rate of other detectors.
|
|
|
221
|
Fri Mar 10 22:36:55 2023 |
IP | Runs | | General | |
run control = 53
run data = /onlineNEDA_00/xData/hil099/run_0053_10-03-2023_16h18m36s/needleRU_i53_0053_0037.caendat
RU = 7.62 MB/s
LF = 3.87 MB/s
plunger:
plunger run = 1196
actual distance = 435.7 um
supposed distance = 435 um
micrometer = 437.0 um
position = 203.0 um
voltage = 1.927 V
Beam dump: 1 nA
Colimator : 0.5 nA |
|
220
|
Fri Mar 10 21:30:42 2023 |
IP | Problem Fixed | | Beam | the beam is focused |
the beam is now good focused |
|
219
|
Fri Mar 10 21:29:28 2023 |
IP | Runs | | Beam | beam start |
the beam starts at 21:27.
But the operators are still working on focusing the beam. |
|
218
|
Fri Mar 10 21:26:55 2023 |
IP | Problems | | Beam | problem with focus the beam |
the beam is not the best focused. The operator works on this problem. |
|
217
|
Fri Mar 10 21:24:29 2023 |
IP | Runs | | Beam | the beam stopped |
the beam is stopped at 21:23. |
|
216
|
Fri Mar 10 21:15:01 2023 |
IP | Runs | | General | |
run control = 53
run data =/onlineNEDA_00/xData/hil099/run_0053_10-03-2023_16h18m36s/needleRU_i53_0053_0029.caendat
RU = 7.81 MB/s
LF = 3.94 MB/s
plunger:
plunger run = 1182
actual distance = 434.6 um
supposed distance = 435 um
micrometer = 436.4 um
position = 201.9 um
voltage = 1.934 V
Beam dump: 1 nA
Colimator : 0.5 nA |
|
215
|
Fri Mar 10 21:00:15 2023 |
IP | Problem Fixed | | Beam | the beam comes back |
the beam comes back at 20:54 |
|
214
|
Fri Mar 10 20:54:20 2023 |
IP | Problems | | Beam | lost the beam |
the beam was lost at 20:46. The operator is working to solve the problem. |
|
213
|
Fri Mar 10 19:42:57 2023 |
IP | Runs | | General | |
run control = 53
run data =/onlineNEDA_00/xData/hil099/run_0053_10-03-2023_16h18m36s/needleRU_i53_0053_0020.caendat
RU = 6.77 MB/s
LF = 3.64 MB/s
plunger:
plunger run = 1167
actual distance = 434.4 um
supposed distance = 435 um
micrometer = 437.2 um
position = 201.0 um
voltage = 1.934 V
Beam dump: 1 nA (sometimes increase to 1.5 nA)
Colimator : 0.5 nA |
|
212
|
Fri Mar 10 19:32:01 2023 |
IP | Runs | | Beam | start beam |
the beam start: 19:31 |
|
211
|
Fri Mar 10 19:30:48 2023 |
IP | Runs | | Beam | stop beam |
the beam was stopped at 19:27
|
|
210
|
Fri Mar 10 18:42:02 2023 |
IP | Runs | | General | |
run control = 53
run data = /onlineNEDA_00/xData/hil099/run_0053_10-03-2023_16h18m36s/needleRU_i53_0053_0014.caendat
RU = 7.41 MB/s
LF = 3.34 MB/s
plunger:
plunger run = 1157
actual distance = 434.4 um
supposed distance = 435.0 um
micrometer = 436.8 um
position = 201.7 um
voltage = 1.931 V
Beam dump: 1 nA (sometimes increase to 1.5 nA)
Colimator : 0.5 nA |
|
209
|
Fri Mar 10 17:34:07 2023 |
IP | Runs | | General | |
run control = 53
run data = /onlineNEDA_00/xData/hil099/run_0053_10-03-2023_16h18m36s/needleRU_i53_0053_0007.caendat
RU = 8.24 MB/s
LF = 4.10 MB/s
plunger:
plunger run = 1146
actual distance = 434.7 um
supposed distance = 435.0 um
micrometer = 436.5 um
position = 202.0 um
voltage = 1.932 V
Beam dump: 1 nA
Colimator : 0.5 nA |
|
208
|
Fri Mar 10 16:23:21 2023 |
IP | Runs | | General | |
run control = 53
run data = /onlineNEDA_00/xData/hil099/run_0053_10-03-2023_16h18m36s/needleRU_i53_0053_0000.caendat
RU = 7.12 MB/s
LF = 3.50 MB/s
plunger:
plunger run = 1134
actual distance = 434.3 um
supposed distance = 435.0 um
micrometer = 436.2 um
position = 201.6 um
voltage = 1.932 V
Beam dump: 1 nA
Colimator : 0.5 nA |
|
207
|
Fri Mar 10 16:17:57 2023 |
IP | Runs | | General | run 52 - stopped |
run 52 - stopped
- Run number: 52
- Start time: Fri Mar 10 01:19:56 2023
- Stop time: Fri Mar 10 16:16:25 2023
|
|
206
|
Fri Mar 10 16:14:19 2023 |
IP | Other | | General | Ge - the rate is higher |
From 13:00 the rate of the Ge [the chanel 4] is a bit higher (~2.15 kHz). And also the rate of other detectors.
|
|
205
|
Fri Mar 10 15:04:16 2023 |
OST | Runs | | General | |
run control = 52
run data = /onlineNEDA_00/xData/hil099/run_0052_10-03-2023_01h19m26s/needleRU_i52_0052_0074.caendat
RU = 7.17 MB/s
LF = 3.51 MB/s
plunger:
plunger run = 1120
actual distance = 434.8 um
supposed distance = 435.0 um
micrometer = 436.2 um
position = 202.1 um
voltage = 1.93 V
Beam dump: 1 nA
Colimator : 0.5 nA |
|
204
|
Fri Mar 10 13:35:49 2023 |
OST | Runs | | General | |
run control = 52
run data = /onlineNEDA_00/xData/hil099/run_0052_10-03-2023_01h19m26s/needleRU_i52_0052_0064.caendat
RU = 7.06 MB/s
LF = 3.35 MB/s
plunger:
plunger run = 1105
actual distance = 434.5 um
supposed distance = 435.0 um
micrometer = 436.4 um
position = 201.8 um
voltage = 1.931 V
Beam dump: 1 nA
Colimator : 0.5 nA |
|
203
|
Fri Mar 10 11:36:23 2023 |
OST | Runs | | General | |
run control = 52
run data = /onlineNEDA_00/xData/hil099/run_0052_10-03-2023_01h19m26s/needleRU_i52_0052_0053.caendat
RU = 5.69 MB/s
LF = 3.22 MB/s
plunger:
plunger run = 1087
actual distance = 434.2 um
supposed distance = 435.0 um
micrometer = 437.2 um
position = 203.5 um
voltage = 1.934 V
Beam dump: 2.5 nA
Colimator : 0.5 nA |
|
202
|
Fri Mar 10 10:03:36 2023 |
OST | Runs | | General | |
run control = 52
run data = /onlineNEDA_00/xData/hil099/run_0052_10-03-2023_01h19m26s/needleRU_i52_0052_0045.caendat
RU = 6.18 MB/s
LF = 3.24 MB/s
plunger:
plunger run = 1060
actual distance = 434.6 um
supposed distance = 435.0 um
micrometer = 435.1 um
position = 201.3 um
voltage = 1.934 V
Beam dump: 1 nA
Colimator : 0.5 nA |
|
201
|
Fri Mar 10 10:02:30 2023 |
OST | Runs | | General | |
run control = 52
run data = /onlineNEDA_00/xData/hil099/run_0052_10-03-2023_01h19m26s/needleRU_i52_0052_0045.caendat
RU = 6.18 MB/s
LF = 3.24 MB/s
plunger:
plunger run = 1060
actual distance = 434.6 um
supposed distance = 435.0 um
micrometer = 435.1 um
position = 201.3 um
voltage = 1.934 V
Beam dump: 1 nA
Colimator : 0.5 nA |
|
200
|
Fri Mar 10 08:02:39 2023 |
AM | Problems | | Beam | bigger data rate |
rate of ch4 above 2kHz, too big beam intesivity, highier data rate from: 07:51
|
|
199
|
Fri Mar 10 07:03:54 2023 |
AM | Runs | | General | |
run control = 52
run data = /onlineNEDA_00/xData/hil099/run_0052_10-03-2023_01h19m26s/needleRU_i52_0052_0029.caendat
RU = 6.06 MB/s
LF = 3.29 MB/s
plunger:
plunger run = 1040
actual distance = 434.3 um
supposed distance = 435.0 um
micrometer = 435.7 um
position = 201.6 um
voltage = 1.932 V
Beam dump: 1 nA
Colimator : 0.3/0.4 enA |
|
198
|
Fri Mar 10 05:40:34 2023 |
AM | Runs | | General | |
run control = 52
run data = /onlineNEDA_00/xData/hil099/run_0052_10-03-2023_01h19m26s/needleRU_i52_0052_0022.caendat
RU = 6.59 MB/s
LF = 3.49 MB/s
plunger:
plunger run = 1026
actual distance = 433.8 um
supposed distance = 435.0 um
micrometer = 435.0 um
position = 201.1 um
voltage = 1.934 V
Beam dump: 1 nA
Colimator : 0.3/0.4 enA |
|
197
|
Fri Mar 10 03:20:42 2023 |
AM | Runs | | General | |
run control = 52
run data = /onlineNEDA_00/xData/hil099/run_0052_10-03-2023_01h19m26s/needleRU_i52_0052_0010.caendat
RU = 5.55 MB/s
LF = 3.25 MB/s
plunger:
plunger run = 1002
actual distance = 434.3 um
supposed distance = 435.0 um
micrometer = 435.6 um
position = 201.6 um
voltage = 1.932 V
Beam dump: 1 nA
Colimator : 0.3/0.4 enA
|
|
196
|
Fri Mar 10 01:32:20 2023 |
AM | Runs | | General | run 51 stopped |
run 51 stopped
- Run number: 51
- Start time: Thu Mar 9 16:25:00 2023
- Stop time: Fri Mar 10 00:13:21 2023
run control = 52
run data = /onlineNEDA_00/xData/hil099/run_0052_10-03-2023_01h19m26s/needleRU_i52_0052_0000.caendat
RU = 6.02 MB/s
LF = 3.25 MB/s
plunger:
plunger run = 985
actual distance = 435.1 um
supposed distance = 435.0 um
micrometer = 435.9 um
position = 202.4 um
voltage = 1.929 V
Beam dump: 1 nA
Colimator : 0.3/0.4 enA |
|
195
|
Fri Mar 10 01:28:48 2023 |
AM | Problems | | Other | Plunger distance |
longer break during chane of plunger distance due to technical problem, you can not move plunger to larger distances, so now we are choosing smaller distance in the morning we ask the specialists
|
|
194
|
Fri Mar 10 00:09:32 2023 |
AM | Runs | | General | |
run control = 51
run data = /onlineNEDA_00/xData/hil099/run_0051_09-03-2023_16h25m16s/needleRU_i51_0051_0040.caendat
RU = 5.56 MB/s
LF = 3.24 MB/s
plunger:
plunger run = 969
actual distance = 532.3 um
supposed distance = 532.7 um
micrometer = 533.4 um
position = 300.5 um
voltage = 1.658 V
Beam dump: 1 nA
Colimator : 0.6 enA |
|
193
|
Thu Mar 9 22:32:01 2023 |
IP | Runs | | General | |
run control = 51
run data = /onlineNEDA_00/xData/hil099/run_0051_09-03-2023_16h25m16s/needleRU_i51_0051_0032.caendat
RU = 6.12 MB/s
LF = 3.42 MB/s
plunger:
plunger run = 952
actual distance = 533.2 um
supposed distance = 532.7 um
micrometer = 533.7 um
position = 300.5 um
voltage = 1.656 V
Beam dump: 1 nA
Colimator : 0.6 enA |
|
192
|
Thu Mar 9 21:20:06 2023 |
IP | Runs | | General | |
run control = 51
run data = /onlineNEDA_00/xData/hil099/run_0051_09-03-2023_16h25m16s/needleRU_i51_0051_0026.caendat
RU = 6.23MB/s
LF = 3.56 MB/s
plunger:
plunger run = 940
actual distance = 532.2 um
supposed distance = 532.7 um
micrometer = 533.0 um
position = 299.5 um
voltage = 1.659 V
Beam dump: 1 nA
Colimator : 0.6 enA |
|
191
|
Thu Mar 9 19:58:02 2023 |
IP | Runs | | General | |
run control = 51
run data = /onlineNEDA_00/xData/hil099/run_0051_09-03-2023_16h25m16s/needleRU_i51_0051_0018.caendat
RU = 5.93 MB/s
LF = 3.44 MB/s
plunger:
plunger run = 927
actual distance = 533.3 um
supposed distance = 532.7 um
micrometer = 533.0 um
position = 300.0 um
voltage = 1.656 V
Beam dump: 1 nA
Colimator : 0.6 enA |
|
190
|
Thu Mar 9 17:57:41 2023 |
MW | Runs | | General | |
run control = 51
run data = /onlineNEDA_00/xData/hil099/run_0051_09-03-2023_16h25m16s/needleRU_i51_0051_0007.caendat
RU = 6.45MB/s
LF = 3.47 MB/s
plunger:
plunger run = 907
actual distance = 532.8 um
supposed distance = 532.7 um
micrometer = 533.0 um
position = 299.0 um
voltage = 1.657 V
Beam dump: 1 nA
Colimator : 0.6 enA |
|
189
|
Thu Mar 9 16:54:27 2023 |
MK | Runs | | General | |
run control = 51
run data = /onlineNEDA_00/xData/hil099/run_0051_09-03-2023_16h25m16s/needleRU_i51_0051_0002.caendat
RU = 6.43MB/s
LF = 3.49 MB/s
plunger:
plunger run = 896
actual distance = 532.1 um
supposed distance = 532.7 um
micrometer = 532.9 um
position = 299.4 um
voltage = 1.659 V
Beam dump: 1 nA
Colimator : 0.6 enA |
|
188
|
Thu Mar 9 16:25:57 2023 |
IP | Runs | | General | run 50 stopped |
run 50 - stopped
-
- Run number: 50
- Start time: Thu Mar 9 00:50:57 2023
- Stop time: Thu Mar 9 16:22:37 2023
|
|
187
|
Thu Mar 9 15:17:32 2023 |
OST | Runs | | General | |
run control = 50
run data = /onlineNEDA_00/xData/hil099/run_0050_09-03-2023_00h50m28s/needleRU_i50_0050_0087.caendat
RU = 6.04 MB/s
LF = 3.34 MB/s
plunger:
plunger run = 879
actual distance = 532.2 um
supposed distance = 532.7 um
micrometer = 533.9 um
position = 299.5 um
voltage = 1.659 V
Beam dump: 1 nA
Colimator : 0.6 enA |
|
186
|
Thu Mar 9 13:37:33 2023 |
OST | Other | | Beam | Beam stopped 13:37-13:49 for control again. |
|
|
185
|
Thu Mar 9 13:22:37 2023 |
OST | Other | | Beam | beam stopped 13:21-13:24 for control |
|
|
184
|
Thu Mar 9 12:06:30 2023 |
OST | Runs | | General | |
run control = 50
run data = /onlineNEDA_00/xData/hil099/run_0050_09-03-2023_00h50m28s/needleRU_i50_0050_0070.caendat
RU = 6.89 MB/s
LF = 3.42 MB/s
plunger:
plunger run = 847
actual distance = 532.2 um
supposed distance = 532.7 um
micrometer = 533.6 um
position = 299.5 um
voltage = 1.659 V
Beam dump: 1 nA
Colimator : 0.5 enA |
|
183
|
Thu Mar 9 10:05:30 2023 |
OST | Runs | | General | |
run control = 50
run data = /onlineNEDA_00/xData/hil099/run_0050_09-03-2023_00h50m28s/needleRU_i50_0050_0058.caendat
RU = 7.48 MB/s
LF = 3.69 MB/s
plunger:
plunger run = 827
actual distance = 532.4 um
supposed distance = 532.7 um
micrometer = 533.7 um
position = 300.4 um
voltage = 1.658 V
Beam dump: 1 nA
Colimator : 0.5 enA |
|
182
|
Thu Mar 9 08:54:13 2023 |
OST | Runs | | General | |
run control = 50
run data =/onlineNEDA_00/xData/hil099/run_0050_09-03-2023_00h50m28s/needleRU_i50_0050_0051.caendat
RU = 6.86 MB/s
LF = 3.42 MB/s
plunger:
plunger run = 815
actual distance = 533.6 um
supposed distance = 532.7 um
micrometer = 533.3 um
position = 299.9 um
voltage = 1.658 V
Beam dump: 1 nA
Colimator : 0.5 enA |
|
181
|
Thu Mar 9 07:28:59 2023 |
WP | Runs | | General | General |
run control = 50
run data = /onlineNEDA_00/xData/hil099/run_0050_09-03-2023_00h50m28s/needleRU_i50_0050_0042.caendat
RU = 7.20 MB/s
LF = 3.54 MB/s
plunger:
plunger run = 801
actual distance = 533.2 um
supposed distance = 532.7 um
micrometer = 533.6 um
position = 300.7 um
voltage = 1.66 V
Beam dump: 1-1.5 enA (oscillating)
Colimator : 0.6 enA
|
|
180
|
Thu Mar 9 06:24:10 2023 |
WP | Runs | | General | General |
run control = 50
run data = /onlineNEDA_00/xData/hil099/run_0050_09-03-2023_00h50m28s/needleRU_i50_0050_0035.caendat
RU = 7.39 MB/s
LF = 3.60 MB/s
plunger:
plunger run = 790
actual distance = 532.8 um
supposed distance = 532.7 um
micrometer = 533.6 um
position = 300.1 um
voltage = 1.657 V
Beam dump: 1-1.5 enA (oscillating)
Colimator : 0.6 enA
|
|
179
|
Thu Mar 9 05:19:33 2023 |
WP | Runs | | General | General |
run control = 50
run data = /onlineNEDA_00/xData/hil099/run_0050_09-03-2023_00h50m28s/needleRU_i50_0050_0028.caendat
RU = 7.15 MB/s
LF = 3.68 MB/s
plunger:
plunger run = 779
actual distance = 533.1 um
supposed distance = 532.7 um
micrometer = 533.4 um
position = 299.6 um
voltage = 1.66 V
Beam dump: 1-1.5 enA (oscillating)
Colimator : 0.6 enA
|
|
178
|
Thu Mar 9 04:17:21 2023 |
WP | Runs | | General | General |
run control = 50
run data = /onlineNEDA_00/xData/hil099/run_0050_09-03-2023_00h50m28s/needleRU_i50_0050_0022.caendat
RU = 7.48 MB/s
LF = 3.59 MB/s
plunger:
plunger run = 769
actual distance = 531.1 um
supposed distance = 532.7 um
micrometer = 533.7 um
position = 300.5 um
voltage = 1.655 V
Beam dump: 1-1.5 enA (oscillating)
Colimator : 0.6 enA
|
|
177
|
Thu Mar 9 03:14:39 2023 |
WP | Runs | | General | General |
run control = 50
run data = /onlineNEDA_00/xData/hil099/run_0050_09-03-2023_00h50m28s/needleRU_i50_0050_0015.caendat
RU = 6.91 MB/s
LF = 3.48 MB/s
plunger:
plunger run = 758
actual distance = 533.5 um
supposed distance = 532.7 um
micrometer = 533.1 um
position = 300.9 um
voltage = 1.658 V
Beam dump: 1-1.5 enA (oscillating)
Colimator : 0.6 enA
|
|
176
|
Thu Mar 9 02:14:09 2023 |
WP | Runs | | General | General |
run control = 50
run data = /onlineNEDA_00/xData/hil099/run_0050_09-03-2023_00h50m28s/needleRU_i50_0050_0008.caendat
RU = 7.24 MB/s
LF = 3.64 MB/s
plunger:
plunger run = 748
actual distance = 532.1 um
supposed distance = 532.7 um
micrometer = 532.9 um
position = 299.4 um
voltage = 1.66 V
Beam dump: 1-1.5 enA (oscillating)
Colimator : 0.6 enA
|
|
175
|
Thu Mar 9 01:41:50 2023 |
GJ | Problem Fixed | | Hardware | TS zeroing - cables to S-IN from VME controller - between runs 49 and 50 |
Since we were observing jumps of 16 ns in timings of all channels of whole boards, the assumption was that the
signals from logical FIFO arrive at different times to S-IN inputs to zero the TS counters.
6 originally placed cables of quite the same length were replaced with 6 cables of declared 3-ns length, same
producer, borrowed from NW's equipment. |
|
174
|
Thu Mar 9 01:07:48 2023 |
WP | Runs | | General | New run started 50 (distance change) |
run control = 50
run data = /onlineNEDA_00/xData/hil099/run_0050_09-03-2023_00h50m28s/needleRU_i50_0050_0000.caendat
RU = 7.43MB/s
LF = 3.61 MB/s
plunger:
plunger run = 736
actual distance = 533 um
supposed distance = 532.7 um
micrometer = 533.5 um
position = 300 um
voltage = 1.657 V
Beam dump: 1-1.5 enA (oscillating)
Colimator : 0.6 enA
|
|
173
|
Wed Mar 8 22:36:30 2023 |
OST | Runs | | General | |
run control = 49
run data = /onlineNEDA_00/xData/hil099/run_0049_08-03-2023_09h31m08s/needleRU_i49_0049_0082.caendat
RU = 6.06 MB/s
LF = 3.44 MB/s
plunger:
plunger run = 709
actual distance = 382.9 um
supposed distance = 382.7 um
micrometer = 384.7 um
position = 150.2 um
voltage = 2.145 V
Beam dump: 1 nA
Colimator : 0.5 nA |
|
172
|
Wed Mar 8 20:46:16 2023 |
OST | Runs | | General | |
run control = 49
run data = /onlineNEDA_00/xData/hil099/run_0049_08-03-2023_09h31m08s/needleRU_i49_0049_0074.caendat
RU = 6.35 MB/s
LF = 3.47 MB/s
plunger:
plunger run = 693
actual distance = 382.5 um
supposed distance = 382.7 um
micrometer = 384.1 um
position = 149.8 um
voltage = 2.148 V
Beam dump: 1 nA
Colimator : 0.5 nA |
|
171
|
Wed Mar 8 19:01:49 2023 |
OST | Runs | | General | beam current was very low and beam increased after this entry |
run control = 49
run data = /onlineNEDA_00/xData/hil099/run_0049_08-03-2023_09h31m08s/needleRU_i49_0049_0064.caendat
RU = 5.75 MB/s
LF = 3.50 MB/s
plunger:
plunger run = 676
actual distance = 382.8 um
supposed distance = 382.7 um
micrometer = 384.9 um
position = 150.4 um
voltage = 2.146 V
Beam dump 0.7 |
|
170
|
Wed Mar 8 18:02:43 2023 |
BS | Runs | | General | Rates |
|
|
169
|
Wed Mar 8 17:59:38 2023 |
BS | Runs | | General | General |
run control = 49
run data = /onlineNEDA_00/xData/hil099/run_0049_08-03-2023_09h31m08s/needleRU_i49_0049_0058.caendat
RU = 9.83 MB/s
LF = 4.87 MB/s
plunger:
plunger run = 665
actual distance = 382.7 um
supposed distance = 382.7 um
micrometer = 384.4 um
position = 150.0 um
voltage = 2.148 V
Beam dump 1,25 ~ 1.5 nA |
|
168
|
Wed Mar 8 16:53:07 2023 |
BS | Runs | | General | Rates |
|
|
167
|
Wed Mar 8 16:51:13 2023 |
BS | Runs | | General | |
run control = 49
run data = /onlineNEDA_00/xData/hil099/run_0049_08-03-2023_09h31m08s/needleRU_i49_0049_0050.caendat
RU = 6.75 MB/s
LF = 3.44 MB/s
plunger:
plunger run = 654
actual distance = 382.7 um
supposed distance = 382.7 um
micrometer = 384.4 um
position = 150.0 um
voltage = 2.147 V
Beam dump 1 nA |
|
166
|
Wed Mar 8 15:57:53 2023 |
IK, AM | Problems | | General | Beam issue |
no beam in 15:52 - 16:21 due to power supply problem |
|
165
|
Wed Mar 8 14:47:34 2023 |
AM | Runs | | Beam | beam unstable |
two drops in beam intesitivity at 14:33, 14:37 and 14:51 |
|
164
|
Wed Mar 8 13:04:05 2023 |
IK | Runs | | General | Ge spectra |
Ge spectra after #161 - #162 beam tuning. |
|
163
|
Wed Mar 8 13:02:38 2023 |
IK | Runs | | General | Run 49 |
run control = 49
run data = /onlineNEDA_00/xData/hil099/run_0049_08-03-2023_09h31m08s/needleRU_i49_0049_0030.caendat
RU = 7.86 MB/s
LF = 3.87 MB/s
plunger:
plunger run = 616
actual distance = 382.7 um
supposed distance = 382.7 um
micrometer = 385.7 um
position = 150.0 um
voltage = 2.147 V
Beam dump 0.7 nA
|
|
162
|
Wed Mar 8 12:11:59 2023 |
IK | Problem Fixed | | General | beam tuned |
Beam tuning was made, focusing significantly improved.
Intensity:
beam dump: 0.9-1 nA,
collimator: 0.5 nA.
Rates:
RU = 8.2 MB/s
LF = 4.03 MB/s
EAGLE det4: 2.2 kHz
|
|
161
|
Wed Mar 8 11:42:14 2023 |
IK | Problems | | General | Run 49 |
Counting rates continued to increase (det4 > 3kHz). Beam current looked fine on the beam dump, but beam is fluctuating, and can reach 2nA on the collimator. Asked for improved focusing.
Attached screenshots and Ge spectra from before changing anything.
run control = 49
run data = /onlineNEDA_00/xData/hil099/run_0049_08-03-2023_09h31m08s/needleRU_i49_0049_0020.caendat
RU = 13.3 MB/s
LF = 6.15MB/s
plunger:
plunger run = 603
actual distance = 382.7 um
supposed distance = 382.7 um
micrometer = 385.9 um
position = 150.0 um
voltage = 2.146 V
Beam dump 0.7 nA
Collimator ~1.5-2nA when the generator retunes itself (prob the beam gets defocused at those moments)
|
|
160
|
Wed Mar 8 10:31:10 2023 |
IK | Runs | | General | Run 49 |
run control = 49
run data = /onlineNEDA_00/xData/hil099/run_0049_08-03-2023_09h31m08s/needleRU_i49_0049_0008.caendat
RU = 10.6 MB/s
LF = 4.89MB/s
plunger:
plunger run = 591
actual distance = 383.0 um
supposed distance = 382.7 um
micrometer = 385.8 um
position = 150.3 um
voltage = 2.145 V
Beam dump 0.7 nA
|
|
159
|
Wed Mar 8 10:27:26 2023 |
IK, BS | Other | | General | Ge spectra |
Count rates are still a bit high (~2.6kHz for EAGLE det4). Ge spectra looks fine compared to earlier ones.
|
|
158
|
Wed Mar 8 09:31:43 2023 |
IK | Runs | | General | Run 48 stopped, run 49 started |
Run 48 stopped at 9:29 to start a new run.
Run 49 is started okay at 9:31.
run control = 49
run data = /onlineNEDA_00/xData/hil099/run_0048_08-03-2023_01h08m57s/needleRU_i48_0048_0041.caendat
RU = 10.1 MB/s
LF = 4.68MB/s
plunger:
plunger run = 582
actual distance = 383.1 um
supposed distance = 382.7 um
micrometer = 385.8 um
position = 150.5 um
voltage = 2.145 V
Beam dump 0.7 nA
|
|
157
|
Wed Mar 8 07:57:05 2023 |
IK | Problems | | Beam | beam unstable |
The beam was unstable from 7:55. Stabilized around 8:03.
Counting rates are higher, EAGLE det4 went to ~2.5kHZ from ~2kHz (attached).
According to the operator, a bit of a tuning was done, current is 1nA.
run control = 48
run data = /onlineNEDA_00/xData/hil099/run_0048_08-03-2023_01h08m57s/needleRU_i48_0048_0041.caendat
RU = 10.4 MB/s
LF = 4.3 MB/s
|
|
156
|
Wed Mar 8 07:30:15 2023 |
KS, KSz | Problems | | Beam | beam unstable |
The beam was unstable from 7:18 to 7:25. |
|
155
|
Wed Mar 8 06:25:53 2023 |
KS, KSz | Runs | | General | |
run control = 48
run data = /onlineNEDA_00/xData/hil099/run_0048_08-03-2023_01h08m57s/needleRU_i48_0048_0029.caendat
RU = 6.59 MB/s
LF = 3.35 MB/s
plunger:
plunger run = 550
actual distance = 382,5 um
supposed distance = 382.7 um
micrometer = 384.6 um
position = 149.8um
voltage = 2.146 V
Beam dump = 1.5 nA
Collimater= 0.7 nA (?) |
|
154
|
Wed Mar 8 04:24:40 2023 |
KS, KSz | Runs | | General | Run 48 |
run control = 48
run data = /onlineNEDA_00/xData/hil099/run_0048_08-03-2023_01h08m57s/needleRU_i48_0048_0017.caendat
RU = 5.75 MB/s
LF = 3.21 MB/s
plunger:
plunger run = 530
actual distance = 382,7 um
supposed distance = 382.7 um
micrometer = 384.3 um
position = 150.3 um
voltage = 2.146 V
Beam dump = 1.5 nA
Collimater= 0.7 nA (?) |
|
153
|
Wed Mar 8 02:45:53 2023 |
KS, KSz | Other | | Beam | increase in Counting Rates |
Since 2:32 increased counting rate observed:
Sinde 3:45 decrease to 1.5 kHz ch4.
run control = 48
/onlineNEDA_00/xData/hil099/run_0048_08-03-2023_01h08m57s/needleRU_i48_0048_0007.caendat
run data =
RU = 8.69 MB/s
LF = 3.79 MB/s
Eagle Rated ch4: around 2.3 kHz
plunger: (2:48)
plunger run = 514
actual distance = 382.7 um
supposed distance = 382.7 um
micrometer = 383.5 um
position = 149.8 um
voltage = 2.144 V
Beam dump = 1.5 nA
Collimater= 0.5 nA |
|
152
|
Wed Mar 8 01:24:58 2023 |
KS, KSz | Runs | | General | New run started 48 (new distance) |
run control = 48
run data = /onlineNEDA_00/xData/hil099/run_0048_08-03-2023_01h08m57s/needleRU_i48_0048_0000.caendat
RU = 5.09 MB/s
LF = 3.15 MB/s
plunger:
plunger run = 498
actual distance = 382.7 um
supposed distance = 382.7 um
micrometer = 383.4 um
position = 149.7 um
voltage = 2.146 V
Beam dump = 0.7 nA
Collimater= 0.5 nA |
|
151
|
Wed Mar 8 01:24:04 2023 |
BS | Runs | | General | Run 47 Stopped to Change Distance Change |
Run 47 stopped and distance changed from 50 um (+ 100 um offset) to 150 um (+ 100 um offset)
Last plunger run for 50 um (+ 100 um offset) is 495 |
|
149
|
Wed Mar 8 00:31:05 2023 |
KS, KSz | Runs | | General | Run 47 standard info |
run control = 47
run data = /onlineNEDA_00/xData/hil099/run_0047_07-03-2023_23h42m03s/needleRU_i47_0047_0003.caendat
RU = 5.12 MB/s
LF = 3.32 MB/s
plunger:
plunger run = 491
actual distance = 282.9 um
supposed distance = 282.7 um
micrometer = 285.12 um
position = 50.2 um
voltage = 2.963 V
Beam dump = 0.7 nA
Collimater= 0.5 nA |
|
148
|
Tue Mar 7 23:54:05 2023 |
IP, KS | Runs | | General | |
run control = 47
run data = /onlineNEDA_00/xData/hil099/run_0047_07-03-2023_23h42m03s/needleRU_i47_0047_0000.caendat
RU = 4.47 MB/s
LF = 3.26 MB/s
plunger:
plunger run = 484
actual distance = 282.8 um
supposed distance = 282.7 um
micrometer = 285.2 um
position = 50.1 um
voltage = 2.965 V
Beam dump = 0.7 nA
Collimater= 0.5 nA |
|
147
|
Tue Mar 7 23:39:52 2023 |
IP, KS | Runs | | General | run 46 stopped |
Run 46 - stopped
- Run number: 46
- Start time: Tue Mar 7 15:09:06 2023
- Stop time: Tue Mar 7 23:38:07 2023
|
|
146
|
Tue Mar 7 21:55:45 2023 |
IP | Runs | | General | |
run control = 46
run data = /onlineNEDA_00/xData/hil099/run_0046_07-03-2023_15h08m38s/needleRU_i46_0046_0034.caendat
RU = 4.78 MB/s
LF = 3.10 MB/s
plunger:
plunger run = 464
actual distance = 282.8 um
supposed distance = 282.7 um
micrometer = 285.1 um
position = 49.9 um
voltage = 2.965 V
Beam dump = 0.7 nA
Collimater= 0.5 nA |
|
145
|
Tue Mar 7 20:45:13 2023 |
IP | Runs | | General | |
run control = 46
run data =/onlineNEDA_00/xData/hil099/run_0046_07-03-2023_15h08m38s/needleRU_i46_0046_0028.caendat
RU = 4.9 MB/s
LF = 3.14 MB/s
plunger:
plunger run = 452
actual distance = 282.4 um
supposed distance = 282.7 um
micrometer = 284.7 um
position = 49.7 um
voltage = 2.971 V
Beam dump = 0.7 nA
Collimater= 0.5 nA |
|
144
|
Tue Mar 7 20:42:03 2023 |
IP | Problems | | Beam | beam unstable |
There was a problem with the beam from 20:19 to 20:30.
Now it is fine. |
|
143
|
Tue Mar 7 19:24:25 2023 |
IP | Runs | | General | |
run control = 46
run data = /onlineNEDA_00/xData/hil099/run_0046_07-03-2023_15h08m38s/needleRU_i46_0046_0022.caendat
RU = 6.22 MB/s
LF = 3.34 MB/s
plunger:
plunger run = 439
actual distance = 282.5um
supposed distance = 282.7 um
micrometer = 284.9 um
position = 49.8 um
voltage = 2.97 V
Beam dump = 0.7 nA
Collimater= 0.5 nA |
|
142
|
Tue Mar 7 17:45:18 2023 |
IP | Runs | | General | |
run control = 46
run data = /onlineNEDA_00/xData/hil099/run_0046_07-03-2023_15h08m38s/needleRU_i46_0046_0013.caendat
RU = 6.10 MB/s
LF = 3.26 MB/s
plunger:
plunger run = 422
actual distance = 282.6um
supposed distance = 282.7 um
micrometer = 284.9 um
position = 49.9 um
voltage = 2.968 V
Beam dump = 0.7 nA
Collimater= 0.5 nA |
|
141
|
Tue Mar 7 16:06:16 2023 |
OST | Runs | | General | |
run control = 46
run data =/onlineNEDA_00/xData/hil099/run_0046_07-03-2023_15h08m38s/needleRU_i46_0046_0004.caendat
RU = 6.51 MB/s
LF = 3.44 MB/s
plunger:
plunger run = 405
actual distance = 283 um
supposed distance = 282.7 um
micrometer = 285.9 um
position = 50 um
voltage = 2.966 V
Beam dump = 0.7 nA
Collimater= 0.5 nA |
|
140
|
Tue Mar 7 15:14:29 2023 |
OST | Problem Fixed | | Software | Run 46 started-15_Ge and number 5 anticompton working now. |
VME crate with CAEN digitizers was rebooted.
Run 46 started, number 15_Ge and number 5 anticompton dedector working now.
|
|
139
|
Tue Mar 7 15:12:06 2023 |
OST | Problems | | Software | run 45 stopped |
14:30 pm to 15:00 run 45 crashed and stopped |
|
138
|
Tue Mar 7 14:39:08 2023 |
BS | Other | | General | Runlist File ScreenShot Accesses on 07 MArch at 14:38 |
|
|
137
|
Tue Mar 7 14:23:43 2023 |
BS | Other | | General | RU and BU Rates |
|
|
136
|
Tue Mar 7 14:07:33 2023 |
BS | Other | | General | Run Files Number |
/onlineNEDA_00/xData/hil099/run_0045_07-03-2023_09h14m17s/needleRU_i45_0045_0027.caendat
/onlineNEDA_00/xData/hil099/run_0045_07-03-2023_09h14m17s/needleLF_i44_0045_0010.adf |
|
135
|
Tue Mar 7 14:03:20 2023 |
BS | Runs | | General | Counting Rates |
|
|
134
|
Tue Mar 7 13:51:17 2023 |
OST | Runs | | General | |
run control = 45
not fixed number 15_Ge dedector and number 5 anticompton.
run data =/onlineNEDA_00/xData/hil099/run_0045_07-03-2023_09h14m17s/needleRU_i45_0045_0025.caendat
RU = 6.54 MB/s
LF = 3.60 MB/s
plunger:
plunger run = 384
actual distance = 283 um
supposed distance = 282.7 um
micrometer = 285.2 um
position = 50.3 um
voltage = 2.963 V
Beam dump = 1 nA
Collimater= 0.5 nA |
|
133
|
Tue Mar 7 12:50:52 2023 |
OST | Runs | | General | |
run control = 45
not fixed number 15_Ge dedector and number 5 anticompton.
run data =/onlineNEDA_00/xData/hil099/run_0045_07-03-2023_09h14m17s/needleRU_i45_0045_0019.caendat
RU = 6.42 MB/s
LF = 3.65 MB/s
plunger:
plunger run = 373
actual distance = 283 um
supposed distance = 282.7 um
micrometer = 285.2 um
position = 50.3 um
voltage = 2.962 V
Beam dump = 1 nA
Collimater= 0.5 nA |
|
132
|
Tue Mar 7 11:19:54 2023 |
OST | Runs | | General | |
run control = 45
not fixed number 15_Ge dedector and number 5 anticompton.
run data =/onlineNEDA_00/xData/hil099/run_0045_07-03-2023_09h14m17s/needleRU_i45_0045_0011.caendat
RU = 6.52 MB/s
LF = 3.57 MB/s
plunger:
plunger run = 358
actual distance = 282.8 um
supposed distance = 282.7 um
micrometer = 285.3 um
position = 50.1 um
voltage = 2.965 V
Beam dump = 1 nA
Collimater= 0.5 nA |
|
131
|
Tue Mar 7 09:56:07 2023 |
OST | Problems | | mechanics | Beam stopped and operators controlling number 15_Ge dedector. |
|
|
130
|
Tue Mar 7 09:41:44 2023 |
OST | Problems | | Software | number_Ge_15 dedector not taking data |
after run 45 I reset all spectrums and number_Ge_15 dedector not taking data.
i check the fans_monitor_scaler (EAGLE_array_monitor) monitor and number 15 Ge, number ACS 5 never change the color just staying white there is a problem.
|
|
129
|
Tue Mar 7 09:24:53 2023 |
OST | Runs | | General | |
run control = 45
run data =/onlineNEDA_00/xData/hil099/run_0045_07-03-2023_09h14m17s/needleRU_i45_0045_0000.caendat
RU = 6.92 MB/s
LF = 3.71 MB/s
plunger:
plunger run = 340
actual distance = 282.7 um
supposed distance = 282.7 um
micrometer = 285.5 um
position = 50.1 um
voltage = 2.967 V
Beam dump = 1 nA
Collimater= 0.5 nA |
|
128
|
Tue Mar 7 09:20:53 2023 |
OST | Problem Fixed | | Beam | run 45 start-local filter turn green |
I started run 45, and local filter turn green everything is ok. |
|
127
|
Tue Mar 7 09:18:01 2023 |
OST | Problems | | Beam | run number 44 crashed and local filter turned red-but data saved |
9:08 local filter turned red. Both .caendat and LF .adf files still incrementing. Stopped run 44, started run 45, looks OK.
|
|
126
|
Tue Mar 7 07:21:04 2023 |
JD, DW | Runs | | General | |
run control = 44
run data =/onlineNEDA_00/xData/hil099/run_0044_07-03-2023_03h15m45s/needleRU_i44_0044_0023.caendat
RU = 6.57 MB/s
LF = 3.45 MB/s
plunger:
plunger run = 318
actual distance = 282.6 um
supposed distance = 282.7 um
micrometer = 285.1 um
position = 50.0 um
voltage = 2.967 V
Beam dump = 1 nA
Collimater= 0.5 nA |
|
125
|
Tue Mar 7 06:18:46 2023 |
JD, DW | Runs | | General | |
run control = 44
run data =/onlineNEDA_00/xData/hil099/run_0044_07-03-2023_03h15m45s/needleRU_i44_0044_0017.caendat
RU =6.95 MB/s
LF = 3.54MB/s
plunger:
plunger run = 308
actual distance = 282.6 um
supposed distance = 282.7 um
micrometer = 285.1 um
position = 49.9 um
voltage = 2.968 V
Beam dump = 0.7-1 nA
Collimater= 0.5 nA |
|
124
|
Tue Mar 7 05:19:55 2023 |
JD, DW | Runs | | General | |
run control = 44
run data =/onlineNEDA_00/xData/hil099/run_0044_07-03-2023_03h15m45s/needleRU_i44_0044_0011.caendat
RU = 6.48 MB/s
LF = 3.42 MB/s
plunger:
plunger run = 298
actual distance = 282.7 um
supposed distance = 282.7 um
micrometer = 285.0 um
position = 50.1 um
voltage = 2.967 V
Beam dump = 0.7-1 nA
Collimater= 0.5 nA |
|
123
|
Tue Mar 7 04:16:28 2023 |
JD, DW | Runs | | General | |
run control = 44
run data =/onlineNEDA_00/xData/hil099/run_0044_07-03-2023_03h15m45s/needleRU_i44_0044_0005.caendat
RU = 6.49 MB/s
LF = 3.42 MB/s
plunger:
plunger run = 288
actual distance = 282.6um
supposed distance = 282.7um
micrometer = 285.1um
position = 49.9 um
voltage = 2.967V
Beam dump = 0.7-1nA
Collimater= 0.5nA
ELOG V3.0.0-21dc563 |
|
122
|
Tue Mar 7 03:26:54 2023 |
JD, DW | Runs | | General | Run 44 started |
run control = 44
run data =/onlineNEDA_00/xData/hil099/run_0044_07-03-2023_03h15m45s/needleRU_i44_0044_0000.caendat
RU = 6.46 MB/s
LF = 3.39 MB/s
plunger:
plunger run = 279
actual distance = 282.7 um
supposed distance = 282.7 um
micrometer = 285.1 um
position = 49.9 um
voltage = 2.966 V
Beam dump = 0.7-1 nA
Collimater= 0.5 nA |
|
121
|
Tue Mar 7 03:21:33 2023 |
JD, DW | Problem Fixed | | General | daq crash |
daq crashed at 02:59:00, resolved at 03:16:00
|
|
120
|
Tue Mar 7 02:02:18 2023 |
JD, DW | Runs | | General | |
run control = 43
run data = /onlineNEDA_00/xData/hil099/run_0043_07-03-2023_00h50m41s/needleRU_i43_0043_0006.caendat
RU = 6.27 MB/s
LF = 3.41 MB/s
plunger:
plunger run = 265
actual distance = 282.9 um
supposed distance = 282.7um
micrometer = 285.2 um
position = 50.2 um
voltage = 2.963V
Beam dump = 1 nA
Collimater= 0.5 nA
|
|
119
|
Tue Mar 7 00:54:40 2023 |
JD, DW | Runs | | General | New run started 43 |
run control = 43
run data = /onlineNEDA_00/xData/hil099/run_0043_07-03-2023_00h50m41s/needleRU_i43_0043_0000.caendat
RU = 7.13 MB/s
LF = 3.7 MB/s
plunger:
plunger run = 254
actual distance = 282.7 um
supposed distance = 282.7 um
micrometer = 285.2 um
position = 50 um
voltage = 2.966 V
Beam dump = 1 nA
Collimater= 0.5 nA
|
|
118
|
Tue Mar 7 00:10:02 2023 |
JD, DW | Runs | | General | |
RUN CONTROL = 42
Data = /onlineNEDA_00/xData/hil099/run_0042_06-03-2023_09h54m24s/needleRU_i42_0042_0075.caendat
RU = 6.86 MB/s
LF = 3.6 MB/s
Plunger ;
Plunger run = 246
Supposed Dist= 242.7 um
Micrometer = 245.8 um
Position = 10.3 um
Actual distance = 243.1 um
Voltage = 3.801 V
Beam dump = 1 nA
Collimater= 0.5 nA |
|
117
|
Mon Mar 6 22:30:46 2023 |
IK | Runs | | General | |
RUN CONTROL = 42
Data =/onlineNEDA_00/xData/hil099/run_0042_06-03-2023_09h54m24s/needleRU_i42_0042_0065.caendat
RU = 6.64 MB/s
LF = 3.54 MB/s
Plunger ;
Plunger run = 230
Supposed Dist= 242.7 um
Micrometer = 246 um
Position = 9.7 um
Actual distance = 243.1 um
Voltage = 4.184 V
Beam dump = 1enA |
|
116
|
Mon Mar 6 20:29:45 2023 |
IK | Runs | | General | |
RUN CONTROL = 42
Data =/onlineNEDA_00/xData/hil099/run_0042_06-03-2023_09h54m24s/needleRU_i42_0042_0053.caendat
RU = 6.75 MB/s
LF = 3.54 MB/s
Plunger ;
Plunger run = 210
Supposed Dist= 242.7 um
Micrometer = 245.2 um
Position = 9.6 um
Actual distance = 242.3 um
Voltage = 4.184 V |
|
115
|
Mon Mar 6 19:08:51 2023 |
IK | Runs | | General | |
RUN CONTROL = 42
Data =/onlineNEDA_00/xData/hil099/run_0042_06-03-2023_09h54m24s/needleRU_i42_0042_0045.caendat
RU = 6.95 MB/s
LF = 3.61 MB/s
Plunger ;
Plunger run = 196
Supposed Dist= 242.7 um
Micrometer = 245.2 um
Position = 9.7 um
Actual distance = 245.2 um
Voltage = 3.821 V
Beam dump = 1enA
|
|
114
|
Mon Mar 6 17:27:42 2023 |
OST | Runs | | General | |
RUN CONTROL = 42
Data =/onlineNEDA_00/xData/hil099/run_0042_06-03-2023_09h54m24s/needleRU_i42_0042_0035.caendat
RU = 5.43 MB/s
LF = 3.10 MB/s
Plunger ;
Plunger run = 179
Supposed Dist= 242.7 um
Micrometer = 245 um
Position = 9.7 um
Actual distance = 242.4 um
Voltage = 3.822 V
Beam dumb = 1 nA
Collimater=0.5 nA |
|
113
|
Mon Mar 6 17:19:24 2023 |
OST | Problems | | Beam | beam unstable and a little high |
16:30 beam increased 5 mb/s to 9 mb/s and stayed 1 hour 9 mb/s
17:10 beam fixed. stable |
|
112
|
Mon Mar 6 15:48:23 2023 |
OST | Runs | | General | |
RUN CONTROL = 42
Data =/onlineNEDA_00/xData/hil099/run_0042_06-03-2023_09h54m24s/needleRU_i42_0042_0026.caendat
RU = 5.24 MB/s
LF = 3.19 MB/s
Plunger ;
Plunger run = 162
Supposed Dist= 242.7 um
Micrometer = 245.5 um
Position = 10 um
Actual distance = 242.7 um
Voltage = 3.813 V
Beam dumb = 1 nA
Collimater=1 nA |
|
111
|
Mon Mar 6 14:01:48 2023 |
OST | Runs | | General | |
RUN CONTROL = 42
Data =/onlineNEDA_00/xData/hil099/run_0042_06-03-2023_09h54m24s/needleRU_i42_0042_0019.caendat
RU = 5.12 MB/s
LF = 3.20 MB/s
Plunger ;
Plunger run = 145
Supposed Dist= 242.7 um
Micrometer = 245.5 um
Position = 10 um
Actual distance = 242.7 um
Voltage = 3.812 V
Beam dumb = 1.5 nA
Collimater=1.25 nA |
|
110
|
Mon Mar 6 12:10:49 2023 |
OST | Runs | | General | |
RUN CONTROL = 42
Data = /onlineNEDA_00/xData/hil099/run_0042_06-03-2023_09h54m24s/needleRU_i42_0042_0010.caendat
RU = 5.46 MB/s
LF = 3.20 MB/s
Plunger ;
Plunger run = 127
Supposed Dist= 242.7 um
Micrometer = 245.9 um
Position = 10.4 um
Actual distance = 243 um
Voltage = 3.8 V
Beam dumb = 1.5 nA
Collimater=1.25 nA |
|
109
|
Mon Mar 6 10:56:46 2023 |
OST | Runs | | General | |
RUN CONTROL = 42
Data =/onlineNEDA_00/xData/hil099/run_0042_06-03-2023_09h54m24s/needleRU_i42_0042_0004.caendat
RU = 5.69 MB/s
LF = 3.37 MB/s
Plunger ;
Plunger run = 115
Supposed Dist= 242.7 um
Micrometer = 246.4 um
Position = 10.3 um
Actual distance = 243 um
Voltage = 3.801 V
Beam dumb = 1.5 nA |
|
108
|
Mon Mar 6 10:02:47 2023 |
OST | Problem Fixed | | General | New run started 42 |
RUN CONTROL = 42
Data =/onlineNEDA_00/xData/hil099/run_0042_06-03-2023_09h54m24s/needleRU_i42_0042_0000.caendat
/onlineNEDA_00/xData/hil099/run_0042_06-03-2023_09h54m24s/needleLF_i41_0042_0000.adf
RU = 6.01 MB/s
LF = 3.32 MB/s
Plunger ;
Plunger run = 105
Supposed Dist= 242.7 um
Micrometer = 246.1 um
Position = 9.9 um
Actual distance = 242.6 um
Voltage = 3.809 V
Beam dumb = 1.5 nA |
|
107
|
Mon Mar 6 09:53:06 2023 |
OST | Problems | | Beam | Beam dump decreased 2.5 nA to 1.5 nA- stopped run 41 |
9:20 to 9:50 am beam current stayed 2.5 nA . After 9:50 am decrease 1.5 nA |
|
106
|
Mon Mar 6 09:19:41 2023 |
OST | Runs | | General | |
RUN CONTROL = 41
Data =/onlineNEDA_00/xData/hil099/run_0041_06-03-2023_00h58m13s/needleRU_i41_0041_0050.caendat
RU = 8.13 MB/s
LF = 4.21 MB/s
Plunger ;
Plunger run = 98
Supposed Dist= 242.7 um
Micrometer = 245.8 um
Position = 9.7 um
Actual distance = 242.4 um
Voltage = 3.821 V
Beam dumb = 2 nA
Collimeter = 2 nA |
|
105
|
Mon Mar 6 08:10:32 2023 |
JD | Runs | | General | |
RUN CONTROL = 41
Data = /onlineNEDA_00/xData/hil099/run_0041_06-03-2023_00h58m13s/needleRU_i41_0041_0043.caendat
RU = 7.3 MB/s
LF = 3.65 MB/s
Plunger ;
Plunger run = 86
Supposed Dist= 242.7 um
Micrometer = 245.3 um
Position = 9.7 um
Actual distance = 242.4 um
Voltage = 3.821 V
Beam dumb = 1.25 nA
Collimeter = 0.75 nA |
|
104
|
Mon Mar 6 07:19:01 2023 |
JD, DW | Runs | | General | |
RUN CONTROL = 41
Data = /onlineNEDA_00/xData/hil099/run_0041_06-03-2023_00h58m13s/needleRU_i41_0041_0038.caendat
RU = 6.46 MB/s
LF = 3.53 MB/s
Plunger ;
Plunger run = 78
Supposed Dist= 242.7 um
Micrometer = 245.5 um
Position = 10.0 um
Actual distance = 242.7 um
Voltage = 3.808 V
Beam dumb = 2.0 nA
Collimeter = 1.25 nA |
|
103
|
Mon Mar 6 06:11:51 2023 |
JD, DW | Runs | | General | |
RUN CONTROL = 41
Data = /onlineNEDA_00/xData/hil099/run_0041_06-03-2023_00h58m13s/needleRU_i41_0041_0031.caendat
RU = 7.58 MB/s
LF = 3.76 MB/s
Plunger ;
Plunger run = 67
Supposed Dist= 242.7 um
Micrometer = 245.4 um
Position = 9.9 um
Actual distance =242.6 um
Voltage = 3.814 V
Beam dumb = 2.5 nA
Collimeter = 1 nA |
|
102
|
Mon Mar 6 05:21:16 2023 |
JD DW | Runs | | General | |
RUN CONTROL = 41
Data = /onlineNEDA_00/xData/hil099/run_0041_06-03-2023_00h58m13s/needleRU_i41_0041_0026.caendat
RU = 8.24 MB/s
LF = 3.96 MB/s
Plunger ;
Plunger run = 58
Supposed Dist= 242.7 um
Micrometer = 245.0um
Position = 9.9 um
Actual distance =242.5 um
Voltage = 3.816V
Beam dumb = 2.5 nA
Collimeter = 1.1 nA |
|
101
|
Mon Mar 6 05:16:46 2023 |
JD, DW | Problem Fixed | | Beam | |
Beam back on 05:15 |
|
100
|
Mon Mar 6 05:15:43 2023 |
JD, DW | Problems | | Beam | No beam 05:10:00 |
No beam 05:10:00 |
|
99
|
Mon Mar 6 04:17:48 2023 |
JD, DW | Runs | | General | |
RUN CONTROL = 41
Data = /onlineNEDA_00/xData/hil099/run_0041_06-03-2023_00h58m13s/needleRU_i41_0041_0020.caendat
RU = 7.26 MB/s
LF = 3.72 MB/s
Plunger ;
Plunger run = 47
Supposed Dist= 242.7 um
Micrometer = 244.5 um
Position = 9.6 um
Actual distance = 242.3 um
Voltage = 3.826 V
Beam dumb = 2.5 nA
Collimeter = 0.8 nA |
|
98
|
Mon Mar 6 03:17:48 2023 |
JD, DW | Runs | | General | |
RUN CONTROL = 41
Data = /onlineNEDA_00/xData/hil099/run_0041_06-03-2023_00h58m13s/needleRU_i41_0041_0014.caendat
RU = 6.94 MB/s
LF = 3.62 MB/s
Plunger ;
Planger run = 38
Supposed Dist= 242.7um
Micrometer = 244.2 um
Position = 9.6 um
Actual distance = 242.4 um
Voltage = 3.822 V
Beam dumb = 2.5 nA
Collimeter = 0.85 nA |
|
97
|
Mon Mar 6 02:13:32 2023 |
JD, DW | Runs | | General | |
RUN CONTROL = 41
Data = /onlineNEDA_00/xData/hil099/run_0041_06-03-2023_00h58m13s/needleRU_i41_0041_0007.caendat
RU = 7.55 MB/s
LF = 3.79 MB/s
Plunger ;
Planger run = 27
Supposed Dist= 242.7 um
Micrometer = 243.6 um
Position = 9.6 um
Actual distance = 242.3 um
Voltage = 3.825 V
Beam dumb = 2.5 nA
Collimeter = 0.9 nA |
|
96
|
Mon Mar 6 01:10:59 2023 |
JD, DW | Runs | | General | |
RUN CONTROL = 41
Data = /onlineNEDA_00/xData/hil099/run_0041_06-03-2023_00h58m13s/needleRU_i41_0041_0000.caendat
RU = 6.23 MB/s
LF = 3.55 MB/s
Plunger ;
Planger run = 16
Supposed Dist= 242.7 um
Micrometer = 242.7um
Position = 9.7 um
Actual distance = 242.4um
Voltage = 3.824V
Beam dumb = 2.75 nA
Collimeter = 0.8 nA |
|
95
|
Mon Mar 6 01:01:26 2023 |
BS | Runs | | General | Run 41 started |
Run 41 started
Plunger distance 10 um |
|
94
|
Mon Mar 6 01:00:29 2023 |
BS | Runs | | General | Run 40 stooped |
Run 40 stooped |
|
93
|
Mon Mar 6 00:43:27 2023 |
BS, GJ | Runs | | General | Run 40 Started |
Before this run TSs were moved on the LF level, so the BU has easier job to do and everything is more stable.
BU gate was changed from 1500 to 500 ns, this stay valid from now on.
Run 40 Started.
New target
Offset 100 um
RUN CONTROL = 40
Data = /onlineNEDA_00/xData/hil099/run_0040_06-03-2023_00h38m10s/needleRU_i40_0040_0000.caendat
RU = 7.21 MB/s
LF = 3.55 MB/s
Plunger ;
Planger run = 8
0-Point = 232, 7 um
Supposed Distance = 234,7 um
Micrometer = 187.5 um
Position = 241.1 um
Actual Distance = 234,5 um
Voltage =4,106V
Beam dumb =
Collimeter = |
|
92
|
Mon Mar 6 00:30:32 2023 |
MP, ANJ | Other | | Target | new target mounted |
New target mounted.
106Cd 1 mg/cm2
181Ta 1.2 mg/cm2
Problems in alignment. Offset of 100 um, in spite of the fact that a gap is visible at this distance, and a hair could be moved in between stopper and the target.
Decided to close and pump anyway, after several attempts to improve the alignment.
Stopper same as before, slightly more stretched. |
|
91
|
Sun Mar 5 22:32:56 2023 |
MP | Other | | | change of the target |
See pictures in the attachment:
1) stopper seen from the back (upstream view)
2) stopper seen from the front (downstream view)
Mind the two small off-center dots. It is clear that the beam hits the edge of the frame. This is possible because the 5 mm collimator has two small dots outside the 5 mm hole (the collimator can be seen in the beam tube).
3) old target, upstream view
4) new target, upstream view, after the stopper drove into it
5) new target, before it was mounted
6) the stopper, after the collision with the target. One of the visible rings is probably due to this collision, other traces probably reflect its complicated history earlier.
|
|
90
|
Sun Mar 5 16:58:45 2023 |
MP | Problems | | Other | run 37 crashed, run 38 junk |
Run 37 stopped by itslelf at 15:43. This was noticed at about 16:10 by observing that grafana data rates do not change.
Stop at Run COntrol. LF looks disabled.
Attempt to restart normal way --> run 38 --> failed
Attempts to load topology failed.
Cannot any more refresh or load the Run COntrol web page (192.168.0.133:5000)
Grzes is trying to fix the problem remotely, while we are starting changing of the target....
|
|
89
|
Sun Mar 5 15:07:24 2023 |
mgb | Runs | | General | Beam dump decreased 1.0 nA to 0.75 |
RUN CONTROL = 37
Data = /onlineNEDA_00/xData/hil099/run_0037_04-03-2023_22h56m17s/needleRU_i37_0037_0106.caendat
RU = 8.65 MB/s
LF = 4.11 MB/s
Plunger ;
Planger run = 745
Supposed Dist=240 um
Micrometer = 187.5 um
Position = 241.1 um
Actual distance = 240.6 um
Voltage = 2.715 V
Beam dumb = 0.75 nA
Collimeter =0.65 nA
|
|
88
|
Sun Mar 5 13:52:34 2023 |
OST | Runs | | General | |
RUN CONTROL = 37
Data = /onlineNEDA_00/xData/hil099/run_0037_04-03-2023_22h56m17s/needleRU_i37_0037_0097.caendat
RU = 8.17
LF = 4.04
Plunger ;
Planger run = 733
Supposed Dist=240
Micrometer = 187.6
Position = 241.3
Voltage = 2.715
Beam dumb = 1 nA
Collimeter =0.8 nA
Everything is stable |
|
87
|
Sun Mar 5 11:45:36 2023 |
OST | Runs | | General | |
RUN CONTROL = 37
Data =/onlineNEDA_00/xData/hil099/run_0037_04-03-2023_22h56m17s/needleRU_i37_0037_0082.caendat
RU = 8.50
LF = 4.14
Plunger ;
Planger run = 712
Supposed Dist=240
Micrometer = 187.6
Position = 241.3
Voltage = 2.714
Beam dumb = 1 nA
Collimeter =0.8 nA
Everything is stable. |
|
86
|
Sun Mar 5 10:17:03 2023 |
OST | Runs | | General | |
RUN CONTROL = 37
Data =/onlineNEDA_00/xData/hil099/run_0037_04-03-2023_22h56m17s/needleRU_i37_0037_0072.caendat
RU = 8.01
LF = 4.02
Plunger ;
Planger run = 698
Supposed Dist=240
Micrometer = 186.9
Position = 240.8
Voltage = 2.72
Beam dumb = 1 nA
Collimeter =0.7 nA
Everything is stable. |
|
85
|
Sun Mar 5 08:54:08 2023 |
OST | Runs | | General | |
RUN CONTROL = 37
Data = /onlineNEDA_00/xData/hil099/run_0037_04-03-2023_22h56m17s/needleRU_i37_0037_0061.caendat
RU = 8.12
LF = 3.94
Plunger ;
Planger run = 683
Supposed Dist=240
Micrometer = 186.4
Position = 239.9
Voltage = 2.724
Beam dumb = 1 nA
Collimeter =2.5 nA
Everything is stable. |
|
84
|
Sun Mar 5 07:12:49 2023 |
JD DW | Runs | | General | |
RUN CONTROL = 37
run data =/onlineNEDA_00/xData/hil099/run_0037_04-03-2023_22h56m17s/needleRU_i37_0037_0051.caendat
RU = 8.02 MB/s
LF = 3.97 MB/s
Plunger ;
Plunger run = 667
Supposed Dist= 240 um
Actual Distance = 238.8 um
micrometer = 186.0 um
Voltage = 2.723 V
Beam dumb = 1 nA
Collimeter = 0.75 nA |
|
83
|
Sun Mar 5 06:03:26 2023 |
JD DW | Runs | | General | |
UN CONTROL = 37
run data =/onlineNEDA_00/xData/hil099/run_0037_04-03-2023_22h56m17s/needleRU_i37_0037_0043.caendat
RU = 7.65 MB/s
LF = 3.86 MB/s
Plunger ;
Plunger run = 656
Supposed Dist= 240 um
Actual Distance = 239.3 um
micrometer = 186.1 um
Voltage = 2.725 V
Beam dumb = 1 nA
Collimeter = 0.75 nA |
|
82
|
Sun Mar 5 05:06:50 2023 |
JD DW | Runs | | General | |
RUN CONTROL = 37
run data =/onlineNEDA_00/xData/hil099/run_0037_04-03-2023_22h56m17s/needleRU_i37_0037_0037.caendat
RU = 7.93 MB/s
LF = 3.91 MB/s
Plunger ;
Plunger run = 646
Supposed Dist= 240 um
Actual Distance = 239.5 um
micrometer = 186.0um
Voltage = 2.725 V
Beam dumb = 1 nA
Collimeter = 1 nA |
|
81
|
Sun Mar 5 04:04:39 2023 |
JD DW | Runs | | General | |
UN CONTROL = 37
run data =/onlineNEDA_00/xData/hil099/run_0037_04-03-2023_22h56m17s/needleRU_i37_0037_0030.caendat
RU = 7.78 MB/s
LF = 3.85 MB/s
Plunger ;
Plunger run = 636
Supposed Dist= 240 um
Actual Distance = 239.0 um
micrometer = 185.8 um
Voltage = 2.724 V
Beam dumb = 1 nA
Collimeter = 1 nA |
|
80
|
Sun Mar 5 03:11:45 2023 |
JD DW | Runs | | General | |
RUN CONTROL = 37
run data =/onlineNEDA_00/xData/hil099/run_0037_04-03-2023_22h56m17s/needleRU_i37_0037_0023.caendat
RU = 7.62 MB/s
LF = 3.83 MB/s
Plunger ;
Plunger run = 626
Supposed Dist= 240 um
Actual Distance = 238.5 um
micrometer = 185.5 um
Voltage = 2.727 V
Beam dumb = 1 nA
Collimeter = 1 nA |
|
79
|
Sun Mar 5 02:06:40 2023 |
JD DW | Runs | | General | |
UN CONTROL = 37
run data =/onlineNEDA_00/xData/hil099/run_0037_04-03-2023_22h56m17s/needleRU_i37_0037_0017.caendat
RU = 7.86 MB/s
LF = 3.88 MB/s
Plunger ;
Planger run = 616
Supposed Dist= 240 um
Actual Distance = 239.8 um
micrometer = 185.9 um
Voltage = 2.721 V
Beam dumb = 0.75 nA
Collimeter = 0.5nA
ELOG V3.0.0-21dc563 |
|
78
|
Sun Mar 5 01:26:58 2023 |
JD DW | Runs | | General | |
UN CONTROL = 37
run data =/onlineNEDA_00/xData/hil099/run_0037_04-03-2023_22h56m17s/needleRU_i37_0037_0010.caendat
RU = 6.96 MB/s
LF = 3.65 MB/s
Plunger ;
Planger run = 607
Supposed Dist= 240 um
Actual Distance = 240.1 um
micrometer = 186.4 um
Voltage = 2.719 V
Beam dumb = 0.75 nA
Collimeter = 0.55nA |
|
77
|
Sun Mar 5 00:08:06 2023 |
AF | Runs | | General | |
AF
UN CONTROL = 37
Run Data =/onlineNEDA_00/xData/hil099/run_0037_04-03-2023_22h56m17s/needleRU_i37_0037_0005.caendat
RU = 5.38 MB/s
LF = 3.30 MB/s
Plunger ;
Planger run = 596
Supposed Dist=240 um
Actual Distance = 240 um
Position = 240.8 um
Voltage = 2.716 V
Beam dumb =
Collimeter =
|
|
76
|
Sat Mar 4 23:28:16 2023 |
AF | Runs | | General | |
AF
UN CONTROL = 37
Run Data =/onlineNEDA_00/xData/hil099/run_0037_04-03-2023_22h56m17s/needleRU_i37_0037_0000.caendat
RU = 5.91 MB/s
LF = 3.43 MB/s
Plunger ;
Planger run = 585
Supposed Dist=240 um
Actual Distance = 240 (+60) um
Position = 240.9 um
Voltage = 2.717 V
Beam dumb = 0.75 - 1.0 enA
Collimeter = 0.75-1.0 enA
|
|
75
|
Sat Mar 4 20:56:40 2023 |
AF | Runs | | General | |
AF
UN CONTROL = 36
Run Data =/onlineNEDA_00/xData/hil099/run_0036_03-03-2023_16h47m35s/needleRU_i36_0036_0154.caendat
RU = 5.91 MB/s
LF = 3.43 MB/s
Plunger ;
Planger run = 563
Supposed Dist=10 um
Actual Distance = 9.8 um
micrometer = 11.0 um
Position = 10.1 um
Voltage = 7.947 V
Beam dumb =
Collimeter =
Stopped at 10.51 pm
Plan: change the distance between the target and the stopper
Plunger run nr at stop: 582
beam current at stop: 0.9 enA at the beam dump
|
|
74
|
Sat Mar 4 19:14:30 2023 |
AF | Runs | | General | |
AF
UN CONTROL = 36
Run Data =/onlineNEDA_00/xData/hil099/run_0036_03-03-2023_16h47m35s/needleRU_i36_0036_0144.caendat
RU = 6.46 MB/s
LF = 3.48 MB/s
Plunger ;
Planger run = 546
Supposed Dist=10 um
Actual Distance = 10 um
micrometer = 11.4 um
Position = 10.4 um
Voltage = 7.923 V
Beam dumb = 1 nA
Collimeter =0.7 nA |
|
73
|
Sat Mar 4 18:02:48 2023 |
mgb | Runs | | General | |
UN CONTROL = 36
Run Data =/onlineNEDA_00/xData/hil099/run_0036_03-03-2023_16h47m35s/needleRU_i36_0036_0138.caendat
RU = 6.39 MB/s
LF = 3.42 MB/s
Plunger ;
Planger run = 534
Supposed Dist=10 um
Actual Distance = 9.9 um
micrometer = 11.4 um
Position = 10.3 um
Voltage = 7.933 V
Beam dumb = 1 nA
Collimeter =0.7 nA |
|
72
|
Sat Mar 4 17:09:13 2023 |
mgb | Runs | | General | |
RUN CONTROL = 36
Run Data = /onlineNEDA_00/xData/hil099/run_0036_03-03-2023_16h47m35s/needleRU_i36_0036_0133.caendat
RU = 6.45 MB/s
LF = 3.45 MB/s
Plunger ;
Planger run = 525
Supposed Dist=10 um
Actual Distance = 9.8 um
micrometer = 11.2 um
Position = 10.1 um
Voltage = 7.943 V
Beam dumb = 1 nA
Collimeter =0.7 nA |
|
71
|
Sat Mar 4 16:06:19 2023 |
mgb | Runs | | General | |
RUN CONTROL = 36
Run Data = /onlineNEDA_00/xData/hil099/run_0036_03-03-2023_16h47m35s/needleRU_i36_0036_0127.caendat
RU = 6.25
LF = 3.39
Plunger ;
Planger run = 515
Supposed Dist=10 um
Actual Distance = 9.7 um
Position = 10.3 um
Voltage = 7.938 V
Beam dumb = 1 nA
Collimeter =0.7 nA |
|
70
|
Sat Mar 4 15:02:54 2023 |
mgb | Runs | | General | running stable |
RUN CONTROL = 36
Run Data = /onlineNEDA_00/xData/hil099/run_0036_03-03-2023_16h47m35s/needleRU_i36_0036_0122.caendat
RU = 5.99
LF = 3.35
Plunger ;
Planger run = 504
Supposed Dist=10
Micrometer = 11.1
Position = 10.2
Voltage = 8.964
Beam dumb = 1 nA
Collimeter =0.7 nA |
|
69
|
Sat Mar 4 13:43:20 2023 |
OST | Runs | | General | |
RUN CONTROL = 36
Data =/onlineNEDA_00/xData/hil099/run_0036_03-03-2023_16h47m35s/needleRU_i36_0036_0114.caendat
RU = 7.30
LF = 3.70
Plunger ;
Planger run = 491
Supposed Dist=10
Micrometer = 10.9
Position = 10.4
Voltage = 7.924
Beam dumb = 1 nA
Collimeter =0.7 nA
Everythings continues to stable. |
|
68
|
Sat Mar 4 12:34:52 2023 |
OST | Runs | | General | |
RUN CONTROL = 36
Data =/onlineNEDA_00/xData/hil099/run_0036_03-03-2023_16h47m35s/needleRU_i36_0036_0107.caendat
RU = 6.17
LF = 3.25
Plunger ;
Planger run = 479
Supposed Dist=10
Micrometer = 10.6
Position = 10.5
Voltage = 7.908
Beam dumb = 0.8 nA
Collimeter =0.7 nA
Everythings continues to stable. |
|
67
|
Sat Mar 4 11:06:31 2023 |
OST | Runs | | General | |
RUN CONTROL = 36
Data =/onlineNEDA_00/xData/hil099/run_0036_03-03-2023_16h47m35s/needleRU_i36_0036_0100.caendat
RU = 6.03
LF = 3.36
Plunger ;
Planger run = 465
Supposed Dist=10
Micrometer = 10.5
Position = 10.5
Voltage = 7.91
Beam dumb = 0.75 nA
Collimeter =0.6 nA
Everythings is looking stable. |
|
66
|
Sat Mar 4 09:51:32 2023 |
OST | Runs | | General | |
RUN CONTROL = 36
Data =/onlineNEDA_00/xData/hil099/run_0036_03-03-2023_16h47m35s/needleRU_i36_0036_0094.caendat
RU = 6.43
LF = 3.45
Plunger ;
Planger run = 452
Supposed Dist=10
Micrometer = 10.4
Position = 10.4
Voltage = 7.926
Beam dumb = 1 nA
Collimeter =0.5 nA
Everythings is looking stable. |
|
65
|
Sat Mar 4 08:27:23 2023 |
OST | Runs | | General | |
RUN CONTROL = 36
Data =/onlineNEDA_00/xData/hil099/run_0036_03-03-2023_16h47m35s/needleRU_i36_0036_0087.caendat
RU = 4.57
LF = 3.11
Plunger ;
Planger run = 437
Supposed Dist=10
Micrometer = 10.1
Position = 10.4
Voltage = 7.923
Beam dumb = 0.75 nA
Collimeter =0.5 nA
Everythings is looking stable. |
|
64
|
Fri Mar 3 23:38:28 2023 |
SP | Runs | | General | How different Ge count |
All germanium detecors look reasonable, as attached. |
|
63
|
Fri Mar 3 20:50:31 2023 |
IK, MP, GJ | Other | | Data analysis | Ge spectra |
Ge rates increasing, similar to what it was 24h before. Asking to decrease beam intensity by a factor of 2.
Attached Ge spectra before decreasing.
Before decreas beam current was 1.75enA, afterwards 1.1enA. |
|
62
|
Fri Mar 3 19:41:27 2023 |
IK | Problems | | Hardware | Beamdump readout issue Vol.2. |
Issue described in #61 continues to persist.
Beam stopped from 19:20 to 19:32, run 36 ongoing; MP, GJ, BS entering the experimental hall.
They changed the position of the grounding point on the chamber, moving it downstream after a fitting/joining part (A to B on the attached picture [artist: GJ]).
|
|
61
|
Fri Mar 3 17:52:41 2023 |
IK | Problem Fixed | | Hardware | Beamdump readout issue - solved |
Current readout issues from beamdump. Beam stopped from 17:46-17:52, run 36 ongoing.
MP & GJ checking the grounding and connection the beamdump readout. No visible issue found in the exp hall, but copper grounding wire was tightened, which seemingly resolved the issue (stability of beamdump readout). |
|
60
|
Fri Mar 3 16:47:29 2023 |
IK | Runs | | General | Run 36 started |
Run 36 Started
New Beam energy is 150 MeV
The beam dumb currennt is 2.5 enA.
Plunger run = 282
|
|
59
|
Fri Mar 3 15:04:33 2023 |
KWL | Other | | General | run 35 stopped |
Run 35 stopped. An attempt to check if we can get 5 MeV higher beam energy. |
|
58
|
Fri Mar 3 14:22:12 2023 |
IP | Runs | | General | |
the beam comes back. The run 35 is still going.
plunger run # 257
Beam dump .... enA (given by operators) * 7 (following entry ID#39) = ... enA
Collimator .... enA
Run Data = /onlineNEDA_00/xData/hil099/run_0035_03-03-2023_00h04m26s/needleRU_i35_0035_0059.caendat
RU : 6.18 MB/s
LF : 8.44 MB/s
Supposed Distance = 10 um
position of the target = 10.2 um
micrometer = 8.8 um
Voltage = 7.94 V
|
|
57
|
Fri Mar 3 13:54:41 2023 |
IP. KWL | Runs | | General | beam energy measurement |
beam stop due to the beam energy measurement
The beam energy: ~145 MeV |
|
56
|
Fri Mar 3 13:43:56 2023 |
IP. KWL | Runs | | | 511 annihilation and 279 Au lines in Ge rings |
The counting rate in 511 keV line for sum of the Ge detectors placed at 101, 117 and 143 degrees (with approved ACS). The largest intensity is visible for Ge at 143 degrees, lowest for 101 deg.
=============================== RING 101
Integration in spectrum user_ge_ring101_acceptedACS_clone.spc
RESULT : 3895
=============================== RING 117
Integration in spectrum user_ge_ring117_acceptedACS.spc
RESULT : 9392
=============================== RING 143
Integration in spectrum user_ge_ring143_acceptedACS.spc
RESULT : 15767
The Coulex of 197Au (279.5 keV ) line is visible in all rings with a comparable intensity:
=============================== RING 101
Integration in spectrum user_ge_ring101_acceptedACS_clone.spc
RESULT : 12491
=============================== RING 117
Integration in spectrum user_ge_ring117_acceptedACS.spc
RESULT : 11443
===============================RING 143
Integration in spectrum user_ge_ring143_acceptedACS.spc
RESULT : 10460
|
|
55
|
Fri Mar 3 12:11:24 2023 |
IP | Runs | | General | |
the beam comes back. |
|
54
|
Fri Mar 3 11:48:29 2023 |
IP | Runs | | General | beam stopped |
The beam is gone. |
|
53
|
Fri Mar 3 11:37:25 2023 |
IP | Runs | | General | |
plunger run # 230
Beam dump 1.2 enA (given by operators) * 7 (following entry ID#39) = 8.4 enA
Collimator 0.6 enA
Run Data =/onlineNEDA_00/xData/hil099/run_0035_03-03-2023_00h04m26s/needleRU_i35_0035_0047.caendat
RU : 5.88 MB/s
LF : 8.35 MB/s
Supposed Distance = 10 um
position of the target = 10.2 um
micrometer = 8.8 um
Voltage = 7.94 V |
|
52
|
Fri Mar 3 10:21:18 2023 |
IP. KWL | Runs | | General | beam intensity back to 1.25 enA at the beam dump |
we increased beam intensity to 1.25 enA (readout at the beam dump) |
|
51
|
Fri Mar 3 10:09:20 2023 |
IP. KWL | Runs | | General | beam intensity decreased to 0.3 enA (at beam dump) on our request |
// we noticed yesterday that GE at 143 degrees counts more than those placed at 117 and 101. The 511 keV line (+ background) is much more pronounced for Ge at 143 degrees. To investigate this issue we decreased the beam intensity to 0.3 enA ( value given by operators at the beam dump ).
Conclusion - decrease of the beam intensity does not explain above observations (se attached figs)
plunger run # 216
Beam dump 0.3 enA (given by operators) * 7 (following entry ID#39) = 2.1 enA
Collimator enA
Run Data =/onlineNEDA_00/xData/hil099/run_0035_03-03-2023_00h04m26s/needleRU_i35_0035_0040.caendat
RU : 2.15 MB/s
LF : 5.60 MB/s
Supposed Distance = 10 um
position of the target = 10.6 um
micrometer = 8.8 um
Voltage = 7.8 V |
|
50
|
Fri Mar 3 09:30:15 2023 |
IP. KWL | Runs | | General | |
plunger run # 208
Beam dump 0.75 enA (given by operators) * 7 (following entry ID#39) = 5.25 enA
Collimator 0.75 enA
Run Data =/onlineNEDA_00/xData/hil099/run_0035_03-03-2023_00h04m26s/needleRU_i35_0035_0037.caendat
RU : 3.85 MB/s
LF : 7,29 MB/s
Supposed Distance = 10 um
position of the target = 10.2 um
micrometer = 9.3 um
Voltage = 7.93 V |
|
49
|
Fri Mar 3 08:20:13 2023 |
KWL | Runs | | General | |
plunger run # 196
Beam dump 1 enA (given by operators) * 7 (following entry ID#39) = 7 enA
Collimator 0.75 enA
Run Data =/onlineNEDA_00/xData/hil099/run_0035_03-03-2023_00h04m26s/needleRU_i35_0035_0033.caendat
RU : 4.10 MB/s
LF : 7.48 MB/s
Supposed Distance = 10 um
position of the target = 10.2 um
micrometer = 9 um
Voltage = 7.94 V |
|
48
|
Fri Mar 3 07:32:28 2023 |
OST | Runs | | General | |
plunger run # 188
Beam dump 2.5 enA
Collimator 0.8 enA
Run Data = /onlineNEDA_00/xData/hil099/run_0035_03-03-2023_00h04m26s/needleRU_i35_0035_0030.caendat
RU : 4.15 MB/s
LF : 7.69 MB/s
Supposed Distance = 10 um
position of the target = 10.2 um
micrometer = 9 um
Voltage = 8.964 V
Readout data decreased 5 mb/s to 4 mb/s during 6:30 to 7:30 am. slowly returning to normal value
|
|
47
|
Fri Mar 3 06:24:03 2023 |
OST | Runs | | General | |
plunger run # 178
Beam dump 2.5 enA
Collimator 0.9 enA
Run Data =/onlineNEDA_00/xData/hil099/run_0035_03-03-2023_00h04m26s/needleRU_i35_0035_0027.caendat
RU : 4.65 MB/s
LF : 7.52 MB/s
Supposed Distance = 10 um
position of the target = 10.1 um
micrometer = 8.7 um
Voltage = 7.97 V
nothing has changed. the situation is stable. |
|
46
|
Fri Mar 3 05:18:35 2023 |
OST | Runs | | General | |
plunger run # 167
Beam dump 2.5 enA
Collimator 1.0 enA
Run Data =/onlineNEDA_00/xData/hil099/run_0035_03-03-2023_00h04m26s/needleRU_i35_0035_0022.caendat
RU : 4.90 MB/s
LF : 8.01 MB/s
Supposed Distance = 10 um
position of the target = 10.2 um
micrometer = 8.8 um
Voltage = 7.941 V
nothing has changed. the situation is stable. |
|
45
|
Fri Mar 3 04:15:32 2023 |
mgb | Runs | | General | |
plunger run # 157
Beam dump 2.5 enA
Collimator 1.0 enA
Run Data = /onlineNEDA_00/xData/hil099/run_0035_03-03-2023_00h04m26s/needleRU_i35_0035_0018.caendat
RU : 4.79 MB/s
LF : 7.69 MB/s
Supposed Distance = 10 um
position of the target = 10.2 um
micrometer = 8.9 um
Voltage = 7.94 V
Plunger off set 60 um
Which means we are running 60 um + 10 um (read from position window of plunger) = 70 um. |
|
44
|
Fri Mar 3 03:19:34 2023 |
mgb | Runs | | General | |
plunger run # 147
Beam dump 2.5 enA
Collimator 0.9 enA
Run Data = /onlineNEDA_00/xData/hil099/run_0035_03-03-2023_00h04m26s/needleRU_i35_0035_0014.caendat
RU : 4.90 MB/s
LF : 8.07 MB/s
Supposed Distance = 10 um
position of the target = 10.5 um
micrometer = 9.2 um
Voltage = 7.93 V
Plunger off set 60 um
Which means we are running 60 um + 10 um (read from position window of plunger) = 70 um. |
|
43
|
Fri Mar 3 02:23:45 2023 |
GJ | Problems | | Software | builder gate, TS offsets |
Data from current run - 35, with limited beam current and rates - see a recent post by Güray.
BU level, so what we see in Greware (both online & nearline).
Attached is the fold of Germaniums.
It seems way too large to me.
We are summing up the events and then, not surprisingly, having rubbish gamma-gamma matrices.
The gate is 1500 ns, while Ge are not so far away from each other.
Any fixed time differences should be corrected with LF configuration.
Having all Ge, ACS, and Neda TS-aligned at LF level, BU will do a good job with a reasonable short gate.
We need channel-by-channel TS differences.
The data we took and we are taking now can be recovered in terms of this correction later on.
Marcin can build the events correctly from LF level.
Let's try to do so with as short gates as possible and see again the gamma-gamma matrix and neutron-gated g-g
matrix. |
|
42
|
Fri Mar 3 02:20:46 2023 |
mgb | Runs | | General | |
plunger run # 137
Beam dump 2.5 enA
Collimator 1.0 enA
02:21 /onlineNEDA_00/xData/hil099/run_0035_03-03-2023_00h04m26s/needleRU_i35_0035_0010.caendat
RU : 4.70 MB/s
LF : 7.92 MB/s
Supposed Distance = 10 um
position of the target = 10.7 um
micrometer = 9.8 um
Voltage = 7.89 V
Plunger off set 60 um
Which means we are running 60 um + 10 um (read from position window of plunger) = 70 um. |
|
41
|
Fri Mar 3 01:15:27 2023 |
mgb | Runs | | General | |
plunger run # 126
Earlier: CUP#6 100 enA
Now: CUP#6 50eNA
Beam dump 2.3 enA
Collimator 1.0 enA
RU : 5.44 MB/s
LF : 8.40 MB/s
Supposed Distance = 10 um
position of the target = 10.9 um
micrometer = 10.3 um
Voltage = 7.896 V
Plunger off set 60 um
Which means we are running 60 um + 10 um (read from position window of plunger) = 70 um. |
|
40
|
Fri Mar 3 00:09:19 2023 |
MP, AT | Runs | | | run 35 |
Started after beam current was reduced by a factor of 2
plunger run # 116
Earlier: CUP#6 100 enA
Now: CUP#6 50eNA
Beam dump 1.8 enA
Collimator 0.8 enA
The operator is asked to keep the beam dump current not larger than the present value.
Supposed Distance = 10 um
position of the target = 10 um
micrometer = 11.7 um
Voltage = 7.9 V
Plunger off set 60 um
Which means we are running 60 um + 10 um (read from position window of plunger) = 70 um.
Observed that detectors at theta 143 degrees count most. Is this because they see beam dump? |
|
39
|
Thu Mar 2 23:04:01 2023 |
GJ | Problem Fixed | | Hardware | Connection of the plunger cables, grounding, beam read-out for the operators |
Notes of the measurements with different conditions are attached.
Conclusion:
What is read out by the operators on the blue cable should be multiplied by 7 to get a real value in enA. |
|
38
|
Thu Mar 2 23:01:21 2023 |
A.T. | Runs | | General | Run 34 started |
Run 34 Started (33 was stopped due to acquisition problems)
Plunger Run : 105
Supposed Distance = 10 um
position of the target = 10 um
micrometer = 12.7 um
Voltage = 7.9 V
Plunger off set 60 um
Which means we are running 60 um + 10 um (read from position window of plunger) = 70 um.
at the first 10 min det # 5 was switched off
Ge det # 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
old scalers: 5 2.5 8 5 8.5 3 5 1.5 5 8.5 8.5 7.5 2.7 2.7 5 kHz
new (Grzes) 1.7 1 3.2 1.8 3.6 0.9 1.7 0.45 1.7 3.5 3.2 3.1 1. 1. 1.7 kHz
beam dump current 3nA
det # 5 scaler 7.7 kHz
stoppped 00:02 because beam current was reduced byu a factor of 2 (see note on the next run) |
|
37
|
Thu Mar 2 17:28:21 2023 |
BS | Runs | | | Run 33 Started |
Run 33 Started
Plunger Run : 48
Supposed Distance = 10 um
position of the target = 10 um
micrometer = 6.5 um
Voltage = 7.957 V
Plunger off set 60 um
Which means we are running 60 um + 10 um (read from position window of plunger) = 70 um.
20:50 Observed beam dropped by a factor of 2 (1.5 enA on the beam dump). Asked the operator to improve beam.
run stop 22:53 acquisition problem |
|
36
|
Thu Mar 2 17:25:36 2023 |
BS | Runs | | General | Run 32 Stopped |
Run 32 Stopped |
|
35
|
Thu Mar 2 17:23:53 2023 |
BS | Runs | | General | Plunger Informations |
Plunger Run : 48
Supposed Distance = 10 um
position of the target = 10 um
micrometer = 6.5 um
Voltage = 7.957 V
Plunger off set 60 um
Which means we are running 60 um + 10 um (read from position window of plunger) = 70 um.
|
|
34
|
Thu Mar 2 16:40:45 2023 |
MP | Runs | | General | changing the plunger distance to minimum. |
Run 31 was stopped, because plunger distance is reduced to the mininimal one.
It takes time, in the meantime, after some break, run 32 was started, with no beam. |
|
33
|
Thu Mar 2 16:06:17 2023 |
A.T. | Runs | | General | |
Data
Position = 522.6
Supposed = 520
Plunger run = 32
Micrometer = 525.3
Run Data = /onlineNEDA_00/xData/hil099/run_0031_02-03-2023_11h18m31s/needleRU_i30_0031_0011.caendat
RU = 3.53 Mb/s
LF = 2.40 Mb/s
cables to colimeter are checked and replaced. |
|
32
|
Thu Mar 2 15:15:40 2023 |
mgb | Runs | | General | beam stopped. eagle is opened and run 30 continues |
Data
Position = 522.6
Supposed = 520
Plunger run = 32
Micrometer = 525.3
Run Data = /onlineNEDA_00/xData/hil099/run_0030_02-03-2023_11h18m31s/needleRU_i30_0030_0011.caendat
RU = 3.53 Mb/s
LF = 2.40 Mb/s
beam off and on and off. eagle is opened and run 30 continues
new cable is stucked
Cable test is going on |
|
31
|
Thu Mar 2 14:59:32 2023 |
mgb | Runs | | General | |
Data
Position = 522.6
Supposed = 520
Plunger run = 32
Micrometer = 525.3
Run Data = /onlineNEDA_00/xData/hil099/run_0030_02-03-2023_11h18m31s/needleRU_i30_0030_0011.caendat
RU = 3.53 Mb/s
LF = 2.40 Mb/s |
|
30
|
Thu Mar 2 13:50:50 2023 |
BS | Runs | | General | Run 30 Continueed |
EAGLE is closed now
We gave a break to test the cable connection of target, degrader, beam dump and collimator.
Run 30 continues to collect data, we did not stop it.
But not much usefull data in it. |
|
29
|
Thu Mar 2 12:09:44 2023 |
ost-mgb | Runs | | General | |
beam stop, |
|
28
|
Thu Mar 2 11:19:06 2023 |
BS | Runs | | General | Run 30 Starts |
We hane now g-g trigger started.
Run 30 started |
|
27
|
Thu Mar 2 11:17:54 2023 |
BS | Runs | | | Run 29 stopped |
We will change the trigger and we stopped the run number 29 |
|
26
|
Thu Mar 2 11:14:44 2023 |
ost-mgb | Runs | | General | |
un 29 with single gamma trigger
Plunger feedback system is not connected.
Data
Position = 522.6
Supposed = 520
Plunger run = 32
Micrometer = 525.3
Run Data = /onlineNEDA_00/xData/hil099/run_0029_02-03-2023_10h28m22s/needleRU_i29_0029_0021.caendat
RU = 40.1 Mb/s
LF = 12.5 Mb/s |
|
25
|
Thu Mar 2 10:18:14 2023 |
ost-mgb | Runs | | General | run 29 started |
Run 29 with single gamma trigger
Plunger feedback system is not connected.
Data
Position = 522.6
Supposed = 520
Plunger run = 32
Micrometer = 525.3
Run Data = /onlineNEDA_00/xData/hil099/run_0029_02-03-2023_10h28m22s/needleRU_i29_0029_0002.caendat
RU = 38.5 Mb/s
LF = 12.0 Mb/s
|
|
24
|
Thu Mar 2 09:49:13 2023 |
BS | Runs | | General | run 28 started |
run 28 started |
|
23
|
Thu Mar 2 09:24:47 2023 |
ost-mgb | Runs | Run 27 stopped | General | |
Run 27 stopped |
|
22
|
Thu Mar 2 09:20:17 2023 |
ost-mgb | Runs | | General | Rates |
Run 27 with single gamma trigger
Plunger feedback system is not conected.
Data
Position = 522.6
Supposed = 520
Plunger run = 32
Micrometer = 525.3
Run Data = /onlineNEDA_00/xData/currentRun/needleRU_i27_0027_0043.caendat
RU = 6.25 Mb/s
LF = 4.06 Mb/s
09:15 beam stopped. data saved |
|
21
|
Thu Mar 2 09:05:43 2023 |
DOD | Problems | | | Sulphur on aluminium fusion-evaporation reactions |
Using the data which we've sorted to date, I looked into the gamma-gamma coincidences and have identified a number of nuclei e.g. 50Cr, 52Mn, 55Fe which would be consistent with fusion-evaporation reactions involving the sulphur-32 projectiles and aluminium-27. Such reactions would yield a 59Cu comound system and these channels would be populated as a result of the evaporation of a combination of alphas, protons and neutrons.
These lines are intense and the conicdences are very clear and clean. I think this suggests that the beam is hitting some aluminium components within the plunger chamber. This could be the plunger vessel itself or the target frame perhaps.
There is another interesting observation: some of the identified transitions are emitted from levels which have sub-ps lifetimes. At this plunger distance, we might expect these lines to be fully Doppler shifted as they would decay in-flight well in advance of reaching the stopper. Yet, we observe these lines with their non-Doppler shifted energies suggesting that they are not being emitted in-flight but rather at rest. This might suggest that the 32S+27Al reactions are taking place within some thick piece of aluminium. Some of the lines show signs of having been shifted in energy to some extent which might indicate that not all of the ions are completely stopped. The observed lineshapes seem to be consistent with the short-lived states showing evidence of Doppler shift while the decay of the "longer-lived" states (~9 ps) are very sharp.
I haven't slept for about 24 hours so I may be talking absolute sh*te (famous Scottish word). |
|
20
|
Thu Mar 2 07:40:55 2023 |
ost-dod | Runs | | General | |
Run 27 with single gamma trigger
Plunger feedback system is not conected.
Data
Position = 522.6
Supposed = 520
Plunger run = 32
Micrometer = 525.3
Run Data = /onlineNEDA_00/xData/currentRun/needleRU_i27_0027_0038.caendat
RU = 4.48 Mb/s
LF = 4.07 Mb/s
Nothing really to report. The data rates have been fairly constant since around 4 am. Still observing the frequent sharp minima in the data rates. |
|
19
|
Thu Mar 2 05:33:34 2023 |
ost-dod | Runs | | General | |
Run 27 with single gamma trigger
Plunger feedback system is not conected.
Data
Position = 522.6
Supposed = 520
Plunger run = 32
Micrometer = 525.3
Run Data = /onlineNEDA_00/xData/currentRun/needleRU_i27_0027_0031.caendat
RU = 4.70 Mb/s
LF = 3.20 Mb/s
Nothing really to report. The data rates are slowly decreasing from around 3 am. Still observing the frequent sharp minima in the data rates. |
|
18
|
Thu Mar 2 04:17:40 2023 |
DOD | Runs | | General | |
Run 27 with single gamma trigger
Plunger feedback system is not conected.
Data
Position = 522.6
Supposed = 520
Plunger run = 32
Micrometer = 525.3
Run Data = /onlineNEDA_00/xData/currentRun/needleRU_i27_0027_0027.caendat
RU = 5.10 Mb/s
LF = 3.75 Mb/s
Nothing really to report. The data rates are slowly decreasing from around 3 am. Still observing the frequent sharp minima in the data rates. |
|
17
|
Thu Mar 2 00:30:29 2023 |
BS, DOD | Runs | | General | |
Run 27 with single gamma trigger
Plunger feedback system is not conected.
Data
Position = 522.6
Supposed = 520
Plunger run = 32
Micrometer = 525.3
Run Data = /onlineNEDA_00/xData/currentRun/needleRU_i27_0027_0011.caendat
RU = 5.58 Mb/s
LF = 3.72 Mb/s |
|
16
|
Wed Mar 1 21:59:45 2023 |
MB BS | Other | | General | |
Offset of the plunger is 60 um.
new distcal01_vac_after_opening |
|
15
|
Wed Mar 1 20:10:38 2023 |
BS, DOD | Other | | General | |
Run 26 is going on but not much for the moment in terms of any useful data.
And half of the EAGLE is opened.
20:50 EAGLE closed. |
|
14
|
Wed Mar 1 19:04:37 2023 |
BS | Runs | Run | General | Run 26 Started |
Run 26 Started
Beam 9 enA on the collimator |
|
13
|
Wed Mar 1 16:07:49 2023 |
BS | Runs | | | Run 24 Started |
Run 24 has been started but no beams at the moment.
EAGLE is opened.
Just colecting background. |
|
12
|
Wed Mar 1 16:06:50 2023 |
BS | Runs | | | Run 23 Stopped |
Run 23 Stopped due to some unexpected spikes in the
voltage of collimator.
The plunger did not responde to change distance.
The chamber was opened and observed some yellow spots
seen over the Cd target. |
|
11
|
Wed Mar 1 12:51:33 2023 |
MP | Runs | | Beam | beam on the target |
Beam on the target:
target+stopper+beam dump: 25 enA (1.7 pnA) not stable
5 mm collimator: 0.8 enA
data taking continued with run 0023 |
|
10
|
Wed Mar 1 11:52:48 2023 |
MP | Runs | | | first beam |
Operators tune beam on the target, collecting run 0023, trigger gg. |
|
9
|
Wed Mar 1 00:14:28 2023 |
MP | Other | | Beam | beam energy |
Beam energy measured: 148.2 MeV
Mind that this may be an overestimate (by ~1-2 MeV) |
|
8
|
Tue Feb 28 23:10:36 2023 |
BS | Other | | | What we need to include for Plunger |
Plunger Run :
Micrometer :
Supposed Distance:
Position : |
|
7
|
Tue Feb 28 23:08:35 2023 |
BS | Other | | | SHIFT LIST |
https://docs.google.com/spreadsheets/d/1e2homI9RCYrg369z8aaY3VMIPgapUPOv0zKISsl58vQ/edit?usp=sharing
The data from google sheet obtained 14:17 07/03/23
| Initials |
Name |
Surname |
e-mail |
|
|
|
| DOD |
Dave |
O'Donnell |
|
|
|
|
| GJ |
Grzegorz |
Jaworski |
|
|
|
|
|
|
|
| ÖST |
Ömer Sefa |
Temiz |
|
|
|
|
| BS |
Bahadır |
Saygı |
|
|
|
|
|
| KWL |
Kasia |
Wrzosek-Lipska |
|
|
|
|
| ZCH |
Zuzanna |
Chochulska |
zuzanna.chochulska.stud@pw.edu.pl
|
|
|
|
| MK |
Małgorzata |
Kurach |
malgorzata.kurach.stud@pw.edu.pl
|
|
|
|
| MP |
Michał |
Prędota |
michal.predota.stud@pw.edu.pl
|
|
|
|
|
| EG |
Ernest |
Grodner |
|
|
|
|
| BSK |
Bartosz |
Skura |
bartosz.skura.stud@pw.edu.pl
|
|
|
|
| FS |
Franziskus |
Spee |
|
|
|
|
| MB |
Marcel |
Beckers |
mbeckers@ikp.uni-koeln.de
|
|
|
|
| AK |
Agnieszka |
Korgul |
|
|
|
|
| SP |
Serhii |
Panasenko |
sergey.i.panasenko@gmail.com
|
|
|
|
| AT |
Andrzej |
Tucholski |
|
|
|
|
| KS |
Krzysztof |
Solak |
|
|
|
|
| AF |
Aleksandra |
Fijałkowska |
aleksandra.fijalkowska@fuw.edu.pl
|
|
|
|
|
| MGB |
M. Güray |
Budak |
|
|
|
|
| IK |
István |
Kuti |
kuti@atomki.hu |
|
|
|
| JSP |
Justyna |
Samorajczyk-Pyśk |
samorajczyk@slcj.uw.edu.pl
|
|
|
|
| JD |
James |
Deary |
|
|
|
|
| DW |
Dylan |
White |
|
|
|
|
| IP |
Iwona |
Piętka |
iz.pietka@student.uw.edu.pl
|
|
|
|
| WP |
Wiktor |
Poklepa |
w.poklepa@student.uw.edu.pl
|
|
|
|
|
| KSz |
Klara |
Szlęzak |
k.szlezak@student.uw.edu.pl
|
|
|
|
|
| |
|
|
|
| |
|
|
|
|
|
6
|
Mon Feb 27 12:21:29 2023 |
MP, BS | Runs | | General | List of runs |
A list of runs, to be filled during the experiment is available here:
https://docs.google.com/spreadsheets/d/11tyI5pqYKJ-rMaYLuBIPZCClWz9Vu87W0R5AZc2srd8/edit?usp=sharing |
|
5
|
Mon Feb 27 12:13:03 2023 |
MB | Other | | | Plunger Informations |
Off set of the plunger ~60 um
Distcal file distcal01_vac
|
|
4
|
Mon Feb 27 12:10:24 2023 |
BS | Other | | Target | target |
Support of Target = 1.5 mg/cm2 Ta
Target = 1.0 mg/cm2 Cd-106
Stopper = 10 mg/cm2 Au
Beam Dump = ~60 mg/cm2 Au |
|
3
|
Mon Feb 27 02:49:10 2023 |
GJ | Runs | | General | calibs - 2x 152Eu - run 0 |
Run number: 0
Trigger: g
Start time: Mon Feb 27 02:43:50 2023
Stop time: Mon Feb 27 03:21:01 2023
Two Eu sources hanging in more or less focus points of two partially open halves of EAGLE. |
|
2
|
Sun Feb 26 17:26:45 2023 |
GJ | Other | | General | List of participants |
To be filled in, with affiliation and email.
Presumably, for later publication purposes.
Alphabetically by family name, please.
Budak, Mustafa Guray - Gazi University, mbudak@gazi.edu.tr
Ciemała, Michał - IFJ PAN, Kraków, Poland - Michal.Ciemala@ifj.edu.pl
Deary, James, - University of West of Scotland - james.deary@uws.ac.uk
Fijałkowska, Aleksandra, aleksandra.fijalkowska@fuw.edu.pl
Fransen' Christoph IKP JOELN fransen@ikp.uni-koeln.de
Goasduff, Alain - INFN-LNL alain.goasduff@lnl.infn.it
Grębosz, Jurek - IFJ PAN, Kraków, Poland
Jaworski, Grzegorz - HIL UW, Poland - tatrofil@slcj.uw.edu.pl
O'Donnell, David - University of West of Scotland - david.odonnell@uws.ac.uk
Palacz, Marcin - HIL UW, Poland - palacz@slcj.uw.edu.pl
Piętka, Iwona - Faculty of Physics, UW - iz.pietka@student.uw.edu.pl
Poklepa, Wiktor - UW, Poland, w.poklepa@student.uw.edu.pl
Saygi, Bahadir - Ankara University, Turkey - bahadir.saygi@ankara.edu.tr
Solak, Krzysztof - UW Poland, krzysztof.solak@post.pl
Szlęzak, Klara - UW, Poland, k.szlezak@student.uw.edu.pl
Temiz, Omer Sefa - Ankara University, Turkey - omer.temiz.95@gmail.com
White, Dylan, - University of West of Scotland - dylan.white@uws.ac.uk
|
|
1
|
Sun Feb 26 16:50:56 2023 |
GJ | Other | | General | proposal |
|